Division B Specific monitoring rules
United Kingdom
The monitoring of mineral oil refining activities shall be carried out in accordance with section 1 of this Annex for combustion emissions including flue gas scrubbing. The operator may choose to use the mass balance methodology in accordance with Article 25 for the whole refinery or individual process units such as heavy oil gasification or calcinations plants. Where combinations of standard methodology and mass balance are used, the operator shall provide evidence to the competent authority demonstrating the completeness of emissions covered, and that no double counting of emissions occurs.
Emissions from dedicated hydrogen production units shall be monitored in accordance with section 19 of this Annex.
By way of derogation from Article 24 and 25, emissions from catalytic cracker regeneration, other catalyst regeneration and flexi-cokers shall be monitored using a mass balance, taking into account the state of the input air and the flue gas. All CO in the flue gas shall be accounted for as CO2, applying the mass relation: t CO2 = t CO * 1,571. The analysis of input air and flue gases and the choice of tiers shall be in accordance with the provisions of Articles 32 to 35. The specific calculation methodology shall be approved by the competent authority.