# Commission Delegated Regulation (EU) 2017/654 of 19 December 2016 supplementing Regulation (EU) 2016/1628 of the European Parliament and of the Council with regard to technical and general requirements relating to emission limits and type-approval for internal combustion engines for non-road mobile machinery, Division 9.3.2.3.1.1: Requirements

Extent: E+W+S+N.I.

Sample dryers may be used for removing moisture from the sample in order to decrease the effect of water on gaseous emissions measurement. Sample dryers shall meet the requirements set out in point 9.3.2.3.1.1 and in point 9.3.2.3.1.2. The moisture content 0,8 volume % is used in equation (7-13).
For the highest expected water vapour concentration H m , the water removal technique shall maintain humidity at ≤ 5 g water/kg dry air (or about 0,8 volume % H 2 O), which is 100 % relative humidity at 277,1 K (3,9 °C) and 101,3 kPa. This humidity specification is equivalent to about 25 % relative humidity at 298 K (25 °C) and 101,3 kPa. This may be demonstrated by either:
(a) measuring the temperature at the outlet of the sample dryer; or
(b) measuring humidity at a point just upstream of the CLD; or
(c) performing the verification procedure in point 8.1.12.

---