# The Lawnmowers (Harmonization of Noise Emission Standards) Regulations 1992, ARTIFICIAL FLOORING


Mineral fibre of thickness 20 mm, airflow resistance 11 kNs/m4 and density 25 kg/m3.
For convenience the artificial flooring can be built of abutting panels (see Figure 1 of this Annex).
The cut edges of the chipboard are to be made non-absorbtive and to be protected against moisture. This can be done by applying a coat of plastic paint.
The outsides are bordered by aluminium U-sections of size 3 × 20 mm. In general, these panels come in two types:
(A) panels not to be loaded;
(B) panels to carry the lawnmower and the test personnel.
On the panels mentioned under (B) aluminium T-sections size 3 × 20 mm are mounted as spacers (see Figure 1 of this Annex).
The prepared boards are then covered with the absorbtive material cut to size.
The panels mentioned under (A) are covered with a wire mesh with a wire thickness of 0.8 mm and a mesh width of 10 mm (aviary wire).
The panels under (B) are covered with wire grating of corrugated steel wire with a diameter of 3.1 mm and a mesh width of 30 mm.
These wire covers are fastened to the aluminium U-sections.

---
Source: https://www.legislation.gov.uk/uksi/1992/168/schedule/3/part/1/crossheading/artificial-flooringn2 (the official version)
Page: https://openlegislation.uk/lawnmowers-harmonization-of-noise-emission-standards-regulations-1992/schedule-3/part-1/crossheading-artificial-flooringn2
Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives.