Division 8.2.4.5 Stabilisation of PM samples

United Kingdom

Original text. Later amendments are not shown.

To stabilise PM samples, they shall be placed in one or more containers that are open to the PM-stabilization environment, which is described in point 9.3.4.3.A PM sample is stabilized as long as it has been in the PM-stabilization environment for one of the following durations, during which the stabilization environment has been within the specifications of point 9.3.4.3:

  1. (a)

    If it is expected that a filter's total surface concentration of PM will be greater than 0,353 μg/mm2, assuming a 400 μg loading on a 38 mm diameter filter stain area, the filter shall be exposed to the stabilization environment for at least 60 minutes before weighing;

  2. (b)

    If it is expected that a filter's total surface concentration of PM will be less than 0,353 μg/mm2, the filter shall be exposed to the stabilization environment for at least 30 minutes before weighing;

  3. (c)

    If a filter's total surface concentration of PM to be expected during the test is unknown, the filter shall be exposed to the stabilization environment for at least 60 minutes before weighing.