# The Fishing Vessels (Safety Provisions) Rules 1975, Article 105: Requirements for vessels of 9 metres in length and over but less than 21 metres in length


(1) In every vessel of 9 metres in length and over but less than 21 metres in length to which these Rules apply fire appliances shall be provided whereby at least one jet of water can reach any part of the vessel normally accessible to the crew while the vessel is being navigated and any store room and any part of any hold space when empty.
(2) Where any oil-fired boiler or internal combustion type propelling machinery is installed in any such vessel the hull of which is constructed of wood or glass reinforced plastic and decked in way of the machinery space a means shall be provided outside the machinery space for rapidly injecting into that space a quantity of fire smothering gas equivalent to at least 60 per cent of the gross volume of that space, or in any case where the machinery space is bounded by steel bulkheads, a quantity of free fire smothering gas equivalent to 40 per cent of the gross volume of the space, provided that there may be substituted a water spraying system supplied from a hand pump and a permanent sea connection situated outside the machinery space which may be the hand pump and the permanent connection referred to in paragraph (3) below. Such pump shall be connected by fixed piping to a sufficient number of water spraying nozzles suitably sited in the machinery space and capable of extinguishing oil fires.
(3) In every such vessel a hand pump with a permanent sea connection and a hose with a 9.5 millimetre diameter nozzle capable of producing a jet of water having a throw of not less than 6 metres which can be directed on to any part of the vessel shall be provided in a position outside the machinery spaces and in addition a spray nozzle suitable for use with the hose.
(4) In every such vessel at least two portable fire extinguishers shall be provided. The extinguishing medium provided shall be suitable for the type of fire risk involved.
(5) In every such vessel at least two portable fire extinguishers suitable for extinguishing oil fires shall be provided in vessels fitted with oil-fired boilers or internal combustion type propelling machinery in addition to the requirements of paragraph (4) above.

---
Source: https://www.legislation.gov.uk/uksi/1975/330/article/105 (the official version)
Page: https://openlegislation.uk/fishing-vessels-safety-provisions-rules-1975/article-105
Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives.

