  "url": "https://openlegislation.uk/eu-regulation-2019-424/annex-II/division-1/division-1.1/division-1.1.2",
  "json_url": "https://openlegislation.uk/eu-regulation-2019-424/annex-II/division-1/division-1.1/division-1.1.2.json",
  "legislation": "eur/2019/424",
  "legislation_title": "Commission Regulation (EU) 2019/424 of 15 March 2019 laying down ecodesign requirements for servers and data storage products pursuant to Directive 2009/125/EC of the European Parliament and of the Council and amending Commission Regulation (EU) No 617/2013 (Text with EEA relevance)",
  "legislation_url": "https://openlegislation.uk/eu-regulation-2019-424",
  "path": "annex/II/division/1/division/1.1/division/1.1.2",
  "kind": "division",
  "number": "1.1.2",
  "heading": null,
  "text": "From 1 January 2023, for servers and online data storage products, with the exception of direct current servers and of direct current data storage products, the PSU efficiency at 10 %, 20 %, 50 % and 100 % of the rated load level and the power factor at 50 % of the rated load level shall not be less than the values reported in Table 2.\nTable 2\nMinimum PSU efficiency and power factor requirements from 1 January 2023\nMinimum PSU efficiency\nMinimum power factor\n% of rated load\n10 %\n20 %\n50 %\n100 %\n50 %\nMulti output\n—\n90 %\n94 %\n91 %\n0,95\nSingle output\n90 %\n94 %\n96 %\n91 %\n0,95",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eur/2019/424/annex/II/division/1/division/1.1/division/1.1.2",
    "retrieved_at": "2026-11-01T14:43:31.140003+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}