Schedule Approved plans to be substituted into Part 3 (Approved plans) of Schedule 1 (Authorised project) to the Order
“
HPC Permanent Development Site Site Plans Drawing number Rev Drawing title Scale Paper size HINK-A1-SL-00-GA-002 02 HPC Site Parameter Plan 1:1000 A0 HINK-A1-SL-00-GA-010 02 Site Layout Plan (Operational) 1:2500 A1 Nuclear Island (Unit 1) Unit 1: Reactor Building / Fuel Building / Fuel Building Hall / Boron Storage / Safeguard Buildings / Nuclear Auxiliary Building / Access Tower / Service Access Building 2 Drawing number Rev Drawing title Scale Paper size HINK-A2-HR-01-GP-090 02 Roof Plan 1:200 A0 HINK-A2-HR-01-GE-001 02 South and West Elevations 1:200 A0 HINK-A2-HR-01-GE-002 02 North and East Elevations 1:200 A0 HINK-A2-HR-01-DT-001 01 Part Elevation Detail 1:50 A0 Radioactive Waste Storage / Radioactive Waste Process Building Drawing number Rev Drawing title Scale Paper size HINK-A2-HQ-00-GA-001 01 Roof Plan and Elevations 1:200 A0 HINK-A2-HQ-00-DT-001 01 Part Elevation Detail 1:50 A0 Hot Laundry / Hot workshop / Hot warehouse / Facilities for Decontamination / Effluent Tanks / Refuelling Water Storage Tank / Battery Load Bank Drawing number Rev Drawing title Scale Paper size HINK-A2-HV-00-GP-020 02 Roof Plan 1:200 A1 HINK-A2-HV-00-GE-001 02 Elevations 1:200 A1 HINK-A2-HV-00-DT-001 02 Part Elevation Detail 1:50 A1 Emergency Diesel Generator – A / Cooling Water Discharge Weir (Building) Drawing number Rev Drawing title Scale Paper size HINK-A2-HD-01-GP-040 02 Roof Plan 1:200 A1 HINK-A2-HD-01-GE-001 02 Elevations 1:200 A1 HINK-A2-HD-01-DT-001 02 Part Elevation Detail 1:50 A1 Emergency Diesel Generator – B / Cooling Water Discharge Weir (Building) / Battery Load Bank Drawing number Rev Drawing title Scale Paper size HINK-A2-HD-02-GP-040 02 Roof Plan 1:200 A1 HINK-A2-HD-02-GE-001 02 Elevations 1:200 A1 HINK-A2-HD-02-DT-001 02 Part Elevation Detail 1:50 A1 Service Access Building 1 Drawing number Rev Drawing title Scale Paper size HINK-A2-HGC-00-GA-001 01 Roof Plan & Elevations 1:100 A1 Nuclear Island (Unit 2) Unit 2: Reactor Building / Fuel Building / Fuel Building Hall / Boron Storage / Safeguard Buildings / Nuclear Auxiliary Building / Access Tower / Service Access Building 3 Drawing number Rev Drawing title Scale Paper size HINK-A2-HR-02-GP-090 02 Roof Plan 1:200 A0 HINK-A2-HR-02-GE-001 01 South and West Elevations 1:200 A0 HINK-A2-HR-02-GE-002 02 North and East Elevations 1:200 A0 HINK-A2-HR-02-DT-001 01 Part Elevation Detail 1:50 A0 Radioactive Waste Treatment Building / Battery Load Bank Drawing number Rev Drawing title Scale Paper size HINK-A2-HQC-00-GP-040 02 Roof Plan 1:100 A1 HINK-A2-HQC-00-GE-001 02 Elevations 1:100 A1 HINK-A2-HQC-00-DT-001 02 Part Elevation Detail 1:50 A1 Emergency Diesel Generator – C / Cooling Water Discharge Weir (Building) Drawing number Rev Drawing title Scale Paper