  "url": "https://openlegislation.uk/eu-regulation-2020-1170/annex/division-3",
  "json_url": "https://openlegislation.uk/eu-regulation-2020-1170/annex/division-3.json",
  "legislation": "eur/2020/1170",
  "legislation_title": "Commission Implementing Regulation (EU) 2020/1170 of 16 July 2020 on design, construction and performance requirements and testing standards for marine equipment and repealing Implementing Regulation (EU) 2019/1397 (Text with EEA relevance)",
  "legislation_url": "https://openlegislation.uk/eu-regulation-2020-1170",
  "path": "annex/division/3",
  "kind": "division",
  "number": "3",
  "heading": "Fire protection equipment",
  "text": "Number and item designation\nRegulation SOLAS 74 as amended, and the relevant resolutions and circulars of the IMO, as applicable\nTesting standards\nModules for conformity assessment\nFirst placing on the market\nLast placing on board\n1\n2\n3\n4\n5\n6\nMED/3.1\nPrimary decks covering\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/4,\nSOLAS 74 Reg. II-2/6,\nSOLAS 74 Reg. X/3.\nIMO Res.MSC.307(88)-(2010 FTP Code), as amended.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/4,\nSOLAS 74 Reg. II-2/6,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7.\nMED/3.2\nPortable fire extinguishers\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/10,\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.98(73)-(FSS Code) 4.\nEN 3-7:2004 incl. A1:2007,\nEN 3-8:2006 incl. AC:2007,\nEN 3-9:2006 incl. AC:2007,\nEN 3-10:2009.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/4,\nSOLAS 74 Reg. II-2/10,\nSOLAS 74 Reg. II-2/18,\nSOLAS 74 Reg. II-2/19,\nSOLAS 74 Reg. II-2/20,\nIMO Res.A.951(23),\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 4,\nIMO Res.MSC.391(95)-(IGF Code) 11,\nIMO MSC/Circ.1239,\nIMO MSC/Circ.1275.\nMED/3.3a\nFire-fighter's outfit: protective clothing (close proximity clothing):\nProtective non reflective clothing for firefighting.\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/10,\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.98(73)-(FSS Code) 3.\nEN 469:2005 incl. A1:2006 and AC:2006.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/10,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 3.\nMED/3.3b\nFire-fighter's outfit: protective clothing (close proximity clothing):\nProtective clothing for firefighting: Reflective clothing for specialised fire-fighting.\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/10,\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.98(73)-(FSS Code) 3.\nEN 1486:2007.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/10,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 3.\nMED/3.3c\nFire-fighter's outfit: protective clothing (close proximity clothing):\nProtective clothing for firefighting: Protective clothing with a reflective outer surface.\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/10,\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.98(73)-(FSS Code) 3.\nISO 15538:2001.\nNote: Level 2.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/10,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 3.\nMED/3.4\nFire-fighter's outfit: boots\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/10,\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.98(73)-(FSS Code) 3.\nEN 15090:2012.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/10,\nSOLAS 74 Reg. II-2/15,\nIMO Res.MSC.4(48)-(IBC Code) 11,\nIMO Res.MSC.5(48)-(IGC Code) 11\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 3.\nMED/3.5\nFire-fighter's outfit: gloves\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/10,\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.98(73)-(FSS Code) 3.\nEN 659:2003 incl. A1:2008 and AC:2009.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/10,\nSOLAS 74 Reg. II-2/15,\nIMO Res.MSC.4(48)-(IBC Code) 11,\nIMO Res.MSC.5(48)-(IGC Code) 11,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 3.\nMED/3.6\nFire-fighter's outfit: helmet\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/10,\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.98(73)-(FSS Code) 3.\nEN 443:2008.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/10,\nSOLAS 74 Reg. II-2/15,\nIMO Res.MSC.4(48)-(IBC Code) 11,\nIMO Res.MSC.5(48)-(IGC Code) 11,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 3.\nMED/3.7\nSelf-contained compressed-air-operated breathing apparatus\nNote: For use in accidents involving dangerous goods a positive pressure type mask is required.\n(Refer to item 7.1)\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/10,\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.98(73)-(FSS Code) 3.\nISO 23269-2:2011 (firefighting - maritime use only).\nType 1 mask shall not be used in either MED/3.7 or MED/7.1.\nNote: Associated fireproof lifeline requested by ISO 23269 § 4.28 shall be MED certified as item MED 3.44 and used in conjunction with the breathing apparatus and capable of being attached by means of a snap-hook to the harness of the apparatus or to a separate belt in order to prevent the breathing apparatus becoming detached when the lifeline is operated.\nThe breathing apparatus module B shall indicate the MED fireproof lifeline as mandatory combined component.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/10,\nSOLAS 74 Reg. II-2/15,\nSOLAS 74 Reg. II-2/19,\nIMO Res.MSC.4(48)-(IBC Code) 11,\nIMO Res.MSC.5(48)-(IGC Code) 11,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 3,\nIMO MSC.1/Circ.1499,\nIMO MSC.1/Circ.1555.\nMED/3.8\nCompressed air line breathing apparatus\nRow 1 of 2\nType approval requirements\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nNote: This equipment is only for high speed craft built under provisions of the 1994 HSC Code.\nEN 14593-1:2005.\nOr:\nEN 14594:2005 incl. AC:2005.\nB+D\nB+E\nB+F\n13.3.2021\n(II)\nCarriage and performance requirements\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nMED/3.8\nCompressed air line breathing apparatus\nRow 2 of 2\nType approval requirements\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nNote: This equipment is only for high speed craft built under provisions of the 1994 HSC Code.\nEN 14593-1:2018.\nOr:\nEN 14594:2018.\nB+D\nB+E\nB+F\n13.9.2019\nCarriage and performance requirements\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nMED/3.9\nSprinkler systems components for accommodation spaces, service spaces and control stations equivalent to that referred to in SOLAS 74 Reg. II-2/12 (limited to nozzles and their performance).\n(Nozzles for fixed sprinkler systems, for high speed craft (HSC) are included under this item).\nNote: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied.\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/7,\nSOLAS 74 Reg. II-2/10,\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.98(73)-(FSS Code) 8.\nIMO Res. A.800(19),as amended.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/7,\nSOLAS 74 Reg. II-2/9,\nSOLAS 74 Reg. II-2/10,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.44(65),\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 8,\nIMO MSC/Circ.912,\nIMO MSC/Circ. 1556.\nMED/3.10\nNozzles for fixed pressure water spraying fire extinguishing systems for machinery spaces and cargo pump-rooms\nNote: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied.\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/10,\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.98(73)-(FSS Code) 7.\nIMO MSC/Circ.1165, as amended.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/10,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 7,\nIMO Res.MSC.391(95)-(IGF Code) 11),\nIMO MSC.1/Circ.1313.\nMED/3.11a\n'A' & 'B' Class divisions fire integrity:\n'A' class divisions.\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/3.2,\nIMO MSC/Circ.1120.\nIMO Res.MSC.307(88)-(2010 FTP Code), as amended,\nIMO MSC.1/Circ.1435.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/3.2.\nSOLAS 74 Reg. II-2/9,\nIMO MSC/Circ.1120,\nIMO MSC.1/Circ.1434.\nMED/3.11b\n'A' & 'B' Class divisions fire integrity:\n'B' class divisions.\nNote: Excludes restricted B-Class divisions/doors.\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/3.4,\nIMO MSC/Circ.1120.\nIMO Res.MSC.307(88)-(2010 FTP Code), as amended.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/3.4,\nSOLAS 74 Reg. II-2/9,\nIMO MSC/Circ.1120,\nIMO MSC.1/Circ.1581.\nMED/3.12\nDevices to prevent the passage of flame into the cargo tanks in tankers\nRow 1 of 2\nType approval requirements\nSOLAS 74 Reg. II-2/4,\nSOLAS 74 Reg. II-2/16.\n(a) P/V valves:\nIMO MSC/Circ.677, as amended,\nEN ISO 16852:2010,\nISO 15364:2016.\n(b) Flame arresters:\nIMO MSC/Circ.677, as amended,\nEN ISO 16852:2010.\n(c) Detonation flame arresters:\nIMO MSC/Circ.677, as amended.\nEN ISO 16852:2010.\n(d) High velocity vent valves:\nIMO MSC/Circ.677, as amended,\nEN ISO 16852:2010,\nISO 15364:2016.\nFor equipment other than valves:\nB+D\nB+E\nB+F\nFor valves:\nB+F\n23.5.2019\n(III)\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/4,\nSOLAS 74 Reg. II-2/16,\nIMO Res.MSC.98(73)-(FSS Code) 15.\nMED/3.12\nDevices to prevent the passage of flame into the cargo tanks in tankers\nRow 2 of 2\nType approval requirements\nSOLAS 74 Reg. II-2/4,\nSOLAS 74 Reg. II-2/16.\n(a) P/V valves:\nIMO MSC/Circ.677, as amended,\nEN ISO 16852:2016,\nISO 15364:2016.\n(b) Flame arresters:\nIMO MSC/Circ.677, as amended,\nEN ISO 16852:2016.\n(c) Detonation flame arresters:\nIMO MSC/Circ.677, as amended,\nEN ISO 16852:2016.\n(d) High velocity vent valves:\nIMO MSC/Circ.677, as amended,\nEN ISO 16852:2016,\nISO 15364:2016.\nFor equipment other than valves:\nB+D\nB+E\nB+F\nFor valves:\nB+F\n19.6.2018\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/4,\nSOLAS 74 Reg. II-2/16.\nIMO Res.MSC.98(73)-(FSS Code) 15.\nMED/3.13\nNon-combustible materials\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/3,\nSOLAS 74 Reg. X/3.\nIMO Res.MSC.307(88)-(2010 FTP Code), as amended.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/3,\nSOLAS 74 Reg. II-2/5,\nSOLAS 74 Reg. II-2/9,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7.\nMED/3.14, Materials other than steel for pipes penetrating “A” and “B” Class divisions – Item included in MED/3.26 and MED/3.27.\nMED/3.15a\nMaterials other than steel for pipes conveying oil or fuel oil:\nplastic pipes and fittings.\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/4,\nSOLAS 74 Reg. X/3.\nIMO Res.A.753(18), as amended,\nIMO Res.MSC.307(88)-(2010 FTP Code), as amended.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/4,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.36(63)-(1994 HSC Code) 10,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 10,\nIMO MSC/Circ.1120.\nMED/3.15b\nMaterials other than steel for pipes conveying oil or fuel oil:\nvalves.\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/4,\nSOLAS 74 Reg. X/3.\nEN ISO 10497:2010.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/4,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.36(63)-(1994 HSC Code) 10,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 10,\nIMO MSC/Circ.1120.\nMED/3.15c\nMaterials other than steel for pipes conveying oil or fuel oil:\nflexible pipe assemblies and compensators.\nRow 1 of 2\nType approval requirements\nSOLAS 74 Reg. II-2/4,\nSOLAS 74 Reg. X/3.\nFlexible pipe assemblies:\nEN ISO 15540:2001,\nEN ISO 15541:2001.\nB+D\nB+E\nB+F\n1.7.2019\n(III)\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/4,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.36(63)-(1994 HSC Code) 10,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 10,\nIMO MSC/Circ.1120.\nMED/3.15c\nMaterials other than steel for pipes conveying oil or fuel oil:\nflexible pipe assemblies and compensators.\nRow 2 of 2\nType approval requirements\nSOLAS 74 Reg. II-2/4,\nSOLAS 74 Reg. X/3.\nISO 15540:2016,\nISO 15541:2016.\nB+D\nB+E\nB+F\n19.6.2018\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/4,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.36(63)-(1994 HSC Code) 10,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 10,\nIMO MSC/Circ.1120.\nMED/3.15d\nMaterials other than steel for pipes conveying oil or fuel oil:\nmetallic pipe components with resilient and elastomeric seals.\nNote: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied.\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/4,\nSOLAS 74 Reg. X/3.\nISO 19921:2005,\nISO 19922:2005.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/4,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.36(63)-(1994 HSC Code) 10,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 10,\nIMO MSC/Circ.1120,\nIMO MSC/Circ.1527.\nMED/3.16\nFire Doors\nNote: Excludes restricted B-Class divisions/doors.\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/9.\nIMO Res.MSC.307(88)-(2010 FTP Code), as amended,\nIMO MSC.1/Circ.1319\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/9,\nIMO MSC.1/Circ.1511.\nMED/3.17\nFire door control systems components.\nNote: When the term \"system components\" is used it may be that a single component, a group of components or a whole system needs to be tested to ensure that the international requirements are fulfilled.\nNote: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied.\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/9,\nSOLAS 74 Reg. X/3.\nIMO Res.MSC.307(88)-(2010 FTP Code), as amended.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/9,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7.\nMED/3.18a\nSurface materials and floor coverings with low flame-spread characteristics:\ndecorative veneers.\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/3,\nSOLAS 74 Reg. II-2/5,\nSOLAS 74 Reg. II-2/6,\nSOLAS 74 Reg. X/3.\nIMO Res.MSC.307(88)-(2010 FTP Code), as amended.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/3,\nSOLAS 74 Reg. II-2/5,\nSOLAS 74 Reg. II-2/6,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO MSC/Circ.1120.\nMED/3.18b\nSurface materials and floor coverings with low flame-spread characteristics:\npaint systems.\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/3,\nSOLAS 74 Reg. II-2/5,\nSOLAS 74 Reg. II-2/6,\nSOLAS 74 Reg. X/3.\nIMO Res.MSC.307(88)-(2010 FTP Code), as amended.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/3,\nSOLAS 74 Reg. II-2/5,\nSOLAS 74 Reg. II-2/6,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO MSC/Circ.1120.\nMED/3.18c\nSurface materials and floor coverings with low flame-spread characteristics:\nfloor coverings.\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/3,\nSOLAS 74 Reg. II-2/5,\nSOLAS 74 Reg. II-2/6,\nSOLAS 74 Reg. X/3.\nIMO Res.MSC.307(88)-(2010 FTP Code), as amended.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/3,\nSOLAS 74 Reg. II-2/5,\nSOLAS 74 Reg. II-2/6,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO MSC/Circ.1120.\nMED/3.18d\nSurface materials and floor coverings with low flame-spread characteristics:\npipe insulation covers.\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/3,\nSOLAS 74 Reg. II-2/5,\nSOLAS 74 Reg. X/3.\nIMO Res.MSC.307(88)-(2010 FTP Code), as amended.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/3,\nSOLAS 74 Reg. II-2/5,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO MSC/Circ.1120.\nMED/3.18e\nSurface materials and floor coverings with low flame-spread characteristics:\nadhesives used in the construction of 'A', 'B' & 'C' class divisions.\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/3,\nSOLAS 74 Reg. II-2/5,\nSOLAS 74 Reg. II-2/9,\nSOLAS 74 Reg. X/3.\nIMO Res.MSC.307(88)-(2010 FTP Code), as amended.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/3,\nSOLAS 74 Reg. II-2/5,\nSOLAS 74 Reg. II-2/9,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO MSC/Circ.1120.\nMED/3.18f\nSurface materials and floor coverings with low flame-spread characteristics:\ncombustible ducts membrane.\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/3,\nSOLAS 74 Reg. II-2/5,\nSOLAS 74 Reg. II-2/9,\nSOLAS 74 Reg. X/3.\nIMO Res.MSC.307(88)-(2010 FTP Code), as amended.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/3,\nSOLAS 74 Reg. II-2/5,\nSOLAS 74 Reg. II-2/9,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO MSC/Circ.1120.\nMED/3.19\nDraperies, curtains and other suspended textile materials and films\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/3,\nSOLAS 74 Reg. II-2/9,\nSOLAS 74 Reg. X/3.\nIMO Res.MSC.307(88)-(2010 FTP Code), as amended,\nIMO MSC.1/Circ.1456, as amended.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/3,\nSOLAS 74 Reg. II-2/9,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7.\nMED/3.20\nUpholstered furniture\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/3,\nSOLAS 74 Reg. II-2/5,\nSOLAS 74 Reg. II-2/9,\nSOLAS 74 Reg. X/3.\nIMO Res.MSC.307(88)-(2010 FTP Code), as amended.\nB+D\nB+E\nB+F\n12.8.2023\n(I)\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/3,\nSOLAS 74 Reg. II-2/5,\nSOLAS 74 Reg. II-2/9,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7.\nMED/3.20a\nUpholstered furniture:\ncomplete piece of furniture (including cover material, filling material and non-flammable rack).\nRow 1 of 1\n(NEW ROW)\nType approval requirements\nSOLAS 74 Reg. II-2/3,\nSOLAS 74 Reg. II-2/5,\nSOLAS 74 Reg. II-2/9,\nSOLAS 74 Reg. X/3.\nIMO Res.MSC.307(88)-(2010 FTP Code), as amended.\nB+D\nB+E\nB+F\n12.8.2020\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/3,\nSOLAS 74 Reg. II-2/5,\nSOLAS 74 Reg. II-2/9,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7.\nMED/3.20b\nUpholstered furniture:\ncover material for any filling material.\nRow 1 of 1\n(NEW ROW)\nType approval requirements\nSOLAS 74 Reg. II-2/3,\nSOLAS 74 Reg. II-2/5,\nSOLAS 74 Reg. II-2/9,\nSOLAS 74 Reg. X/3.\nIMO Res.MSC.307(88)-(2010 FTP Code), Annex 1 Part 8 Appendix 3, as amended.\nB+D\nB+E\nB+F\n12.8.2020\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/3,\nSOLAS 74 Reg. II-2/5,\nSOLAS 74 Reg. II-2/9,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7.\nMED/3.20c\nUpholstered furniture:\ncover material for flame-retardant filling material (tested in specific combination as intended for further application).\nRow 1 of 1\n(NEW ROW)\nType approval requirements\nSOLAS 74 Reg. II-2/3,\nSOLAS 74 Reg. II-2/5,\nSOLAS 74 Reg. II-2/9,\nSOLAS 74 Reg. X/3.\nIMO Res.MSC.307(88)-(2010 FTP Code), Annex 1 Part 8 Appendix 3, as amended.\nB+D\nB+E\nB+F\n12.8.2020\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/3,\nSOLAS 74 Reg. II-2/5,\nSOLAS 74 Reg. II-2/9,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7.\nMED/3.20d\nUpholstered furniture:\nflame-retardant filling material.\nRow 1 of 1\n(NEW ROW)\nType approval requirements\nSOLAS 74 Reg. II-2/3,\nSOLAS 74 Reg. II-2/5,\nSOLAS 74 Reg. II-2/9,\nSOLAS 74 Reg. X/3.\nIMO Res.MSC.307(88)-(2010 FTP Code), Annex 1 Part 8 Appendix 3, as amended.\nB+D\nB+E\nB+F\n12.8.2020\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/3,\nSOLAS 74 Reg. II-2/5,\nSOLAS 74 Reg. II-2/9,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7.\nMED/3.21\nBedding components\nNote: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied.\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/3,\nSOLAS 74 Reg. II-2/9,\nSOLAS 74 Reg. X/3.\nIMO Res.MSC.307(88)-(2010 FTP Code), as amended.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/3,\nSOLAS 74 Reg. II-2/9,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7.\nMED/3.22\nFire dampers\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/9.\nIMO Res.MSC.307(88)-(2010 FTP Code), as amended.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/9.\nItem MED/3.23, Non-combustible duct penetrations through ‘A’ class divisions - Item deliberately left blank.\nItem MED/3.24, Electric cable transits through ‘A’ class divisions — Item deliberately left blank.\nMED/3.25\n\"A\" and \"B\" class fire proof windows and side scuttles\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/9.\nIMO Res.MSC.307(88)-(2010 FTP Code), as amended.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/9,\nIMO Res.MSC.5(48)-(IGC Code) 3,\nIMO MSC/Circ.1120.\nMED/3.26a\nPenetrations through 'A' class divisions:\nelectric cable transits.\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/9.\nIMO Res.MSC.307(88)-(2010 FTP Code), as amended,\nIMO Res.MSC.1/Circ. 1488.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/9.\nMED/3.26b\nPenetrations through 'A' class divisions:\npipe, duct, trunk, etc. penetrations.\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/9.\nIMO Res.MSC.307(88)-(2010 FTP Code), as amended,\nIMO MSC.1/Circ. 1488.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/9,\nIMO MSC.1/Circ. 1276.\nMED/3.27a\nPenetrations through 'B' class divisions:\nelectric cable transits,\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/9.\nIMO Res.MSC.307(88)-(2010 FTP Code), as amended.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/9.\nMED/3.27b\nPenetrations through 'B' class divisions:\npipe, duct, trunk, etc. penetrations.\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/9.\nIMO Res.MSC.307(88)-(2010 FTP Code), as amended.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/9.\nMED/3.28\nSprinkler systems (limited to sprinkler heads).\n(Nozzles for fixed sprinkler systems, for high speed craft (HSC) are included under this item).\nNote: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied.\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/7,\nSOLAS 74 Reg. II-2/10,\nSOLAS 74 Reg. X/3.\nISO 6182-1:2014.\nOr:\nEN 12259-1:1999 incl. A1:2001, A2:2004 and A3:2006.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/7,\nSOLAS 74 Reg. II-2/10,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.44(65),\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 8,\nIMO MSC/Circ.912,\nMSC.1/Circ.1556.\nMED/3.29\nFire-fighting hoses:\nNon-percolating lay flat firefighting hoses (range of the inside diameter from 25 mm to 52 mm).\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/10,\nSOLAS 74 Reg. X/3.\nEN 14540:2014.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/10,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7.\nMED/3.30\nPortable oxygen analysis and gas detection equipment\nRow 1 of 4\nType approval requirements\nSOLAS 74 Reg. II-2/4,\nSOLAS 74 Reg. VI/3,\nSOLAS 74 Reg. XI-1/7.\nEN 60945:2002 incl. IEC 60945 Corr. 1:2008, or IEC 60945:2002 incl. IEC 60945 Corr. 1:2008,\nIEC 60092-504:2016,\nIEC 60533:2015.\nAnd as applicable to:\n(a) Category 1: (safe area):\nEN 50104:2010,\nEN 60079-29-1:2016.\n(b) Category 2: (explosive gas atmospheres):\nEN 50104:2010,\nEN 60079-29-1:2007,\nEN 60079-0:2012 incl. A11:2013,\nEN 60079-1:2014,\nEN 60079-10-1:2015,\nEN 60079-11:2012,\nEN 60079-15:2010,\nEN 60079-26:2015.\nB+D\nB+E\nB+F\n16.3.2017\n28.2.2020\n(II)\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/4,\nSOLAS 74 Reg. VI/3,\nSOLAS 74 Reg. XI-1/7.\nIMO Res.MSC.98(73)-(FSS Code) 15,\nIMO MSC.1/Circ.1477.\nMED/3.30\nPortable oxygen analysis and gas detection equipment\nRow 2 of 4\nType approval requirements\nSOLAS 74 Reg. II-2/4,\nSOLAS 74 Reg. VI/3,\nSOLAS 74 Reg. XI-1/7.\nEN 60945:2002 incl. IEC 60945 Corr. 1:2008, or IEC 60945:2002 incl. IEC 60945 Corr. 1 :2008,\nIEC 60092-504:2016,\nIEC 60533:2015,\nAnd as applicable to:\n(a) Category 1: (safe area):\nEN 50104:2010,\nEN 60079-29-1:2016,\n(b) Category 2: (explosive gas atmospheres):\nEN 50104:2010,\nEN 60079-29-1:2016,\nEN 60079-0:2012 incl. A11:2013,\nEN 60079-1:2014,\nEN 60079-10-1:2015,\nEN 60079-11:2012,\nEN 60079-15:2010,\nEN 60079-26:2015.\nB+D\nB+E\nB+F\n19.6.2018\n6.7.2021\n(II)\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/4,\nSOLAS 74 Reg. VI/3,\nSOLAS 74 Reg. XI-1/7.\nIMO Res.MSC.98(73)-(FSS Code) 15,\nIMO MSC.1/Circ.1477.\nMED/3.30\nPortable oxygen analysis and gas detection equipment\nRow 3 of 4\nType approval requirements\nSOLAS 74 Reg. II-2/4,\nSOLAS 74 Reg. VI/3,\nSOLAS 74 Reg. XI-1/7.\nEN 60945:2002 incl. IEC 60945 Corr. 1:2008, or IEC 60945:2002 incl. IEC 60945 Corr. 1:2008,\nIEC 60092-504:2016,\nIEC 60533:2015.\nAnd as applicable to:\n(a) Category 1: (safe area):\nEN 50104:2010,\nEN 60079-29-1:2016.\n(b) Category 2: (explosive gas atmospheres):\nEN 50104:2010,\nEN 60079-29-1:2016,\nEN 60079-0:2012 incl. A11:2013,\nEN 60079-1:2014,\nEN 60079-10-1:2015,\nEN 60079-11:2012,\nEN 60079-15:2010,\nEN 60079-26:2015.\nB+D\nB+E\nB+F\n6.7.2021\n(II)\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/4,\nSOLAS 74 Reg. VI/3,\nSOLAS 74 Reg. XI-1/7.\nIMO Res.MSC.98(73)-(FSS Code) 15,\nIMO MSC.1/Circ.1477,\nIMO MSC.1/Circ.1581.\nMED/3.30\nPortable oxygen analysis and gas detection equipment\nRow 4 of 4\n(NEW ROW)\nType approval requirements\nSOLAS 74 Reg. II-2/4,\nSOLAS 74 Reg. VI/3,\nSOLAS 74 Reg. XI-1/7.\nEN 60945:2002 incl. IEC 60945 Corr. 1:2008, or IEC 60945:2002 incl. IEC 60945 Corr. 1:2008,\nIEC 60092-504:2016,\nIEC 60533:2015.\nAnd as applicable to:\n(a) Category 1: (safe area):\nEN 50104:2010,\nEN 60079-29-1:2016.\n(b) Category 2: (explosive gas atmospheres):\nEN 50104:2010,\nEN 60079-29-1:2016,\nEN IEC 60079-0:2018,\nEN 60079-1:2014,\nEN 60079-10-1:2015,\nEN 60079-11:2012,\nEN 60079-15:2010,\nEN 60079-26:2015.\nB+D\nB+E\nB+F\n12.8.2020\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/4,\nSOLAS 74 Reg. VI/3,\nSOLAS 74 Reg. XI-1/7.\nIMO Res.MSC.98(73)-(FSS Code) 15,\nIMO MSC.1/Circ.1477,\nIMO MSC.1/Circ.1581.\nItem MED/3.31, Nozzles for fixed sprinkler systems for high speed craft ((HSC), deleted as it is covered by MED/3.9 and MED/3.28.\nMED/3.32\nFire restricting materials (except furniture) for high speed craft\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. X/3.\nIMO Res.MSC.307(88)-(2010 FTP Code), as amended.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO MSC.1/Circ.1457.\nMED/3.33\nFire restricting materials for furniture for high speed craft\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. X/3.\nIMO Res.MSC.307(88)-(2010 FTP Code), as amended.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7.\nMED/3.34\nFire resisting divisions for high speed craft\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. X/3.\nIMO Res.MSC.307(88)-(2010 FTP Code), as amended.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO MSC.1/Circ.1457.\nMED/3.35\nFire doors on high speed craft\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. X/3.\nIMO Res.MSC.307(88)-(2010 FTP Code), as amended.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7.\nMED/3.36\nFire dampers on high speed craft\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. X/3.\nIMO Res.MSC.307(88)-(2010 FTP Code), as amended.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7.\nMED/3.37a\nPenetrations through fire resisting divisions on high speed craft:\nelectric cable transits.\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. X/3.\nIMO Res.MSC.307(88)-(2010 FTP Code), as amended.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7.\nMED/3.37b\nPenetrations through fire resisting divisions on high speed craft:\npipe, duct, trunk etc. penetrations.\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. X/3.\nIMO Res.MSC.307(88)-(2010 FTP Code), as amended.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7.\nMED/3.38\nPortable fire-extinguishing equipment for lifeboats and rescue boats\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. III/4,\nSOLAS 74 Reg. X/3.\nEN 3-7:2004 incl. A1:2007,\nEN 3-8:2006 incl. AC:2007,\nEN 3-9:2006 incl. AC:2007,\nEN 3-10:2009.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. III/34,\nIMO Res.A.951(23),\nIMO Res.MSC.36(63)-(1994 HSC Code) 8,\nIMO Res.MSC.48(66)-(LSA Code) I,\nIMO Res.MSC.48(66)-(LSA Code) IV,\nIMO Res.MSC.48(66)-(LSA Code) V,\nIMO Res.MSC.97(73)-(2000 HSC Code) 8.\nMED/3.39\nNozzles for equivalent water-mist fire extinguishing systems for machinery spaces and cargo pump rooms\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/10,\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.98(73)-(FSS Code) 7.\nIMO MSC/Circ.1165, as amended.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/10,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 7,\nIMO MSC.1/Circ.1313,\nIMO MSC.1/Circ.1458.\nMED/3.40\nLow-location lighting systems (components only)\nNote: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied.\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/13,\nIMO Res.MSC.98(73)-(FSS Code) 11.\nIMO Res.A.752(18),\nISO 15370:2010.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/13,\nIMO Res.A.752(18),\nIMO Res.MSC.98(73)-(FSS Code) 11.\nMED/3.41\nEmergency escape breathing devices (EEBD)\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/13.\nISO 23269-1:2008,\nand alternatively:\nFor self-contained: open-circuit compressed air breathing apparatus with full mask or mouthed piece assembly for escape:\nEN 402:2003.\nFor self-contained open-circuit compressed air breathing apparatus with a hood for escape:\nEN 1146:2005.\nFor self-contained: closed-circuit compressed air breathing apparatus:\nEN 13794:2002.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/13,\nIMO Res.MSC.98(73)-(FSS Code) 3,\nIMO MSC/Circ.849.\nMED/3.42a\nInert gas systems:\nWhole system.\nRow 1 of 1\n(NEW ITEM)\nType approval requirements\nSOLAS 74 Reg. II-2/4.\nIMO MSC/Circ.353, as amended.\nG\n12.8.2020\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/4,\nIMO Res.A.567(14),\nIMO Res.MSC.98(73)-(FSS Code) 15,\nIMO MSC/Circ.353,\nIMO MSC/Circ.485,\nIMO MSC/Circ.731,\nIMO MSC/Circ.1120.\nMED/3.42b\nInert gas system:\nSingle components.\nNote: Equipment regarded as inert gas system components under MED/3.42b are in general:\nInert gas fans/blowers\nInert gas generator\nSea water pumps for scrubber\nDeck water seal\nNon-return valves\nNote: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied.\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/4.\nIMO MSC/Circ.353, as amended.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/4,\nIMO Res.A.567(14),\nIMO Res.MSC.98(73)-(FSS Code) 15,\nIMO MSC/Circ.353,\nIMO MSC/Circ.485,\nIMO MSC/Circ.731,\nIMO MSC/Circ.1120.\nMED/3.43\nNozzles for deep fat cooking equipment fire extinguishing systems (automatic or manual type).\nNote: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied.\nRow 1 of 2\nType approval requirements\nSOLAS 74 Reg. II-2/1,\nSOLAS 74 Reg. II-2/10,\nSOLAS 74 Reg. X/3.\nISO 15371:2009.\nB+D\nB+E\nB+F\n15.11.2018\n(III)\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/1,\nSOLAS 74 Reg. II-2/10,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO MSC.1/Circ.1433.\nMED/3.43\nNozzles for deep fat cooking equipment fire extinguishing systems (automatic or manual type).\nNote: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied.\nRow 2 of 2\nType approval requirements\nSOLAS 74 Reg. II-2/1,\nSOLAS 74 Reg. II-2/10,\nSOLAS 74 Reg. X/3.\nISO 15371:2015.\nB+D\nB+E\nB+F\n16.3.2017\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/1,\nSOLAS 74 Reg. II-2/10,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO MSC.1/Circ.1433.\nMED/3.44\nFire-fighters outfit – lifeline\nRow 1 of 2\nType approval requirements\nSOLAS 74 Reg. II-2/10,\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.98(73)-(FSS Code) 3.\nIMO Res.MSC.98(73)-(FSS Code) 3, as amended,\nIMO Res.MSC.307(88)-(2010 FTP Code), as amended.\nB+D\nB+E\nB+F\n3.9.2022\n(II)\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/10,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 3.\nMED/3.44\nFire-fighters outfit – lifeline\nLifelines for breathing apparatus approved under item MED/3.7 and item MED/7.1\nRow 2 of 2\nType approval requirements\nSOLAS 74 Reg. II-2/10,\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.98(73)-(FSS Code) 3.\nIMO Res.MSC.98(73)-(FSS Code) 3, as amended,\nIMO Res.MSC.307(88)-(2010 FTP Code), as amended,\nISO 23269-2:2011.\nB+D\nB+E\nB+F\n13.9.2019\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/10,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 3.\nMED/3.45\nEquivalent fixed gas fire extinguishing systems components (extinguishing medium, head valves and nozzles) for machinery spaces and cargo pump rooms\nNote: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied.\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/10,\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.98(73)-(FSS Code) 5.\nIMO MSC/Circ.848, as amended.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/10,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 5,\nIMO MSC/Circ.848,\nIMO MSC.1/Circ.1313.\nMED/3.46\nEquivalent fixed gas fire extinguishing systems for machinery spaces (aerosol systems)\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/10,\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.98(73)-(FSS Code) 5.\nIMO MSC/Circ.1270 incl. Corr.1, as amended.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/10,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 5,\nIMO MSC/Circ.1270 incl. Corr.1,\nIMO MSC.1/Circ.1313.\nMED/3.47\nConcentrate for fixed high expansion foam fire extinguishing systems for machinery spaces and cargo pump rooms.\nNote: The fixed high expansion foam fire extinguishing system (including those systems which use inside air from their working spaces for their intended performance), for machinery spaces and cargo pump rooms must still be tested with the approved concentrate to the satisfaction of the Administration.\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/10.\nIMO MSC/Circ.670.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/10,\nIMO Res.MSC.98(73)-(FSS Code) 6.\nMED/3.48\nFixed water based local application fire-fighting systems components for use in category A machinery spaces\n(Nozzles and performance tests).\nNote: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied.\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/10,\nSOLAS 74 Reg. X/3.\nIMO MSC.1/Circ.1387.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/10,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7.\nMED/3.49a\nFixed water-based fire-fighting systems for roro spaces, vehicle spaces and special category spaces:\nPrescriptive-based systems as per IMO MSC.1/Circ.1430.\nRow 1 of 2\nType approval requirements\nSOLAS 74 Reg. II-2/19,\nSOLAS 74 Reg. II-2/20,\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.98(73)-(FSS Code) 7.\nIMO MSC.1/Circ.1430.\nB+D\nB+E\nB+F\n1.1.2024\n(III)\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/19,\nSOLAS 74 Reg. II-2/20,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 7.\nMED/3.49a\nFixed water-based fire-fighting systems for roro spaces, vehicle spaces and special category spaces:\nPrescriptive-based systems as per IMO MSC.1/Circ.1430, Revision 1.\nRow 2 of 2\n(NEW ROW)\nType approval requirements\nSOLAS 74 Reg. II-2/19,\nSOLAS 74 Reg. II-2/20,\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.98(73)-(FSS Code) 7.\nIMO MSC.1/Circ.1430, Revision 1.\nB+D\nB+E\nB+F\n12.8.2020\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/19,\nSOLAS 74 Reg. II-2/20,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 7.\nMED/3.49b\nFixed water-based firefighting systems for roro spaces, vehicle spaces and special category spaces:\nPerformance-based systems as per IMO MSC.1/Circ. 1430,\nRow 1 of 2\nType approval requirements\nSOLAS 74 Reg. II-2/19,\nSOLAS 74 Reg. II-2/20,\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.98(73)-(FSS Code) 7.\nIMO MSC.1/Circ.1430.\nB+D\nB+E\nB+F\n1.1.2021\n(III)\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/19,\nSOLAS 74 Reg. II-2/20,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 7.\nMED/3.49b\nFixed water-based firefighting systems for roro spaces, vehicle spaces and special category spaces:\nPerformance-based systems as per IMO MSC.1/Circ. 1430, Revision 1.\nRow 2 of 2\n(NEW ROW)\nType approval requirements\nSOLAS 74 Reg. II-2/19,\nSOLAS 74 Reg. II-2/20,\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.98(73)-(FSS Code) 7.\nIMO MSC.1/Circ.1430, Revision 1.\nB+D\nB+E\nB+F\n12.8.2020\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/19,\nSOLAS 74 Reg. II-2/20,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 7.\nMED/3.50, Protective clothing resistant to chemical attack, - item moved to MED/9/3.9.\nMED/3.51a\nFixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces:\nControl and indicating equipment\nNote: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied.\nRow 1 of 3\nType approval requirements\nSOLAS 74 Reg. II-2/7,\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.98(73)-(FSS Code) 9.\nElectrical installations in ships:\nEN 54-2:1997 incl. AC:1999 and A1:2006.\nAnd, as applicable, electrical and electronic installations in ships:\nIEC 60092-504:2001 incl. IEC 60092-504 Corr.1:2011,\nIEC 60533:1999.\nB+D\nB+E\nB+F\n1.6.2019\n(III)\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/7,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 9,\nIMO MSC.1/Circ.1242.\nMED/3.51a\nFixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces:\nControl and indicating equipment\nNote: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied.\nRow 2 of 3\nType approval requirements\nSOLAS 74 Reg. II-2/7,\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.98(73)-(FSS Code) 9.\nElectrical installations in ships:\nEN 54-2:1997 incl. AC:1999 and A1:2006.\nAnd, as applicable, electrical and electronic installations in ships:\nIEC 60092-504:2016,\nIEC 60533:2015.\nB+D\nB+E\nB+F\n16.3.2017\n1.1.2020\n(III)\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/7,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 9,\nIMO MSC.1/Circ.1242,\nIMO MSC.1/Circ.1487.\nMED/3.51a\nFixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces:\nControl and indicating equipment\nNote: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied.\nRow 3 of 3\nType approval requirements\nSOLAS 74 Reg. II-2/7,\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.98(73)-(FSS Code) 9.\nElectrical installations in ships:\nEN 54-2:1997 incl. AC:1999 and A1:2006.\nAnd, as applicable, electrical and electronic installations in ships:\nIEC 60092-504:2016,\nIEC 60533:2015.\nB+D\nB+E\nB+F\n19.6.2018\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/7,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 9,\nIMO Res.MSC.391(95)-(IGF Code) 11,\nIMO MSC.1/Circ.1242,\nIMO MSC.1/Circ.1487,\nIMO MSC.1/Circ.1528.\nMED/3.51b\nFixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces:\nPower supply equipment.\nNote: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied.\nRow 1 of 3\nType approval requirements\nSOLAS 74 Reg. II-2/7,\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.98(73)-(FSS Code) 9.\nEN 54-4:1997 incl. AC:1999, A1:2002 and A2:2006.\nAnd, as applicable, electrical and electronic installations in ships:\nIEC 60092-504:2001 incl. IEC 60092-504 Corr.1:2011,\nIEC 60533:1999.\nB+D\nB+E\nB+F\n1.6.2019\n(III)\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/7,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 9,\nIMO MSC.1/Circ.1242.\nMED/3.51b\nFixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces:\nPower supply equipment.\nNote: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied.\nRow 2 of 3\nType approval requirements\nSOLAS 74 Reg. II-2/7,\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.98(73)-(FSS Code) 9.\nEN 54-4:1997 incl. AC:1999, A1:2002 and A2:2006.\nAnd, as applicable, electrical and electronic installations in ships:\nIEC 60092-504:2016,\nIEC 60533:2015.\nB+D\nB+E\nB+F\n16.3.2017\n1.1.2020\n(III)\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/7,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 9,\nIMO MSC.1/Circ.1242.\nMED/3.51b\nFixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces:\nPower supply equipment.\nNote: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied.\nRow 3 of 3\nType approval requirements\nSOLAS 74 Reg. II-2/7,\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.98(73)-(FSS Code) 9.\nEN 54-4:1997 incl. AC:1999, A1:2002 and A2:2006.\nAnd, as applicable, electrical and electronic installations in ships:\nIEC 60092-504:2016,\nIEC 60533:2015.\nB+D\nB+E\nB+F\n19.6.2018\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/7,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 9,\nIMO Res.MSC.391(95)-(IGF Code) 11,\nIMO MSC.1/Circ.1242,\nIMO MSC.1/Circ.1554.\nMED/3.51c\nFixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces:\nHeat detectors - Point detectors.\nNote: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied.\nRow 1 of 4\nType approval requirements\nSOLAS 74 Reg. II-2/7,\nSOLAS 74Reg. X/3,\nIMO Res.MSC.98(73)-(FSS Code) 9.\nEN 54-5:2000 incl. A1:2002.\nAnd, as applicable, electrical and electronic installations in ships:\nIEC 60092-504:2001 incl. IEC 60092-504 Corr.1:2011,\nIEC 60533:1999.\nB+D\nB+E\nB+F\n1.6.2019\n(III)\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/7,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 9,\nIMO MSC.1/Circ.1242.\nMED/3.51c\nFixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces:\nHeat detectors - Point detectors.\nNote: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied.\nRow 2 of 4\nType approval requirements\nSOLAS 74 Reg. II-2/7,\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.98(73)-(FSS Code) 9.\nEN 54-5:2000 incl. A1:2002.\nAnd, as applicable, electrical and electronic installations in ships:\nIEC 60092-504:2016,\nIEC 60533:2015.\nB+D\nB+E\nB+F\n16.3.2017\n28.2.2020\n(III)\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/7,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 9,\nIMO MSC.1/Circ.1242.\nMED/3.51c\nFixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces:\nHeat detectors - Point detectors.\nNote: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied.\nRow 3 of 4\nType approval requirements\nSOLAS 74 Reg. II-2/7,\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.98(73)-(FSS Code) 9.\nEN 54-5:2017.\nAnd, as applicable, electrical and electronic installations in ships:\nIEC 60092-504:2016,\nIEC 60533:2015.\nB+D\nB+E\nB+F\n19.6.2018\n12.8.2023\n(III)\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/7,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 9,\nIMO MSC.1/Circ.1242.\nMED/3.51c\nFixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces:\nHeat detectors - Point detectors.\nNote: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied.\nRow 4 of 4\n(NEW ROW)\nType approval requirements\nSOLAS 74 Reg. II-2/7,\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.98(73)-(FSS Code) 9.\nEN 54-5:2017 incl. A1:2018.\nAnd, as applicable, electrical and electronic installations in ships:\nIEC 60092-504:2016,\nIEC 60533:2015.\nB+D\nB+E\nB+F\n12.8.2020\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/7,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 9,\nIMO MSC.1/Circ.1242.\nMED/3.51d\nFixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces:\nSmoke detectors: Point detectors using scattered light, transmitted light or ionization.\nNote: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied.\nRow 1 of 2\nType approval requirements\nSOLAS 74 Reg. II-2/7,\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.98(73)-(FSS Code) 9.\nEN 54-7:2000 incl. A1:2002 and A2:2006.\nAnd, as applicable, electrical and electronic installations in ships:\nIEC 60092-504:2001 incl. IEC 60092-504 Corr.1:2011,\nIEC 60533:1999.\nB+D\nB+E\nB+F\n31.8.2022\n(III)\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/7,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 9,\nIMO MSC.1/Circ.1242.\nMED/3.51d\nFixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces:\n(d) Smoke detectors: Point detectors using scattered light, transmitted light or ionization.\nNote: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied.\nRow 2 of 2\nType approval requirements\nSOLAS 74 Reg. II-2/7,\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.98(73)-(FSS Code) 9.\nEN 54-7:2018.\nAnd, as applicable, electrical and electronic installations in ships:\nIEC 60092-504:2016,\nIEC 60533:2015.\nB+D\nB+E\nB+F\n13.9.2019\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/7,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 9,\nIMO Res.MSC.391(95)-(IGF Code) 11,\nIMO MSC.1/Circ.1242.\nMED/3.51e\nFixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces:\nFlame detectors: Point detectors.\nNote: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied.\nRow 1 of 3\nType approval requirements\nSOLAS 74 Reg. II-2/7,\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.98(73)-(FSS Code) 9.\nEN 54-10:2002 incl. A1:2005.\nAnd, as applicable, electrical and electronic installations in ships:\nIEC 60092-504:2001 incl. IEC 60092-504 Corr.1:2011,\nIEC 60533:1999.\nB+D\nB+E\nB+F\n1.6.2019\n(III)\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/7,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 9,\nIMO MSC.1/Circ.1242.