Division Calculation Method B – Overvoltage Method:
United Kingdom
Where the anode effect overvoltage is measured, the operator shall use the following equations for the determination of PFC emissions:
-
CF4 emissions [t] = OVC × (AEO/CE) × PrAl × 0,001
-
C2F6 emissions [t] = CF4 emissions × FCF2F6
Where:
Overvoltage coefficient (‘emission factor’) expressed as kg CF4 per tonne of aluminium produced per mV overvoltage;
Anode effect overvoltage per cell [mV] determined as the integral of (time × voltage above the target voltage) divided by the time (duration) of data collection;
Average current efficiency of aluminium production [%];
Annual production of primary Aluminium [t];
Weight fraction of C2F6 (t C2F6 / t CF4);
The term AEO/CE (Anode effect overvoltage / current efficiency) expresses the time-integrated average anode effect overvoltage [mV overvoltage] per average current efficiency [%].
Emission factor: The emission factor for CF4 (‘overvoltage coefficient’ OVC) shall express the amount [kg] of CF4 emitted per tonne of aluminium produced per millivolt overvoltage [mV]. The emission factor of C2F6 (weight fraction FC2F6) shall express the amount [t] of C2F6 emitted proportionate to the amount [t] of CF4 emitted.
Tier 1:: The operator shall apply technology-specific emission factors from Table 2 of this section of Annex IV.
Tier 2: The operator shall use installation-specific emission factors for CF4 [(kg CF4 / t Al ) / (mV)] and C2F6 [t C2F6/ t CF4] established through continuous or intermittent field measurements. For the determination of those emission factors, the operator shall use the most recent version of the guidance mentioned under Tier 3 of section 4.4.2.4 of the 2006 IPCC Guidelines. The operator shall determine the emission factors with a maximum uncertainty of ± 15 % each.
The operator shall determine the emission factors at least every three years or earlier where necessary due to relevant changes at the installation. Relevant changes shall include a change in the distribution of anode effect duration or a change in the control algorithm affecting the mix of the types of anode effects or the nature of the anode effect termination routine.
Table 2
Technology-specific emission factors related to overvoltage activity data.
| Technology | Emission factor for CF4[(kg CF4/t Al) / mV] | Emission factor for C2F6[t C2F6/ t CF4] |
|---|---|---|
| Centre Worked Prebake (CWPB) | 1,16 | 0,121 |
| Vertical Stud Søderberg (VSS) | N.A. | 0,053 |