size HINK-A2-HD-03-GP-040 02 Roof Plan 1:200 A1 HINK-A2-HD-03-GE-001 02 Elevations 1:200 A1 HINK-A2-HD-03-DT-001 02 Part Elevation Detail 1:50 A1 Emergency Diesel Generator – D / Cooling Water Discharge Weir (Building) Drawing number Rev Drawing title Scale Paper size HINK-A2-HD-04-GP-040 02 Roof Plan 1:200 A1 HINK-A2-HD-04-GE-001 02 Elevations 1:200 A1 HINK-A2-HD-04-DT-001 02 Part Elevation Detail 1:50 A1 Service Access Building 4 Drawing number Rev Drawing title Scale Paper size HINK-A2-HGB-00-GA-001 01 Roof Plan & Elevations 1:100 A1 Conventional Island (Unit 1) Unit 1: Turbine Hall Drawing number Rev Drawing title Scale Paper size HINK-A1-HM-01-GA-006 02 Roof Plan, North and South Elevations 1:200 A0 HINK-A1-HM-01-GE-001 02 West and East Elevations 1:200 A0 HINK-A1-HM-01-DT-001 01 Part Elevation Detail 1:50 A0 Unit 1: Sky Bridges Drawing number Rev Drawing title Scale Paper size HINK-A1-BR-01-GP-010 01 Roof Plan 1:100 A1 HINK-A1-BR-01-GE-001 01 North and South Elevations 1:100 A1 HINK-A1-BR-01-GE-002 01 East and West Elevations 1:100 A1 HINK-A1-BR-01-DT-001 01 Part Elevation Detail 1:50 A1 Unit 1: Non Classified Electrical Building Drawing number Rev Drawing title Scale Paper size HINK-A2-HF-01-GP-030 02 Roof Plan 1:100 A1 HINK-A2-HF-01-GE-001 02 South Elevation 1:100 A1 HINK-A2-HF-01-GE-002 02 North and East Elevations 1:100 A1 HINK-A2-HF-01-DT-001 02 Part Elevation Detail 1:50 A1 Unit 1: Gas Insulated Switch Gear / Main Transformer / Unit Transformer / Auxiliary Transformer Drawing number Rev Drawing title Scale Paper size HINK-A2-HT-01-GP-003 01 Roof 1:200 A1 HINK-A2-HT-01-GE-001 01 Elevations 1:200 A1 HINK-A2-HT-01-DT-001 01 Part Elevation Detail 1:50 A1 Unit 1: Hydrazine Storage Drawing number Rev Drawing title Scale Paper size HINK-A2-SIR-01-GA-001 01 Roof Plan and Elevations 1:100 A1 Conventional Island (Unit 2) Unit 2: Turbine Hall Drawing number Rev Drawing title Scale Paper size HINK-A1-HM-02-GA-006 02 Roof Plan, North and South Elevations 1:200 A0 HINK-A1-HM-02-GE-001 02 West and East Elevations 1:200 A0 HINK-A1-HM-02-DT-001 01 Part Elevation Detail 1:50 A0 Unit 2: Sky Bridges Drawing number Rev Drawing title Scale Paper size HINK-A1-BR-02-GP-010 01 Roof Plan 1:100 A1 HINK-A1-BR-02-GE-001 01 North and South Elevations 1:100 A1 HINK-A1-BR-02-GE-002 01 East and West Elevations 1:100 A1 HINK-A1-BR-02-DT-001 01 Part Elevation Detail 1:50 A1 Unit 2: Non Classified Electrical Building Drawing number Rev Drawing title Scale Paper size HINK-A2-HF-02-GP-030 02 Roof Plan (Lev 10.70m) 1:100 A1 HINK-A2-HF-02-GE-001 02 South Elevation 1:100 A1 HINK-A2-HF-02-GE-002 02 North and West Elevations 1:100 A1 HINK-A2-HF-02-DT-001 02 Part Elevation Detail 1:50 A1 Unit 2: Gas Insulated Switch Gear / Main Transformer / Unit Transformer / Auxiliary Transformer Drawing number Rev Drawing title Scale Paper size HINK-A2-HT-02-GP-003 