# Commission Regulation (EU) 2019/2024 of 1 October 2019 laying down ecodesign requirements for refrigerating appliances with a direct sales function pursuant to Directive 2009/125/EC of the European Parliament and of the Council (Text with EEA relevance), Division 1: General conditions for testing:

Extent: E+W+S+N.I.

(a) the ambient conditions shall correspond to Set 1, except for ice-cream freezers and gelato-scooping cabinets which shall be tested in ambient conditions corresponding to Set 2, as set out in Table 3;
(b) where a compartment can be set to different temperatures, it shall be tested at the lowest operating temperature;
(c) refrigerated vending machines with compartments with variable volumes shall be tested with the net volume of the compartment with the highest operating temperature adjusted to its minimum net volume;
(d) for beverage coolers, the specified cooling speed shall be according to the half reload recovery time.
Table 3
Ambient conditions
Dry bulb temperature, °C
Relative humidity, %
Dew point, °C
Water vapour mass in dry air, g/kg
Set 1
25
60
16,7
12,0
Set 2
30
55
20,0
14,8

---
Source: https://www.legislation.gov.uk/eur/2019/2024/annex/III/division/1 (the official version)
Page: https://openlegislation.uk/eu-regulation-2019-2024/annex-III/division-1
Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives.