# The Fishing Vessels (Safety Provisions) Rules 1975, Article 117: Fire control plans


(1) In every vessel of 45 metres in length and over to which these Rules apply there shall be permanently exhibited for the guidance of the crew general arrangement plans showing clearly for each deck the position of the control stations, the sections of the vessel which are enclosed by fire resisting bulkheads, the sections of the vessel which are enclosed by fire retarding bulkheads, together with particulars of the fire detection systems, the fixed and portable fire extinguishing appliances and firemen's outfits, the means of access to the various compartments and decks in the vessel, the ventilating system including particulars of the master fan controls, the position of dampers and identification numbers of the ventilating fans serving each section of the vessel, the location of the international shore connection and the position of all means of control referred to in Rule 116 of these Rules.
(2) In every such vessel the general arrangement plans required by this Rule shall be kept up-to-date, any alterations being recorded thereon without delay.

---