Where the anode effect overvoltage is measured, the operator shall use the following equations for the determination of PFC emissions:

  • CF4 emissions [t] = OVC × (AEO/CE) × PrAl × 0,001

  • C2F6 emissions [t] = CF4 emissions × FCF2F6

Where:

OVC
  • Overvoltage coefficient (‘emission factor’) expressed as kg CF4 per tonne of aluminium produced per mV overvoltage;

  • AEO
  • Anode effect overvoltage per cell [mV] determined as the integral of (time × voltage above the target voltage) divided by the time (duration) of data collection;

  • CE
  • Average current efficiency of aluminium production [%];

  • PrAl
  • Annual production of primary Aluminium [t];

  • FCF2F6
  • Weight fraction of C2F6 (t C2F6 / t CF4);

  • The term AEO/CE (Anode effect overvoltage / current efficiency) expresses the time-integrated average anode effect overvoltage [mV overvoltage] per average current efficiency [%].

    Emission factor: The emission factor for CF4 (‘overvoltage coefficient’ OVC) shall express the amount [kg] of CF4 emitted per tonne of aluminium produced per millivolt overvoltage [mV]. The emission factor of C2F6 (weight fraction FC2F6) shall express the amount [t] of C2F6 emitted proportionate to the amount [t] of CF4 emitted.

    Tier 1:: The operator shall apply technology-specific emission factors from Table 2 of this section of Annex IV.

    Tier 2: The operator shall use installation-specific emission factors for CF4 [(kg CF4 / t Al ) / (mV)] and C2F6 [t C2F6/ t CF4] established through continuous or intermittent field measurements. For the determination of those emission factors, the operator shall use the most recent version of the guidance mentioned under Tier 3 of section 4.4.2.4 of the 2006 IPCC Guidelines. The operator shall determine the emission factors with a maximum uncertainty of ± 15 % each.

    The operator shall determine the emission factors at least every three years or earlier where necessary due to relevant changes at the installation. Relevant changes shall include a change in the distribution of anode effect duration or a change in the control algorithm affecting the mix of the types of anode effects or the nature of the anode effect termination routine.

    Table 2

    Technology-specific emission factors related to overvoltage activity data.

    TechnologyEmission factor for CF4[(kg CF4/t Al) / mV]Emission factor for C2F6[t C2F6/ t CF4]
    Centre Worked Prebake (CWPB)1,160,121
    Vertical Stud Søderberg (VSS)N.A.0,053