  "legislation_title": "Commission Delegated Regulation (EU) 2017/654 of 19 December 2016 supplementing Regulation (EU) 2016/1628 of the European Parliament and of the Council with regard to technical and general requirements relating to emission limits and type-approval for internal combustion engines for non-road mobile machinery",
  "legislation_url": "https://openlegislation.uk/eu-regulation-2017-654",
  "path": "annex/VI/division/8/division/8.1/division/8.1.8/division/8.1.8.5/division/8.1.8.5.5",
  "kind": "division",
  "number": "8.1.8.5.5",
  "heading": "Propane check performance",
  "text": "(a) The propane check shall be performed as follows:\n(i) For batch HC sampling, clean storage media, such as evacuated bags shall be connected;\n(ii) HC measurement instruments shall be operated according to the instrument manufacturer's instructions;\n(iii) If correction for dilution air background concentrations of HC is foreseen, background HC in the dilution air shall be measured and recorded;\n(iv) Any integrating devices shall be zeroed;\n(v) Sampling shall begin and any flow integrators shall be started;\n(vi) C3H8 shall be released at the rate selected. If a reference flow rate of C3H8 is used, the integration of this flow rate shall be started;\n(vii) C3H8 shall be continued to be released until at least enough C3H8 has been released to ensure accurate quantification of the reference C3H8 and the measured C3H8;\n(viii) The C3H8 cylinder shall be shut off and sampling shall continue until it has been accounted for time delays due to sample transport and analyzer response;\n(ix) Sampling shall be stopped and any integrators shall be stopped;\n(b) In case the metering with a critical flow orifice is used, the following procedure may be used for the propane check as the alternative method of point 8.1.8.5.5(a);\n(i) For batch HC sampling, clean storage media, such as evacuated bags shall be connected;\n(ii) HC measurement instruments shall be operated according to the instrument manufacturer's instructions;\n(iii) If correction for dilution air background concentrations of HC is foreseen, background HC in the dilution air shall be measured and recorded;\n(iv) Any integrating devices shall be zeroed;\n(v) The contents of the C3H8 reference cylinder shall be released at the rate selected;\n(vi) Sampling shall begin, and any flow integrators started after confirming that HC concentration is to be stable;\n(vii) The cylinder's contents shall be continued to be released until at least enough C3H8 has been released to ensure accurate quantification of the reference C3H8 and the measured C3H8;\n(viii) Any integrators shall be stopped;\n(ix) The C3H8 reference cylinder shall be shut off.",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eur/2017/654/annex/VI/division/8/division/8.1/division/8.1.8/division/8.1.8.5/division/8.1.8.5.5",
    "retrieved_at": "2026-11-01T14:45:01.864924+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}