{
  "url": "https://openlegislation.uk/eu-regulation-2019-2013/annex-IV/division-1",
  "json_url": "https://openlegislation.uk/eu-regulation-2019-2013/annex-IV/division-1.json",
  "legislation": "eur/2019/2013",
  "legislation_title": "Commission Delegated Regulation (EU) 2019/2013 of 11 March 2019 supplementing Regulation (EU) 2017/1369 of the European Parliament and of the Council with regard to energy labelling of electronic displays and repealing Commission Delegated Regulation (EU) No 1062/2010 (Text with EEA relevance)",
  "legislation_url": "https://openlegislation.uk/eu-regulation-2019-2013",
  "path": "annex/IV/division/1",
  "kind": "division",
  "number": "1",
  "heading": "MEASUREMENTS OF ON MODE POWER DEMAND",
  "text": "Measurements of the on mode power demand shall fulfil all of the following general conditions:\n(a)electronic displays shall be measured in the normal configuration;\n(b)measurements shall be made at an ambient temperature of 23 °C +/- 5 °C;\n(c)measurements shall be made using a dynamic broadcast video signal test loops representing typical broadcast content for electronic displays in standard dynamic range (SDR). For the HDR measurement the electronic display must automatically and correctly respond to the HDR metadata in the test loop. The measurement shall be the average power consumed over 10 consecutive minutes;\n(d)measurements shall be made after the electronic display has been in the off-mode or, if an off-mode is not available, in standby mode for a minimum of 1 hour immediately followed by a minimum of 1 hour in the on mode and shall be completed before a maximum of 3 hours in on-mode. The relevant video signal shall be displayed during the entire on mode duration. For electronic displays that are known to stabilise within 1 hour, these durations may be reduced if the resulting measurement can be shown to be within 2 % of the results that would otherwise be achieved using the durations described here;\n(e)where ABC is available, measurements shall be made with it switched off. If ABC cannot be switched off, then the measurements shall be performed in an ambient light condition of 100 lux measured at the ABC sensor.",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eur/2019/2013/annex/IV/division/1",
    "retrieved_at": "2026-11-01T14:43:00.602166+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}