# The Health and Safety (Miscellaneous Provisions) (Metrication etc.) Regulations 1992, Part II: AMENDEMENTS TO REGULATION AND ORDERS


Flax and Tow Spinning and Weaving Regulations 1906
Definitions
Degrees
Fahrenheit
Celsius
Regulation 3
Minimum temperature of room where hand-hackling, roughing or machine-hackling carried on
50 degrees
10 degrees
Minimum temperature of room where sorting, carding or preparing is carried on
55 degrees
13 degrees
Temperature of direct draught below which no person should be exposed
50 degrees
10 degrees
Regulation 5
Minimum difference between wet and dry bulb thermometer readings
2 degrees
1 degree
Regulation 6
Temperature of water absorbing oxygen from potassium permanganate solution
60 degrees
16 degrees
Maximum amount of oxygen absorbed by water used for humidification
0.5 grain of oxygen per gallon
7 milligrams of oxygen per litre
Regulation 8
Temperature in rooms into which steam is introduced
70 degrees
21 degrees
Regulation 9
Pitch of wet-spinning frames required to have splash guards
2¾ inches
70 millimetres
Regulation 11
Minimum difference between wet and dry bulb thermometer readings
4 degrees
2 degrees
Paints and Colours Regulations 1907
Application, paragraph (2)
Minimum weight of parcels or kegs above which the prohibition on women’s employment applies
14 lbs
6 kilograms
Hemp Spinning and Weaving Regulation 1907
Definitions
Degrees
Fahrenheit
Celsius
Regulation 4
Minimum temperature of room where machine-hackling is carried on
50 degrees
10 degrees
Minimum temperature of room where carding or preparing is carried on
55 degrees
13 degrees
Regulation 5
Temperature of direct draught below which no person should be exposed
50 degrees
10 degrees
Herring Curing (Norfolk and Suffolk) Welfare Order 1920
Article 1
Maximum walking distance from factory to workshop in certain areas (exemption from requirement to provide a messroom)
400 yards
400 metres
Article 4
Maximum distance of cloakroom and washing facilities from factory or workshop
250 yards
250 metres
The Celluloid (Manufacture Etc.) Regulations 1921
Regulation 1(i)
Maximum quantity of celluloid not kept in fire-resisting chamber
one hundredweight
50 kilograms
Maximum quantity of celluloid indicated on notice on storeroom door
one hundredweight
50 kilograms
The Manufacture of Cinematograph Film Regulations 1928
Definitions
“Fire-resisting material”
(a) Minimum thickness of brickwork;
four and one-half inches
100 millimetres
(b) Minimum thickness of concrete;
three inches
75 millimetres
(c) Minimum thickness of breeze slabbing;
three inches
75 millimetres
(d) Minimum thickness of oak or teak;
two inches
50 millimetres
(e) Minimum thickness of glass.
one quarter of an inch
6 millimetres
“Storeroom”
Maximum quantity of film allowed
eighty pounds
37 kilograms
Regulation 2
Quantity of cinematograph film allowed in any room
eighty pounds
37 kilograms
Regulation 8(a)
Minimum and maximum areas of gas relief space in storerooms
70 square inches
90 square inches
200 square centimetres
260 square centimetres
For each weight of film
500 pounds
100 kilograms
Regulation 9(b)(ii)
Maximum quantity of cinematograph film in storeroom
one ton
1 tonne
Horizontal Milling Machines Regulations 1928
Exemptions
Regulation 3 does not apply to milling cutters used on:
Spindles of diameters above
2½ inches
65 millimetres
arbors of diameters above
2 inches
50 millimetres
Cotton Cloth Factories Regulations 1929
Definitions
Degrees
Fahrenheit
Celsius
Regulation 1(a)
Wet bulb hygrometer reading above which artificial humidification is prohibited
72½ degrees
22.5 degrees
Regulation 1
Average wet bulb reading above which work is to cease
80 degrees
27 degrees
Average wet bulb reading at which work may resume
80 degrees
27 degrees
Regulation 2
Temperature of water absorbing oxygen from potassium permanganate solution
60 degrees
16 degrees
Maximum amount of oxygen absorbed by water used for humidification
0.5 grain of oxygen per gallon
7 milligrams of oxygen per litre
Regulation 5
Minimum temperature in weaving shed during first half hour of working day
50 degrees
10 degrees
Minimum temperature in weaving shed for the working day after first half hour
55 degrees
13 degrees
Temperature of draught below which no person should be exposed
50 degrees
10 degrees
Regulation 6(a)
Maximum diameter of steam pipes
two inches
50 millimetres bore
Maximum diameter of steam pipes installed after 1 April 1912
one inch
25 millimetres bore
Regulation 6(d)
Minimum thickness of insulator between hangers and steam pipes
Half an inch
13 millimetres
Regulation 6(e)
Maximum projection of uncovered jet from steam pipe beyond outer surface of covering
4½ inches
115 millimetres
Regulation 6(f)
Maximum steam pressure
70 lbs per square inch
4.8 bar
Regulation 7(a)
Minimum average height of shed
14½ feet
4.4 metres
Minimum height of valley-gutters from floor
12 feet
3.6 metres
Regulation 7(d)
Minimum width of alley-way separating boiler house and engine room from shed
