OpenLegislation

Division 8.1.8.5.1 Introduction

United Kingdom

Original text. Later amendments are not shown.

  1. (a)

    A propane check serves as a CVS verification to determine if there is a discrepancy in measured values of diluted exhaust gas flow. A propane check also serves as a batch-sampler verification to determine if there is a discrepancy in a batch sampling system that extracts a sample from a CVS, as described in paragraph (f) of this point. Using good engineering judgment and safe practices, this check may be performed using a gas other than propane, such as CO2 or CO. A failed propane check might indicate one or more problems that may require corrective action, as follows:

    1. (i)

      Incorrect analyzer calibration. The FID analyzer shall be re-calibrated, repaired, or replaced;

    2. (ii)

      Leak checks shall be performed on CVS tunnel, connections, fasteners, and HC sampling system according to point 8.1.8.7;

    3. (iii)

      The verification for poor mixing shall be performed in accordance with point 9.2.2;

    4. (iv)

      F1The hydrocarbon contamination verification in the sample system shall be performed as described in point 7.3.1.3;

    5. (v)

      Change in CVS calibration. An in-situ calibration of the CVS flow meter shall be performed as described in point 8.1.8.4;

    6. (vi)

      Other problems with the CVS or sampling verification hardware or software. The CVS system, CVS verification hardware, and software shall be inspected for discrepancies;

  2. (b)

    A propane check uses either a reference mass or a reference flow rate of C3H8 as a tracer gas in a CVS. If a reference flow rate is used, any non-ideal gas behaviour of C3H8 in the reference flow meter shall be accounted for. See section 2 of Annex VII (mass based approach) or section 3 of Annex VII (molar based approach), which describe how to calibrate and use certain flow meters. No ideal gas assumption may be used in point 8.1.8.5 and Annex VII. The propane check compares the calculated mass of injected C3H8 using HC measurements and CVS flow rate measurements with the reference value.

Annotations

Textual amendments

F1

Substituted by Commission Delegated Regulation (EU) 2018/989 of 18 May 2018 amending and correcting Delegated Regulation (EU) 2017/654 supplementing Regulation (EU) 2016/1628 of the European Parliament and of the Council with regard to technical and general requirements relating to emission limits and type-approval for internal combustion engines for non-road mobile machinery (Text with EEA relevance).