  "url": "https://openlegislation.uk/eu-regulation-2017-654/annex-VI/division-8/division-8.1/division-8.1.8/division-8.1.8.7/division-8.1.8.7.5",
  "json_url": "https://openlegislation.uk/eu-regulation-2017-654/annex-VI/division-8/division-8.1/division-8.1.8/division-8.1.8.7/division-8.1.8.7.5.json",
  "legislation": "eur/2017/654",
  "legislation_title": "Commission Delegated Regulation (EU) 2017/654 of 19 December 2016 supplementing Regulation (EU) 2016/1628 of the European Parliament and of the Council with regard to technical and general requirements relating to emission limits and type-approval for internal combustion engines for non-road mobile machinery",
  "legislation_url": "https://openlegislation.uk/eu-regulation-2017-654",
  "path": "annex/VI/division/8/division/8.1/division/8.1.8/division/8.1.8.7/division/8.1.8.7.5",
  "kind": "division",
  "number": "8.1.8.7.5",
  "heading": "Vacuum-decay leak test",
  "text": "To perform this test a vacuum shall be applied to the vacuum-side volume of the sampling system and the leak rate of the system shall be observed as a decay in the applied vacuum. To perform this test the vacuum-side volume of the sampling system shall be known to within ± 10 % of its true volume. For this test measurement instruments that meet the specifications of points 8.1 and 9.4 shall also be used.\nA vacuum-decay leak test shall be performed as follows:\n(a) The probe end of the system shall be sealed as close to the probe opening as possible by taking one of the following steps:\n(i) The end of the sample probe shall be capped or plugged;\n(ii) The transfer line at the probe shall be disconnected and the transfer line capped or plugged;\n(iii) A leak-tight valve in-line between a probe and transfer line shall be closed;\n(b) All vacuum pumps shall be operated. A vacuum shall be drawn that is representative of normal operating conditions. In the case of sample bags, it is recommend that the normal sample bag pump-down procedure be repeated twice to minimize any trapped volumes;\n(c) The sample pumps shall be turned off and the system sealed. The absolute pressure of the trapped gas and optionally the system absolute temperature shall be measured and recorded. Sufficient time shall be allowed for any transients to settle and long enough for a leak at 0,5 % to have caused a pressure change of at least 10 times the resolution of the pressure transducer. The pressure and optionally temperature shall be recorded once again;\n(d) The leak flow rate based on an assumed value of zero for pumped-down bag volumes and based on known values for the sample system volume, the initial and final pressures, optional temperatures, and elapsed time shall be calculated. It shall be verified that the vacuum-decay leak flow rate is less than 0,5 % of the system's normal in-use flow rate by means of equation (6-22):\nq V leak = V vac R p 2 T 2 − p 1 T 1 t 2 − t 1\n(6-22)\nWhere:\nqV leak is the vacuum-decay leak rate, mol/s\nV vac is the geometric volume of the vacuum-side of the sampling system, m3\nR is the molar gas constant, J/(mol · K)\np 2 is the vacuum-side absolute pressure at time t 2, Pa\nT 2 is the vacuum-side absolute temperature at time t 2, K\np 1 is the vacuum-side absolute pressure at time t 1, Pa\nT 1 is the vacuum-side absolute temperature at time t 1, K\nt 2 is the time at completion of vacuum-decay leak verification test, s\nt 1 is the time at start of vacuum-decay leak verification test, s",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eur/2017/654/annex/VI/division/8/division/8.1/division/8.1.8/division/8.1.8.7/division/8.1.8.7.5",
    "retrieved_at": "2026-11-01T14:45:01.864924+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}