# Commission Delegated Regulation (EU) 2017/654 of 19 December 2016 supplementing Regulation (EU) 2016/1628 of the European Parliament and of the Council with regard to technical and general requirements relating to emission limits and type-approval for internal combustion engines for non-road mobile machinery, Division 3.3.2.2: Dew point

Extent: E+W+S+N.I.

If humidity is measured as a dew point, the amount of water in an ideal gas x H2O [mol/mol] shall be obtained by means of equation (7-79):
x H2O = p H2O p abs
(7-79)
Where:
x H2O amount of water in an ideal gas [mol/mol]
p H2O vapour pressure of water at the measured dew point, T sat=T dew [kPa]
p abs wet static absolute pressure at the location of dew point measurement [kPa]

---
Source: https://www.legislation.gov.uk/eur/2017/654/annex/VII/division/3/division/3.3/division/3.3.2/division/3.3.2.2 (the official version)
Page: https://openlegislation.uk/eu-regulation-2017-654/annex-VII/division-3/division-3.3/division-3.3.2/division-3.3.2.2