# The Lifting Plant and Equipment (Records of Test and Examination etc.) Regulations 1992, Paragraph 5


Details of any defect found (especially in the following—
(a) enclosure or hoistway or liftway;
(b) landing gates and cage gate(s);
(c) interlocks on the landing gates and cage gate(s);
(d) other gate fastenings;
(e) cage or platform and fittings, cage guides, buffers, interior of the hoistway or liftway;
(f) over-running devices;
(g) suspension ropes or chains, and their attachments;
(h) safety gear, ie arrangements for preventing fall of platforms or cage;
(i) brakes;
(j) worm or spur gearing;
(k) other electrical equipment;
(l) other parts); and
where appropriate, a statement of the time by when each defect shall be rectified.

---