  "url": "https://openlegislation.uk/fishing-vessels-safety-provisions-rules-1975/schedule-20/paragraph-6",
  "json_url": "https://openlegislation.uk/fishing-vessels-safety-provisions-rules-1975/schedule-20/paragraph-6.json",
  "legislation": "uksi/1975/330",
  "legislation_title": "The Fishing Vessels (Safety Provisions) Rules 1975",
  "legislation_url": "https://openlegislation.uk/fishing-vessels-safety-provisions-rules-1975",
  "path": "schedule/20/paragraph/6",
  "kind": "paragraph",
  "number": "6",
  "heading": null,
  "text": "A reinforced discharge hose shall be provided, together with a nozzle, the area of which shall be such that, when the extinguisher is operated, the foam is projected a distance of 14 metres for a period of not less than 100 seconds in the case of an extinguisher of 136 litres capacity or over, and a distance of 11 metres for a period of not less than 90 seconds in the case of an extinguisher of under 136 litres.",
  "extent": null,
  "status": null,
  "version": "current",
  "annotations": [],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/uksi/1975/330/schedule/20/paragraph/6",
    "retrieved_at": "2026-10-29T21:14:59.180322+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}