\nMED/3.51e\nFixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces:\nFlame detectors: Point detectors.\nNote: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied.\nRow 2 of 3\nType approval requirements\nSOLAS 74 Reg. II-2/7,\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.98(73)-(FSS Code) 9.\nEN 54-10:2002 incl. A1:2005,\nAnd, as applicable, electrical and electronic installations in ships:\nIEC 60092-504:2016,\nIEC 60533:2015.\nB+D\nB+E\nB+F\n16.3.2017\n1.1.2020\n(III)\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/7,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 9,\nIMO MSC.1/Circ.1242.\nMED/3.51e\nFixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces:\nFlame detectors: Point detectors.\nNote: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied.\nRow 3 of 3\nType approval requirements\nSOLAS 74 Reg. II-2/7,\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.98(73)-(FSS Code) 9.\nEN 54-10:2002 incl. A1:2005,\nAnd, as applicable, electrical and electronic installations in ships:\nIEC 60092-504:2016,\nIEC 60533:2015.\nB+D\nB+E\nB+F\n19.6.2018\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/7,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 9,\nIMO Res.MSC.391(95)-(IGF Code) 11,\nIMO MSC.1/Circ.1242.\nMED/3.51f\nFixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces:\nManual call points.\nNote: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied.\nRow 1 of 3\nType approval requirements\nSOLAS 74 Reg. II-2/7,\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.98(73)-(FSS Code) 9.\nEN 54-11:2001 incl. A1:2005.\nAnd, as applicable, electrical and electronic installations in ships:\nIEC 60092-504:2001 incl. IEC 60092-504 Corr.1:2011,\nIEC 60533:1999.\nB+D\nB+E\nB+F\n1.6.2019\n(III)\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/7,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 9,\nIMO MSC.1/Circ.1242.\nMED/3.51f\nFixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces:\nManual call points.\nNote: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied.\nRow 2 of 3\nType approval requirements\nSOLAS 74 Reg. II-2/7,\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.98(73)-(FSS Code) 9.\nEN 54-11:2001 incl. A1:2005.\nAnd, as applicable, electrical and electronic installations in ships:\nIEC 60092-504:2016,\nIEC 60533:2015.\nB+D\nB+E\nB+F\n16.3.2017\n1.1.2020\n(III)\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/7,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 9,\nIMO MSC.1/Circ.1242.\nMED/3.51f\nFixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces:\nManual call points.\nNote: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied.\nRow 3 of 3\nType approval requirements\nSOLAS 74 Reg. II-2/7,\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.98(73)-(FSS Code) 9.\nEN 54-11:2001 incl. A1:2005.\nAnd, as applicable, electrical and electronic installations in ships:\nIEC 60092-504:2016,\nIEC 60533:2015.\nB+D\nB+E\nB+F\n19.6.2018\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/7,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 9,\nIMO Res.MSC.391(95)-(IGF Code) 11,\nIMO MSC.1/Circ.1242.\nMED/3.51g\nFixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces:\nShort circuit isolators.\nNote: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied.\nRow 1 of 3\nType approval requirements\nSOLAS 74 Reg. II-2/7,\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.98(73)-(FSS Code) 9.\nEN 54-17:2005 incl. AC:2007.\nAnd, as applicable, electrical and electronic installations in ships:\nIEC 60092-504:2001 incl. IEC 60092-504 Corr.1:2011,\nIEC 60533:1999.\nB+D\nB+E\nB+F\n1.6.2019\n(III)\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/7,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 9,\nIMO MSC.1/Circ.1242.\nMED/3.51g\nFixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces:\nShort circuit isolators.\nNote: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied.\nRow 2 of 3\nType approval requirements\nSOLAS 74 Reg. II-2/7,\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.98(73)-(FSS Code) 9.\nEN 54-17:2005 incl. AC:2007.\nAnd, as applicable, electrical and electronic installations in ships:\nIEC 60092-504:2016,\nIEC 60533:2015.\nB+D\nB+E\nB+F\n16.3.2017\n1.1.2020\n(III)\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/7,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 9,\nIMO MSC.1/Circ.1242.\nMED/3.51g\nFixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces:\nShort circuit isolators.\nNote: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied.\nRow 3 of 3\nType approval requirements\nSOLAS 74 Reg. II-2/7,\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.98(73)-(FSS Code) 9.\nEN 54-17:2005 incl. AC:2007.\nAnd, as applicable, electrical and electronic installations in ships:\nIEC 60092-504:2016,\nIEC 60533:2015.\nB+D\nB+E\nB+F\n19.6.2018\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/7,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 9,\nIMO Res.MSC.391(95)-(IGF Code) 11,\nIMO MSC.1/Circ.1242.\nMED/3.51h\nFixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces:\nInput/output devices.\nNote: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied.\nRow 1 of 3\nType approval requirements\nSOLAS 74 Reg. II-2/7,\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.98(73)-(FSS Code) 9.\nEN 54-18:2005 including AC:2007.\nAnd, as applicable, electrical and electronic installations in ships:\nIEC 60092-504:2001 incl. IEC 60092-504 Corr.1:2011,\nIEC 60533:1999.\nB+D\nB+E\nB+F\n1.6.2019\n(III)\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/7,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 9,\nIMO MSC.1/Circ.1242.\nMED/3.51h\nFixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces:\nInput/output devices.\nNote: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied.\nRow 2 of 3\nType approval requirements\nSOLAS 74 Reg. II-2/7,\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.98(73)-(FSS Code) 9.\nEN 54-18:2005 incl. AC:2007.\nAnd, as applicable, electrical and electronic installations in ships:\nIEC 60092-504:2016,\nIEC 60533:2015.\nB+D\nB+E\nB+F\n16.3.2017\n1.1.2020\n(III)\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/7,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 9,\nIMO MSC.1/Circ.1242.\nMED/3.51h\nFixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces:\nInput/output devices.\nNote: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied.\nRow 3 of 3\nType approval requirements\nSOLAS 74 Reg. II-2/7,\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.98(73)-(FSS Code) 9.\nEN 54-18:2005 incl. AC:2007.\nAnd, as applicable, electrical and electronic installations in ships:\nIEC 60092-504:2016,\nIEC 60533:2015.\nB+D\nB+E\nB+F\n19.6.2018\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/7,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 9,\nIMO Res.MSC.391(95)-(IGF Code) 11,\nIMO MSC.1/Circ.1242.\nMED/3.51i\nFixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces:\nCables.\nNote: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied.\nRow 1 of 4\nType approval requirements\nSOLAS 74 Reg. II-2/7,\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.98(73)-(FSS Code) 9.\nEN 60332-1-2:2004,\nIEC 60092-376:2003,\nAnd, as applicable, electrical and electronic installations in ships:\nIEC 60092-504:2001 incl. IEC 60092-504 Corr.1:2011,\nIEC 60533:1999.\nB+D\nB+E\nB+F\n1.6.2019\n(III)\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/7,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 9,\nIMO MSC.1/Circ.1242.\nMED/3.51i\nFixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces:\nCables.\nNote: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied.\nRow 2 of 4\nType approval requirements\nSOLAS 74 Reg. II-2/7,\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.98(73)-(FSS Code) 9.\nEN 60332-1-2:2004,\nIEC 60092-376:2003.\nAnd, as applicable, electrical and electronic installations in ships:\nIEC 60092-504:2016,\nIEC 60533:2015.\nB+D\nB+E\nB+F\n16.3.2017\n22.5.2020\n(III)\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/7,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 9,\nIMO MSC.1/Circ.1242.\nMED/3.51i\nFixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces:\nCables.\nNote: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied.\nRow 3 of 4\nType approval requirements\nSOLAS 74 Reg. II-2/7,\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.98(73)-(FSS Code) 9.\nEN 60332-1-2:2004 incl. A1:2015,\nIEC 60092-376:2017.\nAnd, as applicable, electrical and electronic installations in ships:\nIEC 60092-504:2016,\nIEC 60533:2015,\nIEC 60332-1-2:2004 incl. A1:2015.\nAnd/or:\nFire Resistant Cables:\nIEC 60092-376:2017,\nIEC 60331-1:2009 or IEC 60331-2:2009.\nAnd, as applicable, electrical and electronic installations in ships:\nIEC 60092-504:2016,\nIEC 60533:2015,\nIEC 60332-1-2:2004 incl. A1:2015.