OpenLegislation

Article 104 Requirements for vessels of 21 metres in length and over but less than 24.4 metres in length

Original text. Later amendments are not shown.

(1)

In every vessel of 21 metres in length and over but less than 24.4 metres in length to which these Rules apply fire appliances shall be provided whereby at least one jet of water can reach any part of the vessel normally accessible to the crew while the vessel is being navigated and any store room and any part of any hold space when empty.

(2)

Where any oil-fired boilers or internal combustion type propelling machinery is installed in any such vessel the hull of which is constructed of wood or glass reinforced plastic and decked in way of the machinery space a means shall be provided outside the machinery space for rapidly injecting into that space a quantity of free fire smothering gas equivalent to at least 60 per cent of the gross volume of that space, or in the case of any such vessel where the machinery space is bounded by steel bulkheads, a quantity of fire smothering gas equivalent to 40 per cent of the gross volume of the space.

(3)

In every such vessel at least one fire pump operated by power shall be provided which shall be capable of delivering at least one jet of water from any fire hydrant, hose and nozzle provided in the vessel and which shall comply with the requirements of Rule 107 of these Rules. This pump may be driven by the main engine.

(4)

In every such vessel where oil-fired boilers or internal combustion type propelling machinery are installed, if the pump required by paragraph (3) above and its source of power and sea connection are not situated outside spaces containing such boilers or machinery, there shall be provided in a position outside such spaces an additional fire pump and its source of power and sea connection. If this pump is operated by power it shall comply with the requirements of paragraph (3) above and if it is manually operated it shall be provided with a hose and a 9.5 millimetre diameter nozzle through which it shall be capable of producing a jet of water having a throw of not less than 6 metres which can be directed on to any part of the vessel.

(5)

In every such vessel a fire main, water service pipes and hydrants shall be provided which shall comply with the requirements of Rule 108 of these Rules and at least two fire hoses.

(6)

A spray nozzle suitable for use with the fire hoses required by paragraph (5) above shall be provided in every such vessel fitted with oil-fired boilers or internal combustion type propelling machinery.

(7)

In every such vessel at least three portable fire extinguishers so situated as to be readily available for use in the accommodation and service spaces shall be provided. The extinguishing medium provided in any extinguisher placed in an area of fire risk shall be suitable for the type of fire risk involved.

(8)

At least two portable fire extinguishers suitable for extinguishing oil fires shall be provided in every such vessel which is fitted with oil-fired boilers or internal combustion type propelling machinery in addition to the requirements of paragraph (7) above.