A schematic of a PFD system is shown in Figure 6.7. It is a general schematic showing principles of sample extraction, dilution and PM sampling. It is not meant to indicate that all the components described in the Figure are necessary for other possible sampling systems that satisfy the intent of sample collection. Other configurations which do not match these schematics are allowed under the condition that they serve the same purpose of sample collection, dilution, and PM sampling. F1These need to satisfy other criteria such as in points 8.1.8.6 (periodic calibration) and 8.2.1.2 (validation) for varying dilution PFD, and point 8.1.4.5 as well as Table 6.5 (linearity verification) and point 8.1.8.5.7 (verification) for constant dilution PFD.

As shown in Figure 6.7, the raw exhaust gas or the primary diluted flow is transferred from the exhaust pipe EP or from CVS respectively to the dilution tunnel DT through the sampling probe SP and the transfer line TL. The total flow through the tunnel is adjusted with a flow controller and the sampling pump P of the particulate sampling system (PSS). For proportional raw exhaust gas sampling, the dilution air flow is controlled by the flow controller FC1, which may use qm ew (exhaust gas mass flow rate on wet basis) or qm aw (intake air mass flow rate on wet basis) and qm f (fuel mass flow rate) as command signals, for the desired exhaust gas split. The sample flow into the dilution tunnel DT is the difference of the total flow and the dilution air flow. The dilution air flow rate is measured with the flow measurement device FM1, the total flow rate with the flow measurement device of the particulate sampling system. The dilution ratio is calculated from these two flow rates. For sampling with a constant dilution ratio of raw or diluted exhaust gas versus exhaust gas flow (e.g.: secondary dilution for PM sampling), the dilution air flow rate is usually constant and controlled by the flow controller FC1 or dilution air pump.

The dilution air (ambient air, synthetic air, or nitrogen) shall be filtered with a high-efficiency PM air (HEPA) filter.

Components of Figure 6.7:

DAF
  • Dilution air filter

  • DT
  • Dilution tunnel or secondary dilution system

  • EP
  • Exhaust pipe or primary dilution system

  • FC1
  • Flow controller

  • FH
  • Filter holder

  • FM1
  • Flow measurement device measuring the dilution air flow rate

  • P
  • Sampling pump

  • PSS
  • PM sampling system

  • PTL
  • PM transfer line

  • SP
  • Raw or diluted exhaust gas sampling probe

  • TL
  • Transfer line

  • Mass flow rates applicable only for proportional raw exhaust gas sampling PFD:

    qm ew
  • is the exhaust gas mass gas flow rate on wet basis

  • qm aw
  • is the intake air mass flow rate on wet basis

  • qm f
  • is the fuel mass flow rate

    1. Figure 6.7Schematic of partial flow dilution system (total sampling type).

    Annotations

    Textual amendments

    F1

    Substituted by Commission Delegated Regulation (EU) 2018/989 of 18 May 2018 amending and correcting Delegated Regulation (EU) 2017/654 supplementing Regulation (EU) 2016/1628 of the European Parliament and of the Council with regard to technical and general requirements relating to emission limits and type-approval for internal combustion engines for non-road mobile machinery (Text with EEA relevance).