\nB+D\nB+E\nB+F\n19.6.2018\n28.3.2021\n(III)\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/7,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 9,\nIMO Res.MSC.391(95)-(IGF Code) 11,\nIMO MSC.1/Circ.1242.\nMED/3.51i\nFixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces:\nCables.\nNote: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied.\nRow 4 of 4\nType approval requirements\nSOLAS 74 Reg. II-2/7,\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.98(73)-(FSS Code) 9.\nEN 60332-1-2:2004 incl. A1:2015 and A11:2016,\nIEC 60092-376:2017.\nAnd, as applicable, electrical and electronic installations in ships:\nIEC 60092-504:2016,\nIEC 60533:2015.\nIEC 60332-1-2:2004 incl. A1:2015.\nAnd/or:\nFire Resistant Cables:\nIEC 60092-376:2017,\nIEC 60331-1:2018 or IEC 60331-2:2018.\nAnd, as applicable, electrical and electronic installations in ships:\nIEC 60092-504:2016,\nIEC 60533:2015,\nIEC 60332-1-2:2004 incl. A1:2015.\nB+D\nB+E\nB+F\n13.9.2019\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/7,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 9,\nIMO Res.MSC.391(95)-(IGF Code) 11,\nIMO MSC.1/Circ.1242.\nMED/3.52\nNon-portable and transportable fire extinguishers\nRow 1 of 2\nType approval requirements\nSOLAS 74 Reg. II-2/10,\nSOLAS 74 Reg. X/3.\nEN 1866-1:2007,\nEN 1866-2:2014.\nOr:\nEN 1866-1:2007,\nEN 1866-3:2013.\nOr:\nISO 11601:2008.\nB+D\nB+E\nB+F\n1.7.2020\n(III)\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/4,\nSOLAS 74 Reg. II-2/10,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7.\nMED/3.52\nNon-portable and transportable fire extinguishers\nRow 2 of 2\nType approval requirements\nSOLAS 74 Reg. II-2/10,\nSOLAS 74 Reg. X/3.\nEN 1866-1:2007,\nEN 1866-2:2014.\nOr:\nEN 1866-1:2007,\nEN 1866-3:2013.\nOr:\nISO 11601:2017.\nB+D\nB+E\nB+F\n13.9.2019\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/4,\nSOLAS 74 Reg. II-2/10,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7.\nMED/3.53\nFire alarm devices – Sounders\nRow 1 of 3\nType approval requirements\nSOLAS 74 Reg. II-2/7,\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.98(73)-(FSS Code) 9.\nEN 54-3:2001 incl. A1:2002 and A2:2006,\nIEC 60092-504:2001 incl. IEC 60092-504 Corr.1:2011,\nIEC 60533:1999.\nB+D\nB+E\nB+F\n1.6.2019\n(III)\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/7,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 9.\nIMO MSC.1/Circ.1242.\nMED/3.53\nFire alarm devices – Sounders\nRow 2 of 3\nType approval requirements\nSOLAS 74 Reg. II-2/7,\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.98(73)-(FSS Code) 9.\nEN 54-3:2014,\nIEC 60092-504:2016,\nIEC 60533:2015.\nB+D\nB+E\nB+F\n16.3.2017\n12.8.2023\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/7,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 9.\nIMO MSC.1/Circ.1242,\nIMO MSC.1/Circ.1487.\nMED/3.53\nFire alarm devices – Sounders\nRow 3 of 3\n(NEW ROW)\nType approval requirements\nSOLAS 74 Reg. II-2/7,\nSOLAS 74 Reg. X/3,\nIMO Res.MSC.98(73)-(FSS Code) 9.\nEN 54-3:2014 incl. A1:2019,\nIEC 60092-504:2016,\nIEC 60533:2015.\nB+D\nB+E\nB+F\n12.8.2020\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/7,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7,\nIMO Res.MSC.98(73)-(FSS Code) 9.\nIMO MSC.1/Circ.1242,\nIMO MSC.1/Circ.1487.\nMED/3.54\nFixed oxygen analysis and gas detection equipment\nRow 1 of 4\nType approval requirements\nSOLAS 74 Reg. II-2/4,\nSOLAS 74 Reg. VI/3.\nIEC 60092-504:2001 incl. IEC 60092-504 Corr.1:2011,\nIEC 60533:1999.\nAnd, as applicable, to:\n(a) Category 4: (safe area),\nEN 50104:2010.\n(b) Category 3: (explosive gas atmospheres),\nEN 50104:2010,\nEN 60079-0:2012 incl. A11:2013,\nEN 60079-29-1:2007.\nFor combined O2/HC systems, additionally:\nIMO MSC.1/Circ.1370.\nB+D\nB+E\nB+F\n1.6.2019\n(III)\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/4,\nSOLAS 74 Reg. VI/3,\nIMO Res.MSC.98(73)-(FSS Code) 15,\nfor combined O2/HC systems additionally:\nIMO MSC.1/Circ.1370.\nMED/3.54\nFixed oxygen analysis and gas detection equipment\nRow 2 of 4\nType approval requirements\nSOLAS 74Reg. II-2/4,\nSOLAS 74 Reg. VI/3.\nIEC 60092-504:2016,\nIEC 60533:2015.\nAnd as applicable to:\n(a) Category 4: (safe area),\nEN 50104:2010.\n(b) Category 3: (explosive gas atmospheres),\nEN 50104:2010,\nEN 60079-0:2012 incl. A11:2013,\nEN 60079-29-1:2007.\nFor combined O2/HC systems, additionally:\nIMO MSC.1/Circ.1370.\nB+D\nB+E\nB+F\n16.3.2017\n3.6.2020\n(III)\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/4,\nSOLAS 74 Reg. VI/3,\nIMO Res.MSC.98(73)-(FSS Code) 15,\nfor combined O2/HC systems additionally:\nIMO MSC.1/Circ.1370.\nMED/3.54\nFixed oxygen analysis and gas detection equipment\nRow 3 of 4\nType approval requirements\nSOLAS 74 Reg. II-2/4,\nSOLAS 74 Reg. VI/3.\nIEC 60092-504:2016,\nIEC 60533:2015.\nAnd as applicable to:\n(a) Category 4: (safe area),\nEN 50104:2010.\n(b) Category 3: (explosive gas atmospheres),\nEN 50104:2010,\nEN 60079-0:2012 incl. A11:2013,\nEN 60079-29-1:2016.\nFor combined O2/HC systems, additionally:\nIMO MSC.1/Circ.1370.\nB+D\nB+E\nB+F\n19.6.2018\n12.8.2023\n(III)\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/4,\nSOLAS 74 Reg. VI/3,\nIMO Res.MSC.98(73)-(FSS Code) 15,\nfor combined O2/HC systems additionally:\nIMO MSC.1/Circ.1370.\nMED/3.54\nFixed oxygen analysis and gas detection equipment\nRow 4 of 4\n(NEW ROW)\nType approval requirements\nSOLAS 74 Reg. II-2/4,\nSOLAS 74 Reg. VI/3.\nIEC 60092-504:2016,\nIEC 60533:2015.\nAnd as applicable to:\n(a) Category 4: (safe area),\nEN 50104:2010.\n(b) Category 3: (explosive gas atmospheres),\nEN 50104:2010,\nEN IEC 60079-0:2018,\nEN 60079-29-1:2016.\nFor combined O2/HC systems, additionally:\nIMO MSC.1/Circ.1370.\nB+D\nB+E\nB+F\n12.8.2020\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/4,\nSOLAS 74 Reg. VI/3,\nIMO Res.MSC.98(73)-(FSS Code) 15,\nfor combined O2/HC systems additionally:\nIMO MSC.1/Circ.1370.\nMED/3.55\nDual purpose type nozzles\n(spray/jet type)\nRow 1 of 2\nType approval requirements\nSOLAS 74 Reg. II-2/10,\nSOLAS 74 Reg. X/3.\nHand-held branch pipes for fire service use - Combination branch pipes PN 16:\nEN 15182-1:2007 incl. A1:2009,\nEN 15182-2:2007 incl. A1:2009.\nHand-held branch pipes for fire service use - Smooth bore jet and/or one fixed spray jet angle branch pipes PN 16:\nEN 15182-1:2007 incl. A1:2009,\nEN 15182-3:2007 incl. A1:2009.\nB+D\nB+E\nB+F\n12.8.2023\n(III)\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/10,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7.\nMED/3.55\nDual purpose type nozzles\n(spray/jet type)\nRow 2 of 2\n(NEW ROW)\nType approval requirements\nSOLAS 74 Reg. II-2/10,\nSOLAS 74 Reg. X/3.\nHand-held branch pipes for fire service use - Combination branch pipes PN 16:\nEN 15182-1:2019,\nEN 15182-2:2019.\nHand-held branch pipes for fire service use - Smooth bore jet and/or one fixed spray jet angle branch pipes PN 16:\nEN 15182-1:2019,\nEN 15182-3:2019.\nB+D\nB+E\nB+F\n12.8.2020\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/10,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7.\nMED/3.56\nFixed firefighting hose systems\nHose reels with semi-rigid hose\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/10,\nSOLAS 74 Reg. X/3.\nEN 671-1:2012.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/10,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7.\nMED/3.57\nMedium Expansion Foam Fire Extinguishing Systems components - Fixed Deck Foam for Tankers\nNote: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied.\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/10.\nIMO MSC/Circ.798.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/10.8.1,\nIMO Res.MSC.98(73)-(FSS Code) 14,\nIMO MSC/Circ.1239,\nIMO MSC.1/Circ.1276.\nMED/3.58\nFixed Low Expansion Foam Fire Extinguishing Systems Components for Machinery Spaces and Tanker Deck Protection\nNote: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied.\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/10.\nIMO MSC.1/Circ.1312,\nIMO MSC.1/Circ.1312/Corr.1.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/10,\nIMO Res.MSC.98(73)-(FSS Code) 6,\nIMO Res.MSC.98(73)-(FSS Code) 14,\nIMO MSC/Circ.1239,\nIMO MSC.1/Circ.1276.\nMED/3.59\nExpansion Foam for Fixed Fire Extinguishing Systems for Chemical Tankers\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/1,\nIMO Res.MSC.4(48)-(IBC Code) 11.\nIMO MSC.1/Circ.1312,\nIMO MSC.1/Circ.1312/Corr.1.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nIMO Res.MSC.4(48)-(IBC Code) 11,\nIMO MSC/Circ.553.\nMED/3.60\nNozzles for fixed pressure water-spraying fire-extinguishing systems for cabin balconies\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/10,\nIMO Res.MSC.98(73)-(FSS Code) 7.\nIMO MSC.1/Circ.1268.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/10,\nIMO Res.MSC.98(73)-(FSS Code) 7,\nIMO MSC.1/Circ.1313.\nMED/3.61a\nInside air high expansion foam systems for the protection of machinery spaces, cargo pump rooms, vehicle and ro-ro spaces, special category spaces and cargo spaces\nNote: Inside/Outside air high expansion foam systems for the protection of machinery spaces, cargo pump rooms, vehicle and ro-ro spaces, special category spaces and cargo spaces shall be tested with the approved concentrate to the satisfaction of the Administration.\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/10.\nIMO MSC.1/Circ.1384.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/10,\nIMO Res.MSC.98(73)-(FSS Code) 6,\nIMO MSC.1/Circ.1528.\nMED/3.61b\nOutside air high expansion foam systems for the protection of machinery spaces, cargo pump rooms, vehicle and ro-ro spaces, special category spaces and cargo spaces\nNote: Inside/Outside air high expansion foam systems for the protection of machinery spaces, cargo pump rooms, vehicle and ro-ro spaces, special category spaces and cargo spaces shall be tested with the approved concentrate to the satisfaction of the Administration.\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/10.\nIMO MSC.1/Circ.1384.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/10,\nIMO Res.MSC.98(73)-(FSS Code) 6,\nIMO MSC.1/Circ.1528.\nMED/3.62\nDry chemical powder extinguishing systems\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/1.\nIMO MSC.1/Circ.1315.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/1.\nIMO Res.MSC.5(48)-(IGC Code) 11,\nIMO Res.MSC.391(95)-(IGF Code) 11.\nMED/3.63\nSample extraction smoke detection systems components\nNote: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied.\nRow 1 of 3\nType approval requirements\nSOLAS 74 Reg. II-2/7,\nSOLAS 74 Reg. II-2/19,\nSOLAS 74 Reg. II-2/20.\nIMO Res.MSC.98(73)-(FSS Code) 10.\nAnd for:\nControl and indicating equipment. Electrical installations in ships:\nEN 54-2:1997 incl. AC:1999 and A1:2006.\nPower supply equipment:\nEN 54-4:1997 incl. AC:1999, A1:2002 and A2:2006.\nAspiring smoke detectors:\nEN 54-20:2006 incl. AC:2008.\nAnd, as applicable, electrical and electronic installations in ships:\nIEC 60092-504:2001 incl. IEC 60092-504 Corr.1:2011,\nIEC 60533:1999.\nAnd, as applicable for explosive atmospheres:\nEN 60079-0:2012 incl. A11:2013.\nB+D\nB+E\nB+F\n1.6.2019\n(III)\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/7,\nSOLAS 74 Reg. II-2/19,\nSOLAS 74 Reg. II-2/20,\nIMO Res.MSC.98(73)-(FSS Code) 10.\nMED/3.63\nSample extraction smoke detection systems components\nNote: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied.\nRow 2 of 3\nType approval requirements\nSOLAS 74 Reg. II-2/7,\nSOLAS 74 Reg. II-2/19,\nSOLAS 74 Reg. II-2/20.\nIMO Res.MSC.98(73)-(FSS Code) 10.\nAnd for:\nControl and indicating equipment. Electrical installations in ships:\nEN 54-2:1997 incl. AC:1999 and A1:2006.\nPower supply equipment:\nEN 54-4:1997 incl. AC:1999, A1:2002 and A2:2006.\nAspiring smoke detectors:\nEN 54-20:2006 incl. AC:2008.\nAnd, as applicable, electrical and electronic installations in ships:\nIEC 60092-504:2016,\nIEC 60533:2015.\nAnd, as applicable for explosive atmospheres:\nEN 60079-0:2012 incl. A11:2013.\nB+D\nB+E\nB+F\n19.6.2018\n12.8.2023\n(III)\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/7,\nSOLAS 74 Reg. II-2/19,\nSOLAS 74 Reg. II-2/20,\nIMO Res.MSC.98(73)-(FSS Code) 10.\nMED/3.63\nSample extraction smoke detection systems components\nNote: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied.\nRow 3 of 3\n(NEW ROW)\nType approval requirements\nSOLAS 74 Reg. II-2/7,\nSOLAS 74 Reg. II-2/19,\nSOLAS 74 Reg. II-2/20.\nIMO Res.MSC.98(73)-(FSS Code) 10.\nAnd for:\nControl and indicating equipment. Electrical installations in ships:\nEN 54-2:1997 incl. AC:1999 and A1:2006.\nPower supply equipment:\nEN 54-4:1997 incl. AC:1999, A1:2002 and A2:2006.\nAspiring smoke detectors:\nEN 54-20:2006 incl. AC:2008.\nAnd, as applicable, electrical and electronic installations in ships:\nIEC 60092-504:2016,\nIEC 60533:2015.\nAnd, as applicable for explosive atmospheres:\nEN IEC 60079-0:2018.\nB+D\nB+E\nB+F\n12.8.2020\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/7,\nSOLAS 74 Reg. II-2/19,\nSOLAS 74 Reg. II-2/20,\nIMO Res.MSC.98(73)-(FSS Code) 10.\nMED/3.64\nC class divisions\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/3.10.\nIMO Res.MSC.307(88)-(2010 FTP Code), as amended.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/3.10,\nSOLAS 74 Reg. II-2/3.33,\nSOLAS 74 Reg. II-2/9,\nIMO MSC/Circ.1120.\nMED/3.65\nFixed hydrocarbon gas detection system\nRow 1 of 4\nType approval requirements\nSOLAS 74 Reg. II-2/4.\nIMO MSC.1/Circ.1370,\nEN 60079-0:2012 incl. A11:2013,\nEN 60079-29-1:2007,\nIEC 60092-504:2001 incl. IEC 60092-504 Corr.1:2011,\nIEC 60533:1999.\nB+D\nB+E\nB+F\n1.6.2019\n(III)\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/4,\nIMO Res.MSC.98(73)-(FSS Code) 16,\nIMO MSC.1/Circ.1370.\nMED/3.65\nFixed hydrocarbon gas detection system\nRow 2 of 4\nType approval requirements\nSOLAS 74 Reg. II-2/4.\nIMO MSC.1/Circ.1370,\nEN 60079-0:2012 incl. A11:2013,\nEN 60079-29-1:2007,\nIEC 60092-504:2016,\nIEC 60533:2015.\nB+D\nB+E\nB+F\n16.3.2017\n21.7.2019\n(III)\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/4,\nIMO Res.MSC.98(73)-(FSS Code) 16,\nIMO MSC.1/Circ.1370.\nMED/3.65\nFixed hydrocarbon gas detection system\nRow 3 of 4\nType approval requirements\nSOLAS 74 Reg. II-2/4.\nIMO MSC.1/Circ.1370,\nEN 60079-0:2012 incl. A11:2013,\nEN 60079-29-1:2016,\nIEC 60092-504:2016,\nIEC 60533:2015.\nB+D\nB+E\nB+F\n19.6.2018\n12.8.2023.\n(III)\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/4,\nIMO Res.MSC.98(73)-(FSS Code) 16,\nIMO MSC.1/Circ.1370,\nIMO MSC.1/Circ.1527.\nMED/3.65\nFixed hydrocarbon gas detection system\nRow 4 of 4\n(NEW ROW)\nType approval requirements\nSOLAS 74 Reg. II-2/4.\nIMO MSC.1/Circ.1370,\nEN IEC 60079-0:2018,\nEN 60079-29-1:2016,\nIEC 60092-504:2016,\nIEC 60533:2015.\nB+D\nB+E\nB+F\n12.8.2020\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/4,\nIMO Res.MSC.98(73)-(FSS Code) 16,\nIMO MSC.1/Circ.1370,\nIMO MSC.1/Circ.1527.\nMED/3.66\nEvacuation guidance systems used as an alternative to low-location lighting systems\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/13.\nIMO MSC.1/Circ.1168.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/13,\nIMO MSC.1/Circ.1168.\nMED/3.67\nHelicopter facility foam fire-fighting appliances\nRow 1 of 2\nType approval requirements\nSOLAS 74 Reg. II-2/18.\nEN 13565-1:2003 incl. A1:2007.\nB+D\nB+E\nB+F\n16.3.2017\n12.8.2023\n(II)\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/18,\nIMO MSC.1/Circ.1431.\nMED/3.67\nHelicopter facility foam fire-fighting appliances\nRow 2 of 2\n(NEW ROW)\nType approval requirements\nSOLAS 74 Reg. II-2/18.\nEN 13565-1:2019.\nB+D\nB+E\nB+F\n12.8.2020\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/18,\nIMO Res.MSC.98(73)-(FSS Code) 17.\nMED/3.68\nGalley Exhaust Duct Fixed Fire Extinguishing Systems components\nNote: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied.\nRow 1 of 2\nType approval requirements\nSOLAS 74 Reg. II-2/9.\nISO 15371:2009.\nB+D\nB+E\nB+F\n30.4.2018\n(III)\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/9.\nMED/3.68\nGalley Exhaust Duct Fixed Fire Extinguishing Systems components\nNote: For products used as spare parts of existing installations the relevant standards at the time of placing on board can still be applied.\nRow 2 of 2\nType approval requirements\nSOLAS 74 Reg. II-2/9.\nISO 15371:2015.\nB+D\nB+E\nB+F\n16.3.2017\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/9.\nMED/3.69\nMobile water monitor for ships constructed on or after 1 January 2016 designed to carry five or more tiers of containers on or above the weather deck\nRow 1 of 2\nType approval requirements\nSOLAS 74 Reg.II-2/10.\nIMO MSC.1/Circ.1472.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg.II-2/10,\nSOLAS 74 Reg.II-2/19,\nIMO MSC.1/Circ.1472,\nIMO MSC.1/Circ.1550.\nMED/3.69\nMobile water monitor for ships constructed on or after 1 January 2016 designed to carry five or more tiers of containers on or above the weather deck\nRow 2 of 2\nType approval requirements\nSOLAS 74 Reg.II-2/10.\nIMO MSC.1/Circ.1472.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg.II-2/10,\nSOLAS 74 Reg.II-2/19,\nIMO Res.MSC.98(73)-(FSS Code) 12,\nIMO MSC.1/Circ.1472,\nIMO MSC.1/Circ.1550.\nMED/3.70\nFire-fighting hoses\n(Semi-rigid hoses for fixed systems)\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/10,\nSOLAS 74 Reg. X/3.\nEN 694:2014.\nB+D\nB+E\nB+F\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/10,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7.\nMED/3.71\nFixed firefighting hose systems\nHose systems with lay-flat hose\nRow 1 of 1\nType approval requirements\nSOLAS 74 Reg. II-2/10,\nSOLAS 74 Reg. X/3.\nEN 671-2:2012.\nB+D\nB+E\nB+F\n16.3.2017\nCarriage and performance requirements\nSOLAS 74 Reg. II-2/10,\nIMO Res.MSC.36(63)-(1994 HSC Code) 7,\nIMO Res.MSC.97(73)-(2000 HSC Code) 7.",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eur/2020/1170/annex/division/3",
    "retrieved_at": "2026-11-01T14:42:29.903617+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}