OpenLegislation

Division 9.3.1.2 Transfer lines

United Kingdom

Original text. Later amendments are not shown.

Transfer lines that transport an extracted sample from a probe to an analyzer, storage medium, or dilution system shall be minimized in length by locating analyzers, storage media, and dilution systems as close to the probes as practical. The number of bends in transfer lines shall be minimized and that the radius of any unavoidable bend shall be maximized.