OpenLegislation

Division 3.5.3.1 Inland ship static and voyage related data (Inland specific Message FI 10)

United Kingdom

Original text. Later amendments are not shown.

This message shall be used by inland vessels only, to broadcast vessel static and voyage related data in addition to message 5. The message shall be sent with binary message 8 as soon as possible (from the AIS point of view) after message 5.

Table 3.4

Inland vessel data report

Shall be set to 0 if no type approved sensor (e.g. gyro) is connected to the transponder.

ParameterNumber of bitsDescription
Message ID6Identifier for message 8; always 8
Repeat indicator2

Used by the repeater to indicate how many times a message has been repeated.

0-3; Default = 0; 3 = do not repeat any more

Source ID30MMSI number
Spare2Not used, shall be set to zero. Reserved for future use
Binary dataApplication identifier16DAC = 200, FI = 10
Unique European vessel identification number (ENI)48

8*6 Bit ASCII characters

00000000 = ENI not assigned = default

Length of vessel/convoy131 — 8 000 (rest not to be used) length of vessel/convoy in 1/10 m 0 = default
Beam of vessel/convoy101 — 1 000 (rest not to be used) beam of vessel/convoy in 1/10 m; 0 = default
Vessel and convoy type14

Numeric vessel and convoy type as described in Appendix C

0 = not available = default

Dangerous cargo indication3Number of blue cones/lights 0 — 3; 4 = B-Flag, 5 = default = unknown
Maximum present static draught111 — 2 000 (rest not used) draught in 1/100 m, 0 = default = unknown
Loaded/unloaded21 = loaded, 2 = unloaded, 0 = not available/default, 3 shall not be used
Quality of speed information11 = high, 0 = low/GNSS = defaultf1
Quality of course information11 = high, 0 = low/GNSS = default
Quality of heading information11 = high, 0 = low = default
Spare8Not used, shall be set to zero. Reserved for future use
Total 168 Occupies one slot

Annotations

Footnotes

f1

Shall be set to 0 if no type approved sensor (e.g. gyro) is connected to the transponder.