6 feet
2 metres
Regulation 7(e)
Minimum horizontal distance between any boiler flue and wall of shed
6 feet
2 metres
Regulation 9
Minimum distance of roof ventilator intakes above ridges
three feet
920 millimetres
Average of wet bulb readings between 11 am and 12 noon and between 4 and 5 pm above which all available means of natural ventilation should be kept in full operation
72½ degrees
22.5 degrees
Regulation 10
Minimum horizontal distance between clothes pegs in cloak room
eighteen inches
460 millimetres
Minimum distance of clothes pegs from wall or pillar
Half an inch
13 millimetres
Oil Cake Welfare Order 1929
Article 6
Temperature of bath water
100 degrees Farenheit
38 degrees Celsius
Petroleum-Spirit (Motor Vehicles etc) Regulations 1929
Regulation 5(d)(ii)
Maximum capacity of each of two storage vessels
two gallons
10 litres
Regulation 6
Maximum quantity of petroleum-spirit in a storage place
sixty gallons
275 litres
Regulation 6(b)
Maximum distance between two storage places in the occupation of the same occupier deemed one storage place
Twenty feet
6 metres
Regulation 7(1)
Maximum capacity of storage vessel
two gallons
10 litres
Regulation 7(1)(a)
Minimum distance of storage place from any building, highway or public footpath
Twenty feet
6 metres
Regulation 7(2)
Capacity of storage vessel above which occupier should notify the local authority
two gallons
10 litres
Regulation 8(1)
Minimum distance of storage place from any building, stack of timber or other inflammable substance before notification is required
Twenty feet
6 metres
Regulation 8(1)(b)
Maximum capacity of each of two storage vessels on motor vehicle, motorboat, hovercraft or aircraft
two gallons
10 litres
Regulation 11(b)
Maximum quantity of petroleum-spirit for use in cleaning or as a solvent for repair purposes
one gill
150 millilitres
Regulation 13(b)
Increase in the maximum quantity of petroleum-spirit in a storage place in connection with making or repair of roads
sixty gallons
thirty gallons
275 litres
140 litres
Regulation 13(d)
Maximum capacity of any storage vessel in connection with making or repair of roads
two gallons
10 litres
Regulation 13(g)
Minimum distance of iron locker for containing storage vessels from any means of exit from a theatre, music hall, cinema or other place of public entertainment or from a hospital
fifty feet
15 metres
Minimum distance of iron locker from any means of exit from any other place where persons assemble for any purpose, or from a dwelling house
fifteen feet
5 metres
Regulation 13(h)
Minimum distance from iron locker of any fire or artificial light liable to ignite flammable vapour
Twenty feet
6 metres
The Petroleum (Carbide of Calcium) Order 1929
Article 2(i)
Maximum quantity of carbide of calcium which may be kept without a licence so long as it is kept in separate hermetically closed metal vessels
5 lbs
2.5 kilograms
Maximum quantity to be kept in each hermetically closed metal vessel
1 lb
500 grams
Article 2(ii)
Maximum quantity of carbide of calcium which may be kept without a licence so long as it is kept in accordance with the conditions in articles 2(ii)(a)-(e)
28 lbs
13 kilograms
Petroleum (Mixtures) Order 1929
Article 2
Maximum quantity of non-liquid mixtures of petroleum which may be kept without a licence so long as it is enclosed in hermetically sealed packages or vessels
30 lbs
15 kilograms
Maximum quantity to be kept in each hermetically sealed package or vessel
1 lb
500 grams
Article 4
Substitution of units of mass for units of volume for solid mixtures of petroleum
gallons
ten pounds
one gallon
one and a quarter pounds
one pint
litres
5 kilograms
5 litres
570 grams
570 millilitres
Cinematograph Film Stripping Regulations 1939
Definitions
“Fire-resisting material”
(a) Minimum thickness of brickwork;
four and one-half inches
100 millimetres
(b) Minimum thickness of concrete;
three inches
75 millimetres
(c) Minimum thickness of breeze slabbing;
three inches
75 millimetres
(d) Minimum thickness of oak or teak;
two inches
50 millimetres
(e) Minimum thickness of glass
one quarter of an inch
6 millimetres
Part I
Regulation 2
Maximum quantity of cinematograph film in room other than storeroom
100 pounds
45 kilograms
Regulation 9(d)
Maximum temperature in drying enclosure
100° Fahrenheit
38 degrees Celsius
Regulation 10(a)(i)
Minimum distance between storeroom and buildings where persons are regularly present
20 feet
6 metres
Regulation 10(a)(vi)
Minimum height of wall above the roof between adjacent storerooms
3 feet
920 millimetres
Regulation 10(b)(ii)
Maximum quantity of cinematograph film in storeroom
one ton
1 tonne
Regulation 11(a)
Ratio of gas relief space to space in storeroom
one square foot
fifty cubic feet
1 square metre
15 cubic metres
The Magnesium (Grinding of Castings and Other Articles) Special Regulations 1946
Regulation 7(d)
Maximum horizontal distance that dust-laden air should travel before being drenched with water
ten feet
3 metres
Regulation 11(1)
Minimum distance from buildings where dust sludge or scale from scrubber can be disposed of by:
Burning in the open air
100 feet
30 metres
burning in an open incinerator
100 feet
30 metres
Regulation 13(a)
Distance from certain processes below which smoking, open lights and fires are prohibited
twenty feet
6 metres
Clay Works (Welfare) Special Regulations 1948
Regulation 4(1)(c)
Maximum intervals between warm water supply points above troughs
two feet
600 millimetres
Regulation 4(2)(a)
Meaning of “unit” (of washing facilities):
length of trough
two feet
600 millimetres
circumference of circular or oval trough
two feet
600 millimetres
Regulation 4(2)(d)
Minimum internal length or width of trough
four feet
1.2 metres
The Jute (Safety, Health and Welfare) Regulations 1948
Regulation 14(a)
Minimum temperature deemed reasonable where the only work done is opening of bales, or the batching or softening of jute
55 degrees
13 degrees Celsius
Regulation 14(b)
Minimum temperature deemed reasonable where other work is done
60 degrees
16 degrees Celsius
Regulation 16(1)(a)
Minimum width of alleyway separating engine-room, boiler-house and boiler flue from workroom
six feet
2 metres
Regulation 16(1)(b)
Minimum ventilated space separating workroom from boiler flue passing underneath
six feet
2 metres
Regulation 17(5)
Temperature of water absorbing oxygen from permanganate of potash solution
sixty degrees
16 degrees Celsius
Maximum amount of oxygen absorbed by water used for humidification
Half a grain of oxygen per gallon
7 milligrams of oxygen per litre
Regulation 18(1)(i)
Wet bulb thermometer reading above which artificial humidification is prohibited
seventy-two and a half degrees
22.5 degrees Celsius
Regulation 18(1)(ii)
Minimum difference between the wet bulb and dry bulb thermometer readings during artificial humidification
four degrees
2 degrees Celsius
Regulation 18(2)
Wet bulb reading at which all means of ventilation and reducing temperature are to be put into operation
seventy-five degrees
24 degrees Celsius
Wet bulb reading to be reached by the above means
seventy-two and a half degrees
22.5 degrees Celsius
Regulation 22(1)(c)
Maximum interval between water supply points above troughs
two feet
600 millimetres
Regulation 22(1)(d)
Meaning of “unit” (of washing facilities):
length of trough
two feet
600 millimetres
circumference of circular or oval trough
two feet
600 millimetres
Schedule 1
Requirement (a) for opening machines
Minimum length of feed table or feed band at opening machines
4 feet 6 inches
1.35 metres
Height from the floor to which guards for table or band should extend
4 feet 6 inches
1.35 metres
Distance which guard should extend from the vertical plane in which the nip of the roller lies
2 feet
600 millimetres
Requirement (c) for softening machines
Minimum length of feed table in front of first pair of rollers on softening machines
6 feet
1.80 metres
Height from floor to which guards for feed table should extend
4 feet 6 inches
1.35 metres
Distance which guard should extend from vertical plane in which axis of the roller lies
3 feet 6 inches
1.05 metres
Requirement (a) for carding and teasing machines
Maximum distance from floor to underside of guard enclosing side gearing of carding and teasing machines
8 inches
200 millimetres
Requirement (c) for carding and teasing machines
Maximum space between bars or rods of guard on doffing roller
1½ inches
38 millimetres
Minimum distance from doffer pin points to underside of rods or bars
4 inches
100 millimetres
Maximum space between drawing pressing roller and first rod
2 inches
50 millimetres
Minimum distance between outermost bars or rods measured over periphery of guard
12 inches
300 millimetres
Requirement (e) for carding and teasing machines
Maximum distance between lowest cross-member of underframe and floor
8 inches
200 millimetres
Maximum space between bars or rods covering openings above lowest cross-member
6 inches
150 millimetres
Requirement for cop winding machines
Maximum width of slots in fencing for pedal levers in cop winding machines of “cop above cone” type
1 inch
25 millimetres
Requirement (c) for dressing machines, cylinder and box or store type
Minimum space between any yarn guide roller and its adjacent steam cylinder on cylinder type dressing machines
3 inches
75 millimetres
Requirement for looms
Maximum clearance between guard and shuttle when shuttle is placed on fell of cloth with loom crank shaft on top centre
½ inch
13 millimetres
The Agriculture (Lifting of Heavy Weights) Regulations 1959
Regulation 3
Maximum weight of a sack or bag permitted to be lifted or carried by a worker unaided
180 lb
80 kilograms
Factories (Cleanliness of Walls and Ceilings) Order 1960
The Schedule
Paragraph 9(d)
Height above which parts of rooms, passages and staircases are exempt
twenty feet
6 metres
Gas safety Regulations 1972
Regulation 5(a)
Internal diameter of service pipe
2 inches
50 millimetres
Regulation 10(d)
Minimum fall of pipe