  "heading": "PROCEDURE",
  "text": "Preparation of blank solution\n7.1 See Method 25d (7.1).\nPreparation of calibration solutions\n7.2 See Method 25d (7.2).\nFor an optimum determination range of 0 to 5 μg/ml of copper, place 0, 0.5, 1, 2, 3, 4 and 5 ml respectively of working solution (4.4.2) in a series of 100 ml volumetric flasks. If necessary adjust the hydrochloric acid concentration as closely as possible to that of the test solution (6.2). Make up to 100 ml with 0.5 M hydrochloric acid solution (4.2) and mix thoroughly. These solutions contain 0, 0.5, 1, 2, 3, 4 and 5 μg/ml respectively of copper.\nDetermination\n7.3 See Method 25d (7.3). Prepare the spectrometer (5) for measurement at a wavelength of 324.8 nm.",
  "extent": null,
  "status": null,
  "version": "current",
  "annotations": [],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/nisr/1996/513/schedule/2/part/I/chapter/25g./paragraph/7",
    "retrieved_at": "2026-10-29T02:32:40.012993+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}