01 Roof 1:200 A1 HINK-A2-HT-02-GE-001 01 Elevations 1:200 A1 HINK-A2-HT-02-DT-001 01 Part Elevation Detail 1:50 A1 Operations Operational Service Centre Drawing number Rev Drawing title Scale Paper size HINK-A1-HB-00-GP-090 01 Roof Plan 1:200 A1 HINK-A1-HB-00-GE-001 01 North and South Elevations 1:200 A1 HINK-A1-HB-00-GE-002 01 East and West Elevations 1:200 A1 HINK-A1-HB-00-DT-001 01 Part Elevation Detail 1:50 A1 Cooling Water Pumphouse and Associated Buildings (Unit 1) Unit 1: Cooling Water Pumphouse / Forebay / Outfall Pond (Surge Chamber) / Filtering Debris Recovery Pit / Service Access Buildings 5 & 7 Drawing number Rev Drawing title Scale Paper size HINK-A2-HP-01-GP-030 02 Roof Plan 1:200 A0 HINK-A2-HP-01-GE-001 02 Elevations 1:200 A0 HINK-A2-HP-01-DT-001 02 Part Elevation Detail 1:50 A0 Unit 1: Fire-Fighting Water Building Drawing number Rev Drawing title Scale Paper size HINK-A2-HOJ-01-GA-003 02 Roof Plan and Elevations 1:200 A1 HINK-A2-HOJ-01-DT-001 02 Part Elevation Detail 1:50 A1 Discharge Shaft (Units 1 & 2) Drawing number Rev Drawing title Scale Paper size HINK-A2-HCT-00-GA-001 01 Roof Plan & Elevations 1:100 A1 Cooling Water Pumphouse and Associated Buildings (Unit 2) Unit 2: Cooling Water Pumphouse / Forebay / Outfall Pond (Surge Chamber) / Filtering Debris Recovery Pit / Service Access Buildings 6 & 8 Drawing number Rev Drawing title Scale Paper size HINK-A2-HP-02-GP-030 02 Roof Plan 1:200 A0 HINK-A2-HP-02-GE-001 02 Elevations 1:200 A0 HINK-A2-HP-02-DT-001 02 Part Elevation Detail 1:50 A0 Unit 2: Fire-Fighting Water Building Drawing number Rev Drawing title Scale Paper size HINK-A2-HOJ-02-GA-003 02 Roof Plan and Elevations 1:200 A1 HINK-A2-HOJ-02-DT-001 02 Part Elevation Detail 1:50 A1 Remaining Balance of Plant and Other Plant (Unit 1) Unit 1: Hydrogen Storage Drawing number Rev Drawing title Scale Paper size HINK-A2-HZH-01-GA-002 02 Roof Plan and Elevations 1:100 A1 Unit 1: Oxygen Storage Drawing number Rev Drawing title Scale Paper size HINK-A2-HZO-01-GA-002 01 Roof Plan and Elevations 1:100 A1 Remaining Balance of Plant and Other Plant (Unit 2) Unit 2: Hydrogen Storage Drawing number Rev Drawing title Scale Paper size HINK-A2-HZH-02-GA-002 02 Roof Plan & Elevations 1:100 A1 Unit 2: Oxygen Storage Drawing number Rev Drawing title Scale Paper size HINK-A2-HZO-02-GA-002 01 Roof Plan and Elevations 1:100 A1 Remaining Balance of Plant and Other Plant (Shared Between both Units) Demineralisation Station Drawing number Rev Drawing title Scale Paper size HINK-A2-HY-00-GP-030 02 Roof Plan 1:100 A1 HINK-A2-HY-00-GE-001 02 North and South Elevations 1:100 A1 HINK-A2-HY-00-GE-002 02 East and West Elevations 1:100 A1 HINK-A2-HY-00-DT-001 02 Part Elevation Detail 1:50 A1 Auxiliary Boilers Drawing number Rev Drawing title Scale Paper size HINK-A2-HVB-00-GA-004 01 Roof Plan 1:100 A1 HINK-A2-HVB-00-GE-001 01 Elevations 1:100 A1 HINK-A2-HVB-00-DT-001 01 Part Elevation Detail 1:50 A1 Chemical Products Storage Drawing number Rev Drawing title Scale Paper size HINK-A2-HZC-00-GA-001 01 Roof Plan and Elevations 1:100 A1 HINK-A2-HZC-00-DT-001 01 Part Elevation Detail 1:50 A1 Sewage Treatment Plant Drawing number Rev Drawing title Scale Paper size HINK-A2-STP-00-GA-001 01 Plans and Elevations 1:100 A1 Conventional Island Water Storage Tank – A Drawing number Rev Drawing title Scale Paper size HINK-A2-SER-01-GA-002 01 Roof Plan and East Elevation 1:200 A1 Conventional Island Water Storage Tank – B Drawing number Rev Drawing title Scale Paper size HINK-A2-SER-02-GA-002 01 Roof Plan and East Elevation 1:200 A1 Nuclear Island Water Storage Tank Drawing number Rev Drawing title Scale Paper size HINK-A2-SED-00-GA-002 01 Roof Plan and South and East Elevations 1:100 A1 Degassed Water Storage Tanks Drawing number Rev Drawing title Scale Paper size HINK-A2-REA-00-GA-001 01 Roof Plan & Elevations 1:200 A1 Fuel Waste and Storage Interim Spent Fuel Store Drawing number Rev Drawing title Scale Paper size HINK-A2-HHK-00-GP-000 01 Plan 1:200 A0 HINK-A2-HHK-00-GE-001 01 North and South Elevations 1:200 A0 HINK-A2-HHK-00-GE-002 01 East and West Elevations 1:200 A0 Access Control Building Drawing number Rev Drawing title Scale Paper size HINK-A2-HUD-00-GA-001 01 Plans and Elevations 1:100 A1 Intermediate Level Waste Interim Storage Facility Drawing number Rev Drawing title Scale Paper size HINK-A2-HHI-00-GA-002 01 Roof Plan and Elevations 1:200 A0 HINK-A2-HHI-00-DT-001 01 Part Elevation Detail 1:50 A0 Ancillary, Office and Storage Main Access Control Building Drawing number Rev Drawing title Scale Paper size HINK-A2-HU-00-GP-010 01 Roof Plan 1:100 A1 HINK-A2-HU-00-GE-001 01 Elevations 1:100 A1 HINK-A2-HU-00-DT-001 01 Part Elevation Detail 1:50 A1 Entry Relay Building Drawing number Rev Drawing title Scale Paper size HINK-A2-ERB-00-GA-002 01 Roof Plan and Elevations 1:100 A1 HINK-A2-ERB-00-DT-001 01 Part Elevation Detail 1:50 A1 Off-site Vehicle Search Area Drawing number Rev Drawing title Scale Paper size HINK-A2-VSA-00-GA-001 01 Roof Plan and Elevations 1:50 A1 Auxiliary Administration Centre Drawing number Rev Drawing title Scale Paper size HINK-A2-HUC-00-GP-020 02 Roof Plan 1:100 A1 HINK-A2-HUC-00-GE-001 02 North and South Elevations 1:100 A1 HINK-A2-HUC-00-GE-002 02 East and West Elevations 1:100 A1 HINK-A2-HUC-00-DT-001 02 Part Elevation Detail 1:50 A1 EDF Site Offices Drawing number Rev Drawing title Scale Paper size HINK-A2-HAO-00-GE-001 02 Roof & Elevations 1:200 A1 HINK-A2-HAO-00-DT-001 02 Part Elevation Detail 1:50 A1 Garage for Handling Facilities Drawing number Rev Drawing title Scale Paper size HINK-A2-HBG-00-GP-010 01 Roof Plan 1:100 A1 HINK-A2-HBG-00-GE-001 01 Elevations 1:100 A1 HINK-A2-HBG-00-DT-001 01 Part Elevation Detail 1:50 