  "url": "https://openlegislation.uk/hydrocarbon-oil-duties-reliefs-for-electricity-generation-amendments-for-carbon-price-support-regulations-2015/regulation-5",
  "json_url": "https://openlegislation.uk/hydrocarbon-oil-duties-reliefs-for-electricity-generation-amendments-for-carbon-price-support-regulations-2015/regulation-5.json",
  "legislation": "uksi/2015/943",
  "legislation_title": "The Hydrocarbon Oil Duties (Reliefs for Electricity Generation) (Amendments for Carbon Price Support) Regulations 2015",
  "legislation_url": "https://openlegislation.uk/hydrocarbon-oil-duties-reliefs-for-electricity-generation-amendments-for-carbon-price-support-regulations-2015",
  "path": "regulation/5",
  "kind": "regulation",
  "number": "5",
  "heading": "Amendments to the Hydrocarbon Oil Duties (Reliefs for Electricity Generation) Regulations 2005",
  "text": "After Schedule 2 insert—\n“SCHEDULE 3\nFUELS REFERABLE TO THE PRODUCTION OF NON-QUALIFYING ELECTRICTY IN A COMBINED HEAT AND POWER STATION\nRegulation 10(8)\n1. The extent to which a quantity of qualifying oil or qualifying bioblend (“input fuels”) is referable to the production of non-qualifying electricity in a combined heat and power station is to be determined in accordance with paragraphs 2 to 5.\n2. Calculate the total quantity of input fuels referable to the production of electricity in accordance with the following formula—\n( TFI− QHO ηh,ref )×( 1− MO TPO ) Where—\nTFI is the CHP Total Fuel Input for the station specified on the CHPQA certificate relating to the relevant annual operation.\nQHO is the CHP Qualifying Heat Output for the station specified on the CHPQA certificate relating to the relevant annual operation.\nηh,ref is the reference boiler heat efficiency, taken here to be 81%.\nMO is Mechanical Output, which is the amount which is the amount of energy in megawatt-hours (electrical) (MWhe) generated by the station in the relevant annual operation that is used to drive a mechanical load (such as a pump, fan or compressor) through direct coupling, without the use of electricity.\nTPO is the CHP Total Power Output for the station specified on the CHPQA certificate relating to the relevant annual operation.\n3. Calculate the total quantity of input fuels referable to the production of non–qualifying electricity in accordance with the following formula—\nQ×( 1− ES TPO−MO ) Where—\nQ is the quantity of input fuels referable to the production of electricity calculated in accordance with paragraph 2.\nES (which must not exceed the QPO) is the amount of qualifying electricity in megawatt-hours generated by the station in the relevant annual operation.\nQPO is the CHP Qualifying Power Output for the station specified on the CHPQA certificate relating to the relevant annual operation.\nTPO and MO have the meaning given in paragraph 2.\n4. Calculate the percentage of input fuels referable to the production of non-qualifying electricity in accordance with the following formula—\n( R TFI )×100 Where—\nR is the quantity of input fuels referable to the production of non-qualifying electricity calculated in accordance with paragraph 3.\nTFI has the meaning given in paragraph 4.\n5. Apply the percentage calculated in accordance with paragraph 3 to the quantity of input fuels used to generate outputs of the station.”.",
  "extent": null,
  "status": null,
  "version": "current",
  "annotations": [],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/uksi/2015/943/regulation/5",
    "retrieved_at": "2026-10-28T23:39:38.050993+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}