Division 9.3.3.4.3 Dilution and temperature control of PM samples
United Kingdom
PM samples shall be diluted at least once upstream of transfer lines in case of a CVS system and downstream in case of PFD system (see point 9.3.3.2 relating to transfer lines). F1Sample temperature shall be controlled to a 320 ± 5 K (47 ± 5 °C) tolerance, as measured anywhere within 200 mm upstream or 200 mm downstream of the PM filter media. The PM sample is intended to be heated or cooled primarily by dilution conditions as specified in point 9.2.1(a).