A1 Oil and Grease Storage and Oil Ancillary Building Drawing number Rev Drawing title Scale Paper size HINK-A2-HOG-00-GA-002 01 Roof Plan 1:100 A1 HINK-A2-HOG-00-GE-001 01 North and South Elevations 1:100 A1 HINK-A2-HOG-00-GE-002 01 East and West Elevations 1:100 A1 HINK-A2-HOG-00-DT-001 01 Part Elevation Detail 1:50 A1 AREVA Warehouse Drawing number Rev Drawing title Scale Paper size HINK-A2-HBW-00-GP-010 01 Roof Plan 1:200 A1 HINK-A2-HBW-00-GE-001 01 Elevations 1:200 A1 HINK-A2-HBW-00-DT-001 01 Part Elevation Detail 1:50 A1 Meteorological Station Drawing number Rev Drawing title Scale Paper size HINK-A2-HSM-00-GA-002 01 Roof Plan and Elevations 1:50 A1 Outage Access Control Building Drawing number Rev Drawing title Scale Paper size HINK-A2-TU1-00-GA-002 01 Roof Plan and Elevations 1:100 A1 HINK-A2-TU1-00-DT-001 01 Part Elevation Detail 1:50 A1 Contaminated Tools Storage Drawing number Rev Drawing title Scale Paper size HINK-A2-HHC-01-GA-002 02 Roof Plan and Elevations 1:200 A1 HINK-A2-HHC-01-DT-001 02 Part Elevation Detail 1:50 A1 Conventional Waste Storage Drawing number Rev Drawing title Scale Paper size HINK-A2-CWS-00-GA-002 01 Roof Plan and Elevations 1:200 A1 Transit Area for Very Low Level Waste and Low Level Waste Drawing number Rev Drawing title Scale Paper size HINK-A2-HHL-00-GE-001 01 Elevations 1:100 A1 Raw Water and Potable Water Supply Drawing number Rev Drawing title Scale Paper size HINK-A2-HOR-00-GA-001 02 Roof Plan 1:100 A0 HINK-A2-HOR-00-GA-002 02 Elevations 1:100 A0 HINK-A2-HOR-00-DT-001 02 Part Elevation Detail 1:50 A1 Emergency Response Store Drawing number Rev Drawing title Scale Paper size HINK-A2-HHE-00-GA-001 01 Roof Plan & Elevations 1:200 A1 HINK-A2-HHE-00-DT-001 01 Part Elevation Detail 1:50 A1 Services Ventilation Building Drawing number Rev Drawing title Scale Paper size HINK-A2-HGM-00-GA-001 01 Roof Plan & Elevations 1:100 A1 Public and Training Simulator Building / Training Centre Drawing number Rev Drawing title Scale Paper size HINK-A1-HBS-00-GP-020 01 Roof Plan 1:200 A1 HINK-A1-HBS-00-GE-001 01 Elevations 1:200 A1 HINK-A1-HBS-00-DT-001 01 Part Elevation Detail 1:50 A1 Public Information Centre Drawing number Rev Drawing title Scale Paper size HINK-A1-PIC-00-GP-040 01 Roof Plan 1:100 A1 HINK-A1-PIC-00-GE-001 01 North and West Elevations 1:100 A1 HINK-A1-PIC-00-GE-002 01 South and East Elevations 1:100 A1 HINK-A1-PIC-00-DT-001 01 Part Elevation Detail 1:50 A1 National Grid Substation Drawing number Rev Drawing title Scale Paper size HINK-A2-SS-00-GP-010 01 Roof Plan 1:200 A0 HINK-A2-SS-00-GE-001 01 Elevations 1:200 A0 HINK-A2-SS-00-DT-001 01 Part Elevation Detail 1:50 A0 Other Site Structures Sea Wall (Incorporating Coastal Footpath) Drawing number Rev Drawing title Scale Paper size HINK-A2-HSW-00-GA-001 01 Plans 1:500 A0 HINK-A2-HSW-00-GA-002 01 North Elevation 1:50 A0 HINK-A2-HSW-00-GA-003 01 Detail Plans and Elevations 1:50 A0 HINK-A2-HSW-00-GA-004 01 Detail Plan and Elevation 1:100 A0 EDF Energy Pylons Drawing number Rev Drawing title Scale Paper size HINK-A1-PL-00-GA-001 01 Location Plan, Plans, Elevations and Axonometric Various A1 Highways Plans Drawing number Rev Drawing title Scale Paper size HPC-GEN124-RI-RFC-DRW-000045 01 Northern Roundabout Proposed Layout 1:500 A1 HPC-GEN124-RI-RFC-DRW-000046 01 Vehicle Search Area Layby and Turning Head Proposed Layout 1:250 A1 HPC-GEN124-RI-RFC-DRW-000047 01 Southern Roundabout Proposed Layout During Operation 1:500 A1 HPC-GEN124-RI-RFC-DRW-000048 01 Southern Roundabout Proposed Layout During Construction 1:500 A1 HPC-GEN124-RI-RFC-DRW-000049 01 Emergency Access Road Junction with Existing Highway Proposed Layout 1:250 A1 Site Preparation Plans Drawing number Rev Drawing title Scale Paper size HPCSPW002a Rev1 01 Site Layout Plan 1:3500 A1 HPCSPW002b 00 Beach Access Road Plan and Cross Sections 1:250 / 1:50 A1 HPCSPW004 Rev1 01 Planning Application Fencing Arrangement (Sheet 1 of 3) 1:3500 A1 HPCSPW005 Rev1 01 Fencing Enlarged Detail West (Sheet 2 of 3) 1:1500 A1 HPCSPW006 Rev1 01 Fencing Enlarged Detail East (Sheet 3 of 3) 1:1500 A1 HPCSPW007 Rev1 01 Indicative Earthworks Cut and Fill Arrangement 1:3500 A1 HPCSPW008 00 Early Works Water Management Zone 1:2500 A1 HPCSP009 Rev1 01 Surface Water Catchment Area Overall General Arrangement 1:3000 A1 HPCSPW010 00 Arrangement of Construction Drainage Outfall to Foreshore 1:75 A1 HPCSPW011 Rev1 01 Surface Water Drainage Holford Stream Culvert 1:1500 / 1:150 A1 HPCSPW012a 00 Deep Water Drainage Arrangement 1:2000 / 1:100 A1 HPCSPW012b 00 Deep Water Arrangement Spine Drain Sections A and B 1:200 A1 HPCSPW012c 00 Deep Water Assessment Spine Drain Sections C 1:200 A1 HPCSPW013b 00 Typical Cross Section Through Haul Road 1:50 A1 HPCSPW014 00 11kv Sub Station Plan and Elevations 1:100 A1 HPCSPW015 00 Raw Water Reservoir Plans and Sections 1:150 A1 HPCSPW016 Rev1 01 Surface Water Drainage in the Built Development Areas 1:1750 A1 HPCSPW017 00 Site Access Control Arrangement, Floor and Elevation 1:50 A1 HPCSPW019 Rev1 01 Landscape Proposal Plan 1:5000 A1 HPCSPW022 00 Proposed Sewage Treatment Plant – Plans and Sections 1:100 A1 HPCSPW023a 00 Existing and Reinstated Ground Level Cross Sections 1:2500 / 1:500 A1 HPCSPW023b 00 Earthworks Platforms Cross Sections 1:2500 / 1:500 A1 HPCSPW025a Rev2 02 Tree and Hedgerow Retention and Removal 1:4000 A1 HPCSPW025b Rev1 01 Proposed Advanced Planting, Plan 1:1000 A1 HPCSPW026 00 Primary and Secondary Access Tracks 1:3500 A1 HPCSPW027 00 NW Boundary Mitigation During Construction Cross Sections A and B 1:200 A1 HPCSPW028 00 NW Boundary Mitigation During Construction Cross Sections C and D 1:200 A1 HPCSPW029 00 NW Boundary Mitigation During Construction Planting Plan 1:750 A1 ”