# Gas Safety (Installation and Use) Regulations (Northern Ireland) 1997, Regulation 30: Room-sealed appliances

Extent: N.I.
Status: prospective

(1) A person shall not install a gas appliance in a room used or intended to be used as a bathroom or a shower room unless it is a room-sealed appliance.
(2) A person shall not install a gas fire, other gas space heater or a gas water heater of more than 14 kilowatt heat input in a room used or intended to be used as sleeping accommodation unless the appliance is a room-sealed appliance.
(3) A person shall not install a gas fire, other gas space heater or a gas water heater of 14 kilowatt heat input or less in a room used or intended to be used as sleeping accommodation unless—
(a) it is a room-sealed appliance; or
(b) it incorporates a safety control designed to shut down the appliance before there is a build up of a dangerous quantity of the products of combustion in the room concerned.

---