# The Fishing Vessels (Safety Provisions) Rules 1975, Article 111: Requirements for fire alarm and fire detection systems


(1) In every vessel to which these Rules apply, where an automatic fire alarm and fire detection system is installed it shall comply with the requirements specified in this Rule and shall be installed and so arranged as to protect all accommodation spaces and service spaces in the vessel provided that the foregoing provisions of this Rule shall not apply:—
(a) to the extent that there is no substantial fire risk in the accommodation spaces and service spaces; or
(b) in respect of any store room which is provided with adequate arrangements for the detection of fire or for the smothering of fire by gas or other suitable means.
(2) In every such vessel every fire detection system shall be fit for its intended service and be capable of automatically indicating the presence of fire and its location. The indicators shall be positioned in the wheelhouse or they may be distributed among several stations provided such distribution is at least as effective as if the indicators were positioned in the wheelhouse.
(3) The indicating system of any fire detecting system in every such vessel shall operate both audible and visible alarms at the stations referred to in paragraph (2) above.
(4) In every such vessel of 24.4 metres in length and over electrical equipment used in the operation of any fire detection system fitted in compliance with these Rules shall be supplied from two sources of electric power one of which shall be the emergency source of power required by Rule 41 of these Rules.

---
Source: https://www.legislation.gov.uk/uksi/1975/330/article/111 (the official version)
Page: https://openlegislation.uk/fishing-vessels-safety-provisions-rules-1975/article-111
Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives.