  "url": "https://openlegislation.uk/eu-regulation-2019-2015/annex-V/division-1/division-1.1",
  "json_url": "https://openlegislation.uk/eu-regulation-2019-2015/annex-V/division-1/division-1.1.json",
  "legislation": "eur/2019/2015",
  "legislation_title": "Commission Delegated Regulation (EU) 2019/2015 of 11 March 2019 supplementing Regulation (EU) 2017/1369 of the European Parliament and of the Council with regard to energy labelling of light sources and repealing Commission Delegated Regulation (EU) No 874/2012 (Text with EEA relevance)",
  "legislation_url": "https://openlegislation.uk/eu-regulation-2019-2015",
  "path": "annex/V/division/1/division/1.1",
  "kind": "division",
  "number": "1.1",
  "heading": "Pursuant to point 1(b) of Article 3, the supplier shall enter into the product database the information as set out in Table 3, including when the light source is a part in a containing product.",
  "text": "Table 3\nProduct information sheet\nchanges to these items shall not be considered relevant for the purposes of point 4 of Article 4 of Regulation (EU) 2017/1369.\nif the product database automatically generates the definitive content of this cell the supplier shall not enter these data.\n‘-’: not applicable;\n‘yes’: An equivalence claim involving the power of a replaced light source type may be given only:\nfor directional light sources, if the light source type is listed in Table 4 and if the luminous flux of the light source in a 90 ° cone (Φ90°) is not lower than the corresponding reference luminous flux in Table 4. The reference luminous flux shall be multiplied by the correction factor in Table 5. For LED light sources, it shall be in addition multiplied by the correction factor in Table 6;\nfor non-directional light sources, the claimed equivalent incandescent light source power (rounded to 1 W) shall be that corresponding in Table 7 to the luminous flux of the light source.\nThe intermediate values of both the luminous flux and the claimed equivalent light source power (rounded to the nearest 1 W) shall be calculated by linear interpolation between the two adjacent values.\n‘-’: not applicable;\n‘yes’: Claim that a LED light source replaces a fluorescent light source without integrated ballast of a particular wattage. This claim may be made only if:\nthe luminous intensity in any direction around the tube axis does not deviate by more than 25 % from the average luminous intensity around the tube; and\nthe luminous flux of the LED light source is not lower than the luminous flux of the fluorescent light source of the claimed wattage. The luminous flux of the fluorescent light source shall be obtained by multiplying the claimed wattage with the minimum luminous efficacy value corresponding to the fluorescent light source in Table 8; and\nthe wattage of the LED light source is not higher than the wattage of the fluorescent light source it is claimed to replace.\nThe technical documentation file shall provide the data to support such claims.\nSupplier’s name or trade mark:\nSupplier’s address :\nModel identifier:\nType of light source:\nLighting technology used:\n[HL/LFL T5 HE/LFL T5 HO/CFLni/other FL/HPS/MH/other HID/LED/OLED/mixed/other]\nNon-directional or directional:\n[NDLS/DLS]\nMains or non-mains:\n[MLS/NMLS]\nConnected light source (CLS):\n[yes/no]\nColour-tuneable light source:\n[yes/no]\nEnvelope:\n[no/second/non-clear]\nHigh luminance light source:\n[yes/no]\nAnti-glare shield:\n[yes/no]\nDimmable:\n[yes/only with specific dimmers/no]\nProduct parameters\nParameter\nValue\nParameter\nValue\nGeneral product parameters:\nEnergy consumption in on-mode (kWh/1 000 h)\nx\nEnergy efficiency class\n[A/B/C/D/E/F/G]\nUseful luminous flux (Φuse), indicating if it refers to the flux in a sphere (360°), in a wide cone (120°) or in a narrow cone (90°)\nx in [sphere/wide cone/narrow cone]\nCorrelated colour temperature, rounded to the nearest 100 K, or the range of correlated colour temperatures, rounded to the nearest 100 K, that can be set\n[x/x…x]\nOn-mode power (Pon), expressed in W\nx,x\nStandby power (Psb), expressed in W and rounded to the second decimal\nx,xx\nNetworked standby power (Pnet) for CLS, expressed in W and rounded to the second decimal\nx,xx\nColour rendering index, rounded to the nearest integer, or the range of CRI-values that can be set\n[x/x…x]\nOuter dimensions without separate control gear, lighting control parts and non-lighting control parts, if any (millimetre)\nHeight\nx\nSpectral power distribution in the range 250 nm to 800 nm, at full-load\n[graphic]\nWidth\nx\nDepth\nx\nClaim of equivalent power\n[yes/-]\nIf yes, equivalent power (W)\nx\nChromaticity coordinates (x and y)\n0,xxx\n0,xxx\nParameters for directional light sources:\nPeak luminous intensity (cd)\nx\nBeam angle in degrees, or the range of beam angles that can be set\n[x/x…x]\nParameters for LED and OLED light sources:\nR9 colour rendering index value\nx\nSurvival factor\nx,xx\nthe lumen maintenance factor\nx,xx\nParameters for LED and OLED mains light sources:\ndisplacement factor (cos φ1)\nx,xx\nColour consistency in McAdam ellipses\nx\nClaims that an LED light source replaces a fluorescent light source without integrated ballast of a particular wattage.