  "legislation_title": "Commission Implementing Regulation (EU) 2018/988 of 27 April 2018 amending and correcting Implementing Regulation (EU) 2017/656 laying down the administrative requirements relating to emission limits and type-approval of internal combustion engines for non-road mobile machinery in accordance with Regulation (EU) 2016/1628 of the European Parliament and of the Council (Text with EEA relevance)",
  "legislation_url": "https://openlegislation.uk/eu-regulation-2018-988",
  "path": "annex/VII",
  "kind": "annex",
  "number": "VII",
  "heading": null,
  "text": "Annex VI to Implementing Regulation (EU) 2017/656 is corrected as follows:\n(1) point 2.6 is replaced by the following:\n‘2.6.\nThe test report may be delivered on paper or in an electronic format agreed between the manufacturer, technical service and approval authority.’;\n(2) Appendix 1 is corrected as follows:\n(i) points 10 to 11.2 are replaced by the following:\n‘10.\nInformation concerning the conduct of the transient test (if applicable)\n10.1.\nCycle (mark cycle with X) to be stated in Table 8:\nTable 8\nTransient test cycle\nNRTC\nLSI-NRTC\n10.2.\nTransient test deterioration factors:\n10.2.1. Deterioration Factor (DF): calculated/fixed\n10.2.2. DF values and the emissions results to be stated in Table 9 or Table 10\n10.3.\nNRTC emission results:\nTable 9\nDF values and the emissions results for NRTC\nDFmult/add\nCO\nHC\nNOx\nHC+NOx\nPM\nPN\nEmissions\nCO (g/kWh)\nHC (g/kWh)\nNOx (g/kWh)\nHC+NOx (g/kWh)\nPM (g/kWh)\nPN (#/kWh)\nCold start\nHot start test result\nwith/without regeneration\nWeighted test result\nk ru/k rd\nmult/add\nWeighted test result with IRAFs\nFinal test result with DF\n10.3.1. Hot cycle CO2 (g/kWh):\n10.3.2. Cycle average NH3 (ppm):\n10.3.3. Cycle work for hot start test (kWh):\n10.3.4. Cycle CO2 for hot start test (g):\n10.4.\nLSI-NRTC emission results\nTable 10\nDF values and the emissions results for LSI- NRTC\nDFmult/add\nCO\nHC\nNOx\nHC+NOx\nPM\nPN\nEmissions\nCO (g/kWh)\nHC (g/kWh)\nNOx (g/kWh)\nHC+NOx (g/kWh)\nPM (g/kWh)\nPN (#/kWh)\ntest result\nwith/without regeneration\nk ru/k rd\nmult/add\nTest result with IRAFs\nFinal test result with DF\n10.4.1. Cycle CO2 (g/kWh):\n10.4.2. Cycle average NH3 (ppm):\n10.4.3. Cycle work (kWh):\n10.4.4. Cycle CO2 (g):\n10.5.\nSampling system used for the transient test:\n10.5.1. Gaseous emissions:\n10.5.2. PM:\n10.5.3. Particle number:\n11.\nFinal emissions results\n11.1.\nCycle emissions results to be stated in Table 11.\nTable 11\nFinal emissions results\nEmissions\nCO(g/kWh)\nHC(g/kWh)\nNOx(g/kWh)\nHC+NOx(g/kWh)\nPM(g/kWh)\nPN(#/kWh)\nTest Cycle (1)\nNRSC final result with DF (2).\nFinal transient test result with DF (3)\n11.2.\nCO2 result (4):\n11.3.\nIn service monitoring reference values (5)\n11.3.1.\nReference work (kWh) (6):\n11.3.2.\nReference CO2 mass (g) (7):’;\n(ii) the explanatory notes to Appendix 1 are replaced by the following:\n‘ Explanatory notes to Appendix 1:\n(Footnote markers, footnotes and explanatory notes not to be stated on the test report)\n(1)\nFor NRSC indicate the cycle noted in point 9.1 (Table 4); for transient test indicate cycle noted in point 10.1 (Table 8).\n(2)\nCopy the “Final test result with DF” results from Table 6.\n(3)\nCopy “Final test result with DF” results from Table 9 or 10, as applicable.\n(4)\nFor an engine type or engine family that is tested on both the NRSC and a transient cycle, indicate the hot cycle CO2 emissions values from the NRTC noted in point 10.3.4 or the CO2 emissions values from the LSI-NRTC noted in point 10.4.4. For an engine only tested on an NRSC indicate the CO2 emissions values given in that cycle noted in point 9.3.3.\n(5)\nOnly applicable to engines of sub-categories NRE-v-5 and NRE-v-6 tested on NRTC.\n(6)\nIndicate the cycle work for hot start test value from the NRTC noted in point 10.3.3.\n(7)\nIndicate the cycle CO2 for hot start test value from the NRTC noted in point 10.3.4.’.",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eur/2018/988/annex/VII",
    "retrieved_at": "2026-11-01T14:44:02.514156+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}