Division 4.4.1.2 The EU fertilising product shall be subjected to the detonation resistance test in a horizontal steel tube under the following conditions (the details of the materials are in point 4.4.3):
United Kingdom
- (a)
seamless steel tube:
- (i)
Tube length: 1 000 mm at least,
- (ii)
Nominal external diameter: 114 mm at least,
- (iii)
Nominal wall thickness: 5 mm at least,
- (i)
- (b)
booster: the type and mass of the booster chosen shall be such as to maximise the detonation pressure applied to the sample in order to determine its susceptibility to the transmission of detonation,
- (c)
temperature of the sample: 15 °C to 25 °C,
- (d)
witness lead cylinders for detecting detonation: 50 mm diameter and 100 mm height,
- (e)
placed at 150 mm intervals and supporting the tube horizontally.
NOTE: The test is to be carried out twice. The test is deemed conclusive if in both tests one or more of the supporting lead cylinders is crushed by less than 5 %.