Division 9 TEST OF ALARMS AND INDICATIONS
United Kingdom
- (a)
The alarms generated from Inland ECDIS equipment itself as well as the passed alarms delivered to the ECDIS by the connected sensors shall be tested.
- (b)
The test procedure in navigation mode shall comprise the following situations:
-
any error in the Inland ECDIS equipment (built-in test equipment — BITE),
-
missing positioning signal,
-
missing radar signal,
-
missing rate of turn signal,
-
missing heading signal,
-
radar map matching not possible,
-
missing AIS signal.
-
- (c)
The test procedure in information mode shall comprise the following situations:
-
any error in the Inland ECDIS equipment (built-in test equipment - BITE),
-
missing positioning signal,
-
missing heading signal,
-
missing AIS signal.
-
The Inland ECDIS manufacturers have to confirm in their system documentation that the system includes those test procedures and signal indicators in information mode.