\n[yes/-]\nIf yes then replacement claim (W)\nx\nFlicker metric (Pst LM)\nx,x\nStroboscopic effect metric (SVM)\nx,x\nTable 4\nReference luminous flux for equivalence claims\nExtra-low voltage reflector type\nType\nPower (W)\nReference Φ90° (lm)\nMR11 GU4\n20\n160\n35\n300\nMR16 GU 5.3\n20\n180\n35\n300\n50\n540\nAR111\n35\n250\n50\n390\n75\n640\n100\n785\nMains-voltage blown glass reflector type\nType\nPower (W)\nReference Φ90° (lm)\nR50/NR50\n25\n90\n40\n170\nR63/NR63\n40\n180\n60\n300\nR80/NR80\n60\n300\n75\n350\n100\n580\nR95/NR95\n75\n350\n100\n540\nR125\n100\n580\n150\n1 000\nMains-voltage pressed glass reflector type\nType\nPower (W)\nReference Φ90° (lm)\nPAR16\n20\n90\n25\n125\n35\n200\n50\n300\nPAR20\n35\n200\n50\n300\n75\n500\nPAR25\n50\n350\n75\n550\nPAR30S\n50\n350\n75\n550\n100\n750\nPAR36\n50\n350\n75\n550\n100\n720\nPAR38\n60\n400\n75\n555\n80\n600\n100\n760\n120\n900\nTable 5\nMultiplication factors for lumen maintenance\nLight source type\nLuminous flux multiplication factor\nHalogen light sources\n1\nFluorescent light sources\n1,08\nLED light sources\n1 + 0,5 × (1 - LLMF)\nwhere LLMF is the lumen maintenance factor at the end of the declared lifetime\nTable 6\nMultiplication factors for LED light sources\nLED light source beam angle\nLuminous flux multiplication factor\n20° ≤ beam angle\n1\n15° ≤ beam angle < 20°\n0,9\n10° ≤ beam angle < 15°\n0,85\nbeam angle < 10°\n0,8\nTable 7\nEquivalence claims for non-directional light sources\nRated light source luminous flux Φ (lm)\nClaimed equivalent incandescent light source power (W)\n136\n15\n249\n25\n470\n40\n806\n60\n1 055\n75\n1 521\n100\n2 452\n150\n3 452\n200\nTable 8\nMinimum efficacy values for T8 and T5 light sources\nT8 (26 mm Ø)\nT5 (16 mm Ø)High Efficiency\nT5 (16 mm Ø)High Output\nClaimed equivalent power (W)\nMinimum luminous efficacy (lm/W)\nClaimed equivalent power (W)\nMinimum luminous efficacy (lm/W)\nClaimed equivalent power (W)\nMinimum luminous efficacy (lm/W)\n15\n63\n14\n86\n24\n73\n18\n75\n21\n90\n39\n79\n25\n76\n28\n93\n49\n88\n30\n80\n35\n94\n54\n82\n36\n93\n80\n77\n38\n87\n58\n90\n70\n89\nFor light sources that can be tuned to emit light at full-load with different characteristics, the values of parameters that vary with these characteristics shall be reported at the reference control settings.\nIf the light source is no longer placed on the EU market, the supplier shall put in the product database the date (month, year) when the placing on the EU market stopped.",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [
    {
      "type": "footnote",
      "label": "f1",
      "text": "changes to these items shall not be considered relevant for the purposes of point 4 of Article 4 of Regulation (EU) 2017/1369."
    },
    {
      "type": "footnote",
      "label": "f2",
      "text": "if the product database automatically generates the definitive content of this cell the supplier shall not enter these data."
    },
    {
      "type": "footnote",
      "label": "f3",
      "text": "‘-’: not applicable; ‘yes’: An equivalence claim involving the power of a replaced light source type may be given only: for directional light sources, if the light source type is listed in Table 4 and if the luminous flux of the light source in a 90 ° cone (Φ90°) is not lower than the corresponding reference luminous flux in Table 4. The reference luminous flux shall be multiplied by the correction factor in Table 5. For LED light sources, it shall be in addition multiplied by the correction factor in Table 6; for non-directional light sources, the claimed equivalent incandescent light source power (rounded to 1 W) shall be that corresponding in Table 7 to the luminous flux of the light source. The intermediate values of both the luminous flux and the claimed equivalent light source power (rounded to the nearest 1 W) shall be calculated by linear interpolation between the two adjacent values."
    },
    {
      "type": "footnote",
      "label": "f4",
      "text": "‘-’: not applicable; ‘yes’: Claim that a LED light source replaces a fluorescent light source without integrated ballast of a particular wattage. This claim may be made only if: the luminous intensity in any direction around the tube axis does not deviate by more than 25 % from the average luminous intensity around the tube; and the luminous flux of the LED light source is not lower than the luminous flux of the fluorescent light source of the claimed wattage. The luminous flux of the fluorescent light source shall be obtained by multiplying the claimed wattage with the minimum luminous efficacy value corresponding to the fluorescent light source in Table 8; and the wattage of the LED light source is not higher than the wattage of the fluorescent light source it is claimed to replace. The technical documentation file shall provide the data to support such claims."
    }
  ],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eur/2019/2015/annex/V/division/1/division/1.1",
    "retrieved_at": "2026-11-01T14:43:00.426575+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}