Division 9.3.2.3.1.2 Type of sample dryers allowed and procedure to estimate moisture content after the dryer
United Kingdom
Either type of sample dryer described in this point may be used.
- (a)
If an osmotic-membrane dryer upstream of any gaseous analyzer or storage medium is used, it shall meet the temperature specifications set out in point 9.3.2.2. The dew point, T dew, and absolute pressure, p total, downstream of an osmotic-membrane dryer shall be monitored. The amount of water shall be calculated as specified in Annex VII by using continuously recorded values of T dew and p total or their peak values observed during a test or their alarm set points. Lacking a direct measurement, the nominal p total is given by the dryer's lowest absolute pressure expected during testing.
- (b)
A thermal chiller upstream of a THC measurement system for compression-ignition engines may not be used. If a thermal chiller upstream of an NO2-to-NO converter or in a sampling system without an NO2-to-NO converter is used, the chiller shall meet the NO2 loss-performance check specified in point 8.1.11.4. The dew point, T dew, and absolute pressure, p total, downstream of a thermal chiller shall be monitored. The amount of water shall be calculated as specified in Annex VII by using continuously recorded values of T dew and p total or their peak values observed during a test or their alarm set points. Lacking a direct measurement, the nominal p total is given by the thermal chiller's lowest absolute pressure expected during testing. If it is valid to assume the degree of saturation in the thermal chiller, T dew based on the known chiller efficiency and continuous monitoring of chiller temperature, T chiller may be calculated. If values of T chiller are not continuously recorded, its peak value observed during a test, or its alarm set point, may be used as a constant value to determine a constant amount of water in accordance with Annex VII. If it is valid to assume that T chiller is equal to T dew, T chiller may be used in lieu of T dew in accordance with Annex VII. If it is valid to assume a constant temperature offset between T chiller and T dew, due to a known and fixed amount of sample reheat between the chiller outlet and the temperature measurement location, this assumed temperature offset value may be factored in into emission calculations. The validity of any assumptions allowed by this point shall be shown by engineering analysis or by data.