# Commission Delegated Regulation (EU) 2017/654 of 19 December 2016 supplementing Regulation (EU) 2016/1628 of the European Parliament and of the Council with regard to technical and general requirements relating to emission limits and type-approval for internal combustion engines for non-road mobile machinery, Division 8.1.8.5.5: Propane check performance

Extent: E+W+S+N.I.

(a) The propane check shall be performed as follows:
(i) For batch HC sampling, clean storage media, such as evacuated bags shall be connected;
(ii) HC measurement instruments shall be operated according to the instrument manufacturer's instructions;
(iii) If correction for dilution air background concentrations of HC is foreseen, background HC in the dilution air shall be measured and recorded;
(iv) Any integrating devices shall be zeroed;
(v) Sampling shall begin and any flow integrators shall be started;
(vi) C3H8 shall be released at the rate selected. If a reference flow rate of C3H8 is used, the integration of this flow rate shall be started;
(vii) C3H8 shall be continued to be released until at least enough C3H8 has been released to ensure accurate quantification of the reference C3H8 and the measured C3H8;
(viii) The C3H8 cylinder shall be shut off and sampling shall continue until it has been accounted for time delays due to sample transport and analyzer response;
(ix) Sampling shall be stopped and any integrators shall be stopped;
(b) In case the metering with a critical flow orifice is used, the following procedure may be used for the propane check as the alternative method of point 8.1.8.5.5(a);
(i) For batch HC sampling, clean storage media, such as evacuated bags shall be connected;
(ii) HC measurement instruments shall be operated according to the instrument manufacturer's instructions;
(iii) If correction for dilution air background concentrations of HC is foreseen, background HC in the dilution air shall be measured and recorded;
(iv) Any integrating devices shall be zeroed;
(v) The contents of the C3H8 reference cylinder shall be released at the rate selected;
(vi) Sampling shall begin, and any flow integrators started after confirming that HC concentration is to be stable;
(vii) The cylinder's contents shall be continued to be released until at least enough C3H8 has been released to ensure accurate quantification of the reference C3H8 and the measured C3H8;
(viii) Any integrators shall be stopped;
(ix) The C3H8 reference cylinder shall be shut off.

---