Division 9.4.3.2 Component requirements

United Kingdom

Original text. Later amendments are not shown.

Table 6.8 shows the specifications of transducers of torque, speed, and pressure, sensors of temperature and dew point, and other instruments. The overall system for measuring the given physical and/or chemical quantity shall meet the linearity verification in point 8.1.4. For gaseous emissions measurements, analyzers may be used, that have compensation algorithms that are functions of other measured gaseous components, and of the fuel properties for the specific engine test. Any compensation algorithm shall only provide offset compensation without affecting any gain (that is no bias).

Table 6.8

Recommended performance specifications for measurement instruments

Accuracy and repeatability are all determined with the same collected data, as described in point 9.4.3, and based on absolute values. ‘pt.’ refers to the overall mean value expected at the emission limit; ‘max.’ refers to the peak value expected at the emission limit over the duty cycle, not the maximum of the instrument's range; ‘meas.’ refers to the actual mean measured over the duty cycle.

Measurement InstrumentMeasured quantity symbolComplete SystemRise timeRecording update frequencyAccuracyf1 Repeatability
Engine speed transducern1 s1 Hz means

2,0 % of pt. or

0,5 % of max

1,0 % of pt. or

0,25 % of max

Engine torque transducerT1 s1 Hz means

2,0 % of pt. or

1,0 % of max

1,0 % of pt. or

0,5 % of max

Fuel flow meter

(Fuel totalizer)

5 s

(N/A)

1 Hz

(N/A)

2,0 % of pt. or

1,5 % of max

1,0 % of pt. or

0,75 % of max

Total diluted exhaust gas meter (CVS)

(With heat exchanger before meter)

1 s

(5 s)

1 Hz means

(1 Hz)

2,0 % of pt. or

1,5 % of max

1,0 % of pt. or

0,75 % of max

Dilution air, inlet air, exhaust gas, and sample flow meters1 s1 Hz means of 5 Hz samples

2,5 % of pt. or

1,5 % of max

1,25 % of pt. or

0,75 % of max

Continuous gas analyzer rawx5 s2 Hz

2,0 % of pt. or

2,0 % of meas.

1,0 % of pt. or

1,0 % of meas.

Continuous gas analyzer dilutex5 s1 Hz

2,0 % of pt. or

2,0 % of meas.

1,0 % of pt. or

1,0 % of meas.

Continuous gas analyzerx5 s1 Hz

2,0 % of pt. or

2,0 % of meas.

1,0 % of pt. or

1,0 % of meas.

Batch gas analyzerxN/AN/A

2,0 % of pt. or

2,0 % of meas.

1,0 % of pt. or

1,0 % of meas.

Gravimetric PM balance m PM N/AN/ASee 9.4.110,5 μg
Inertial PM balance m PM 5 s1 Hz

2,0 % of pt. or

2,0 % of meas.

1,0 % of pt. or

1,0 % of meas.

Annotations

Footnotes

f1

Accuracy and repeatability are all determined with the same collected data, as described in point 9.4.3, and based on absolute values. ‘pt.’ refers to the overall mean value expected at the emission limit; ‘max.’ refers to the peak value expected at the emission limit over the duty cycle, not the maximum of the instrument's range; ‘meas.’ refers to the actual mean measured over the duty cycle.