# The Health and Safety (Foundries etc.) (Metrication) Regulations 1981, Schedule THE: AMENDMENTS TO REGULATIONS


1
2
3
4
Regulation to be amended
Subject matter of measurement
Present measurement
Measurement to be substituted
The Blasting (Castings and other Articles) Special Regulations 1949
Regulation 12(3)
Minimum rate at which clean air to be supplied to helmet
six cubic feet per minute
170 litres per minute
Regulation 17(2)
Minimum distance from blasting enclosure
twenty feet
6 metres
The Iron and Steel Foundries Regulations 1953
Regulation 5
(a) Distance from spout of cupola or furnace within which work not to be carried out
twelve feet
4 metres
(b) Distance from ladle within which work not to be carried out
eight feet
2.4 metres
Regulation 6(1)(c)
Minimum width of certain gangways
three feet
920 millimetres
Regulation 6(1)(d)(i)
Minimum amount gangways shall be wider than overall width of ladle
two feet
600 millimetres
Regulation 6(1)(d)(ii)
Minimum width of certain gangways
three feet
920 millimetres
Regulation 6(1)(d)(iii)
Minimum width of certain gangways
four feet
1.2 metres
Regulation 6(1)(d)(iv)
Minimum width of certain gangways
six feet
1.8 metres
Regulation 6(2)(a)(iii)
Minimum width of pouring aisles
eighteen inches
460 millimetres
Regulation 6(2)(b)(ii)
Minimum width of pouring aisles
eighteen inches
460 millimetres
Non-Ferrous Metals (Melting and Founding) Regulations 1962
Regulation 2(2)
Definition of “degrees”
degrees Fahrenheit
degrees Celsius
Regulation 10(1)(a)
(a) Minimum width of pouring aisles
eighteen inches
460 millimetres
(b) Minimum height of moulds above floor
twenty inches
510 millimetres
(c) Minimum width of pouring aisles when moulds alongside are more than minimum height above the floor
twenty-four inches
600 millimetres
Regulation 10(1)(b)
Minimum width of pouring aisles
thirty inches
760 millimetres
Regulation 10(2)(a)
Minimum width of certain gangways
three feet
920 millimetres
Regulation 10(2)(c)(i)
Minimum amount gangways shall be wider than overall width of ladle
two feet
600 millimetres
Regulation 10(2)(c)(ii)
Minimum width of certain gangways
four feet
1.2 metres
Regulation 10(2)(c)(iii)
Minimum width of certain gangways
six feet
1.8 metres
Regulation 14
(a) Minimum room temperature
fifty degrees
10 degrees
(b) Maximum outside temperature at which proviso applies
thirty degrees
−1 degree
(c) Minimum amount by which room temperature should exceed outside temperature
twenty degrees
11 degrees
Regulation 15(2)(c)
Maximum interval at which taps or jets to be fitted to trough
two feet
600 millimetres
Regulation 15(3)(a)
(a) Definition of “unit” in terms of length of trough
two feet
600 millimetres
(b) Definition of “unit” in terms of section of circumference of trough
two feet
600 millimetres
Regulation 15(3)(c)
Minimum internal measurement of basin or other receptacle
four feet
1.2 metres
Regulation 17
Minimum height to which walls are to be cleaned
fourteen feet
4.2 metres

---
Source: https://www.legislation.gov.uk/uksi/1981/1332/schedule (the official version)
Page: https://openlegislation.uk/health-and-safety-foundries-etc-metrication-regulations-1981/schedule
Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives.