# Commission Delegated Regulation (EU) 2017/654 of 19 December 2016 supplementing Regulation (EU) 2016/1628 of the European Parliament and of the Council with regard to technical and general requirements relating to emission limits and type-approval for internal combustion engines for non-road mobile machinery, Division 9.4.5.4.3: Exhaust gas cooling

Extent: E+W+S+N.I.

Diluted exhaust gas upstream of a dilute flow meter may be cooled, as long as all the following provisions are observed:
(a) PM shall not be sampled downstream of the cooling;
(b) If cooling causes exhaust gas temperatures above 475 K (202 °C) to decrease to below 453 K (180 °C), HC shall not be sampled downstream of the cooling;
(c) If cooling causes aqueous condensation, NOx shall not be sampled downstream of the cooling unless the cooler meets the performance verification in point 8.1.11.4;
(d) If cooling causes aqueous condensation before the flow reaches a flow meter, dew point, T dew and pressure p total shall be measured at the flow meter inlet. These values shall be used in emission calculations in accordance with Annex VII.

---
Source: https://www.legislation.gov.uk/eur/2017/654/annex/VI/division/9/division/9.4/division/9.4.5/division/9.4.5.4/division/9.4.5.4.3 (the official version)
Page: https://openlegislation.uk/eu-regulation-2017-654/annex-VI/division-9/division-9.4/division-9.4.5/division-9.4.5.4/division-9.4.5.4.3
Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives.