Division 8.1.8.6.1 Specifications for differential flow measurement

United Kingdom

Original text. Later amendments are not shown.

For partial flow dilution systems to extract a proportional raw exhaust gas sample, the accuracy of the sample flow qm p is of special concern, if not measured directly, but determined by differential flow measurement as set out in equation (6-20):

qm p = qm dew – qm dw (6-20)

Where:

qm p
  • is the sample mass flow rate of exhaust gas into partial flow dilution system

  • qm dw
  • is the dilution air mass flow rate (on wet basis)

  • qm dew
  • is the diluted exhaust gas mass flow rate on wet basis

  • In this case, the maximum error of the difference shall be such that the accuracy of qm p is within ± 5 % when the dilution ratio is less than 15. It can be calculated by taking root-mean-square of the errors of each instrument.

    Acceptable accuracies of q mp can be obtained by either of the following methods:

    1. (a)

      The absolute accuracies of qm dew and qm dw are ± 0,2 % which guarantees an accuracy of qm p of ≤ 5 % at a dilution ratio of 15. However, greater errors will occur at higher dilution ratios;

    2. (b)

      Calibration of qm dw relative to qm dew is carried out such that the same accuracies for qm p as in (a) are obtained. For details see point 8.1.8.6.2;

    3. (c)

      The accuracy of q mp is determined indirectly from the accuracy of the dilution ratio as determined by a tracer gas, e.g. CO2. Accuracies equivalent to method (a) for q mp are required;

    4. (d)

      The absolute accuracy of qm dew and qm dw is within ± 2 % of full scale, the maximum error of the difference between qm dew and qm dw is within 0,2 % and the linearity error is within ± 0,2 % of the highest qm dew observed during the test.