  "url": "https://openlegislation.uk/eu-regulation-2019-2016/annex-IV/division-4",
  "json_url": "https://openlegislation.uk/eu-regulation-2019-2016/annex-IV/division-4.json",
  "legislation": "eur/2019/2016",
  "legislation_title": "Commission Delegated Regulation (EU) 2019/2016 of 11 March 2019 supplementing Regulation (EU) 2017/1369 of the European Parliament and of the Council with regard to energy labelling of refrigerating appliances and repealing Commission Delegated Regulation (EU) No 1060/2010 (Text with EEA relevance)",
  "legislation_url": "https://openlegislation.uk/eu-regulation-2019-2016",
  "path": "annex/IV/division/4",
  "kind": "division",
  "number": "4",
  "heading": "Determination of the standard annual energy consumption (SAE):",
  "text": "(a)For all refrigerating appliances:\nSAE, expressed in kWh/a, and rounded to two decimal places, is calculated as follows:\nSAE = C × D × Σ n c = 1 A c × B c × [V c /V] × (N c + V × r c × M c )\nwhere\nc is the index number for a compartment type ranging from 1 to n, with n the total number of compartment types;\nVc , expressed in dm3 or litres and rounded to the first decimal place is the compartment volume;\nV, expressed in dm3 or litres and rounded to the nearest integer is the volume with V≤∑c=1nVc;\nrc, Nc, Mc and C are modelling parameters specific to each compartment with values as set out in Table 4; and\nAc, Bc and D are the compensation factors with values as set out in Table 5.\nWhen carrying out the calculations above, for the variable temperature compartments, the compartment type with the lowest target temperature for which it is declared suitable is chosen.\n(b)Modelling parameters per compartment type for the calculation of SAE:\nThe modelling parameters are set out in Table 4.\nTable 4\nThe values of the modelling parameters per compartment type\nrc = (Ta-Tc)/20; with Ta = 24 °C and Tc with values as set out in Table 3.\nC for combi appliances with 3-or 4-star compartments is determined as follows:\nwhere frzf is the 3- or 4-star compartment volume Vfr as a fraction of V with frzf = Vfr/V:\nif frzf ≤ 0,3 then C =1,3 + 0,87 × frzf;\nelse if 0,3 < frzf < 0,7 then C =1,87 - 1,0275 × frzf;\nelse C =1,15.\nCompartment type\nrc\nNc\nMc\nC\nPantry\n0,35\n75\n0,12\nbetween 1,15 and 1,56 for combi appliances with 3-or 4-star compartments, 1,15 for other combi appliances, 1,0 for other refrigerating appliances\nWine storage\n0,6\nCellar\n0,6\nFresh food\n1,0\nChill\n1,1\n138\n0,12\n0-star & ice-making\n1,2\n138\n0,15\n1-star\n1,5\n2-star\n1,8\n3-star\n2,1\nFreezer (4-star)\n2,1\n(c)Compensation factors per compartment type in the calculation of SAE:\nThe compensation factors are set out in Table 5.\nTable 5\nThe values of the compensation factors per compartment type\nnumber of external doors or compartments, whichever is lowest.\nCompartment type\nAc\nBc\nD\nManual defrost\nAuto-defrost\nFreestanding appliance\nBuilt-in appliance\n≤ 2\n3\n4\n> 4\nPantry\n1,0\n1,0\n1,02\n1,0\n1,02\n1,035\n1,05\nWine storage\nCellar\nFresh food\nChill\n1,03\n0-star & ice-making\n1,0\n1,1\n1,05\n1-star\n2-star\n3-star\nFreezer (4-star)",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [
    {
      "type": "X",
      "label": "X1",
      "text": "Substituted by Corrigendum to Commission Delegated Regulation (EU) 2019/2016 of 11 March 2019 supplementing Regulation (EU) 2017/1369 of the European Parliament and of the Council with regard to energy labelling of refrigerating appliances and repealing Commission Delegated Regulation (EU) No 1060/2010 (Official Journal of the European Union L 315 of 5 December 2019)."
    },
    {
      "type": "footnote",
      "label": "f1",
      "text": "rc = (Ta-Tc)/20; with Ta = 24 °C and Tc with values as set out in Table 3."
    },
    {
      "type": "footnote",
      "label": "f2",
      "text": "C for combi appliances with 3-or 4-star compartments is determined as follows:where frzf is the 3- or 4-star compartment volume Vfr as a fraction of V with frzf = Vfr/V:if frzf ≤ 0,3 then C =1,3 + 0,87 × frzf;else if 0,3 < frzf < 0,7 then C =1,87 - 1,0275 × frzf;else C =1,15."
    },
    {
      "type": "footnote",
      "label": "f3",
      "text": "number of external doors or compartments, whichever is lowest."
    }
  ],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eur/2019/2016/annex/IV/division/4",
    "retrieved_at": "2026-11-01T14:43:00.340803+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}