# Commission Delegated Regulation (EU) 2017/654 of 19 December 2016 supplementing Regulation (EU) 2016/1628 of the European Parliament and of the Council with regard to technical and general requirements relating to emission limits and type-approval for internal combustion engines for non-road mobile machinery, Division 8.1.8.5.6: Evaluation of the propane check

Extent: E+W+S+N.I.

Post-test procedure shall be performed as follows:
(a) If batch sampling has been used, batch samples shall be analyzed as soon as practical;
(b) After analyzing HC, contamination and background shall be corrected for;
(c) Total C3H8 mass based on the CVS and HC data shall be calculated as described in Annex VII, using the molar mass of C3H8, M C3H8, instead of the effective molar mass of HC, M HC;
(d) If a reference mass (gravimetric technique) is used, the cylinder's propane mass shall be determined within ± 0,5 % and the C3H8 reference mass shall be determined by subtracting the empty cylinder propane mass from the full cylinder propane mass. If a critical flow orifice (metering with a critical flow orifice) is used, the propane mass shall be determined as flow rate multiplied by the test time;
(e) The reference C3H8 mass shall be subtracted from the calculated mass. If this difference is within ± 3,0 % of the reference mass, the CVS passes this verification.

---
Source: https://www.legislation.gov.uk/eur/2017/654/annex/VI/division/8/division/8.1/division/8.1.8/division/8.1.8.5/division/8.1.8.5.6 (the official version)
Page: https://openlegislation.uk/eu-regulation-2017-654/annex-VI/division-8/division-8.1/division-8.1.8/division-8.1.8.5/division-8.1.8.5.6
Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives.