Division 9.3.4.3 Temperature of the chamber

United Kingdom

Original text. Later amendments are not shown.

The temperature of the chamber (or room) in which the particulate filters are conditioned and weighed shall be maintained to within 295 ± 1 K (22 °C ± 1 °C) during all filter conditioning and weighing. The humidity shall be maintained to a dew point of 282,5 ± 1 K (9,5 °C ± 1 °C) and a relative humidity of 45 % ± 8 %. If the stabilization and weighing environments are separate, the stabilization environment shall be maintained at a tolerance of 295 ± 3 K (22 °C ± 3 °C).