  "heading": "CONTROL TEST",
  "text": "Carry out a determination on aliquot portions of solutions (4.1 and 4.3) such that the Ca/Mg ratio is approximately equal to that of the solutions to be analysed. To this end take (a) of standard solution (4.3) and (b-a) of standard solution (4.1). (a) and (b) are the volumes of EDTA solution in millilitres used in the two titrations performed on the solution to be analysed. This procedure is correct only if the solutions of EDTA, calcium and magnesium are exactly equivalent. If this is not the case, it is necessary to make corrections.",
  "extent": null,
  "status": null,
  "version": "current",
  "annotations": [],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/nisr/1996/513/schedule/2/part/I/chapter/22./paragraph/6",
    "retrieved_at": "2026-10-29T02:32:40.012993+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}