  "url": "https://openlegislation.uk/eu-regulation-2017-654/annex-VI/division-8/division-8.2/division-8.2.1/division-8.2.1.1/division-8.2.1.1.2",
  "json_url": "https://openlegislation.uk/eu-regulation-2017-654/annex-VI/division-8/division-8.2/division-8.2.1/division-8.2.1.1/division-8.2.1.1.2.json",
  "legislation": "eur/2017/654",
  "legislation_title": "Commission Delegated Regulation (EU) 2017/654 of 19 December 2016 supplementing Regulation (EU) 2016/1628 of the European Parliament and of the Council with regard to technical and general requirements relating to emission limits and type-approval for internal combustion engines for non-road mobile machinery",
  "legislation_url": "https://openlegislation.uk/eu-regulation-2017-654",
  "path": "annex/VI/division/8/division/8.2/division/8.2.1/division/8.2.1.1/division/8.2.1.1.2",
  "kind": "division",
  "number": "8.2.1.1.2",
  "heading": "Constant flows",
  "text": "For any pair of flow meters, the recorded sample and total flow rates or their 1 Hz means shall be used to demonstrate that each flow rate was constant within ± 2,5 % of its respective mean or target flow rate. The following options may be used instead of recording the respective flow rate of each type of meter:\n(a) Critical-flow venturi option. For critical-flow venturis, the recorded venturi-inlet conditions or their 1 Hz means shall be used. It shall be demonstrated that the flow density at the venturi inlet was constant within ± 2,5 % of the mean or target density over each test interval. For a CVS critical-flow venturi, this may be demonstrated by showing that the absolute temperature at the venturi inlet was constant within ± 4 % of the mean or target absolute temperature over each test interval;\n(b) Positive-displacement pump option. The recorded pump-inlet conditions or their 1 Hz means shall be used. It shall be demonstrated that the flow density at the pump inlet was constant within ± 2,5 % of the mean or target density over each test interval. For a CVS pump, this may be demonstrated by showing that the absolute temperature at the pump inlet was constant within ± 2 % of the mean or target absolute temperature over each test interval.",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eur/2017/654/annex/VI/division/8/division/8.2/division/8.2.1/division/8.2.1.1/division/8.2.1.1.2",
    "retrieved_at": "2026-11-01T14:45:01.864924+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}