  "text": "The distance between a store and—\n(a) any minor road or railway line shall be half; and\n(b) any footpath, footway, lightly-used road or waterway shall be one-third,\nthe distance shown in column 2 of the Table corresponding to the quantity of explosives shown in column 1 of the Table.\nTABLE 1\nHAZARD TYPE 1 EXPLOSIVE IN A BRICK-BUILT MOUNDED STORE\n1\n2\n3\n4\n5\n6\nQuantity of explosives (kilograms)\nLow density distance (metres)\nHigh density distance (metres)\nVulnerable building distance (metres)\nReference zone radius (metres)\nMaximum number of dwellings in reference zone\n0.1–25\n101\n—\n101\n—\n—\n25–50\n107\n—\n107\n—\n—\n50–75\n112\n—\n112\n—\n—\n75–100\n118\n—\n118\n—\n—\n100–150\n128\n142\n128\n257\n81\n150–200\n139\n156\n139\n278\n96\n200–300\n161\n180\n161\n322\n128\n300–400\n183\n—\n183\n—\n—\n400–450\n193\n—\n193\n—\n—\n450–500\n204\n—\n204\n—\n—\n500–600\n204\n—\n216\n—\n—\n600–700\n204\n231\n238\n408\n206\n700–800\n204\n238\n260\n408\n206\n800–900\n204\n245\n280\n408\n206\n900–1000\n204\n250\n300\n408\n206\n1000–1100\n204\n255\n319\n408\n206\n1100–1200\n204\n259\n337\n408\n206\n1200–1300\n204\n263\n354\n408\n206\n1300–1400\n204\n266\n370\n408\n206\n1400–1500\n204\n269\n386\n408\n206\n1500–1600\n204\n272\n402\n408\n206\n1600–1700\n208\n274\n416\n416\n214\n1700–1800\n215\n277\n431\n431\n229\n1800–1900\n222\n279\n444\n444\n244\n1900–2000\n229\n281\n458\n458\n259\nTABLE 2\nHAZARD TYPE 1 EXPLOSIVE IN A BRICK-BUILT UNMOUNDED STORE\n1\n2\n3\nQuantity of explosives (kilograms)\nLow density distance (metres)\nVulnerable building distance (metres)\n0.1–25\n141\n141\n25–50\n160\n160\n50–75\n180\n180\n75–100\n199\n199\n100–150\n230\n230\n150–200\n256\n256\n200–300\n293\n293\n300–400\n320\n320\n400–450\n331\n331\n450–500\n340\n340\n500–600\n355\n355\n600–700\n367\n367\n700–800\n377\n377\n800–900\n385\n385\n900–1000\n392\n392\n1000–1100\n398\n398\n1100–1200\n403\n403\n1200–1300\n408\n408\n1300–1400\n412\n412\n1400–1500\n415\n415\n1500–1600\n418\n418\n1600–1700\n421\n421\n1700–1800\n424\n431\n1800–1900\n426\n444\n1900–2000\n428\n458\nTABLE 3\nHAZARD TYPE 1 EXPLOSIVE IN A METAL-BUILT MOUNDED STORE\n1\n2\n3\n4\n5\n6\nQuantity of explosives (kilograms)\nLow density distance (metres)\nHigh density distance (metres)\nVulnerable building distance (metres)\nReference zone radius (metres)\nMaximum number of dwellings in reference zone\n0.1–25\n34\n45\n40\n68\n6\n25–50\n37\n45\n48\n74\n7\n50–75\n40\n45\n54\n80\n8\n75–100\n43\n48\n66\n86\n9\n100–150\n49\n55\n86\n97\n12\n150–200\n54\n62\n104\n109\n15\n200–300\n68\n76\n136\n136\n23\n300–400\n83\n—\n165\n—\n—\n400–450\n89\n—\n178\n—\n—\n450–500\n96\n—\n191\n—\n—\n500–600\n108\n—\n216\n—\n—\n600–700\n119\n—\n238\n—\n—\n700–800\n130\n—\n260\n—\n—\n800–900\n140\n—\n280\n—\n—\n900–1000\n150\n—\n300\n—\n—\n1000–1100\n159\n—\n319\n—\n—\n1100–1200\n168\n—\n337\n—\n—\n1200–1300\n177\n—\n354\n—\n—\n1300–1400\n185\n—\n370\n—\n—\n1400–1500\n193\n—\n386\n—\n—\n1500–1600\n201\n—\n402\n—\n—\n1600–1700\n208\n—\n416\n—\n—\n1700–1800\n215\n—\n431\n—\n—\n1800–1900\n222\n—\n444\n—\n—\n1900–2000\n229\n—\n458\n—\n—\nTABLE 4\nHAZARD TYPE 1 EXPLOSIVE IN A METAL-BUILT UNMOUNDED STORE WITH NO DETONATOR ANNEX ATTACHED\n1\n2\n3\n4\n5\n6\nQuantity of explosives (kilograms)\nLow density distance (metres)\nHigh density distance (metres)\nVulnerable building distance (metres)\nReference zone radius (metres)\nMaximum number of dwellings in reference zone\n0.1–10\n23\n30\n40\n46\n3\n10–20\n29\n35\n42\n57\n4\n20–30\n33\n39\n44\n65\n5\n30–40\n36\n42\n46\n71\n6\n40–50\n38\n44\n48\n76\n7\n50–60\n40\n46\n48\n80\n8\n60–70\n42\n48\n52\n84\n9\n70–80\n43\n50\n57\n87\n9\n80–90\n44\n52\n61\n89\n10\n90–100\n45\n55\n66\n91\n10\n100–110\n46\n57\n70\n93\n11\n110–120\n47\n59\n74\n95\n11\n120–130\n48\n62\n78\n97\n12\n130–140\n49\n64\n82\n98\n12\n140–150\n50\n66\n86\n100\n12\n150–160\n51\n68\n90\n102\n13\n160–170\n52\n71\n93\n104\n13\n170–180\n53\n73\n97\n106\n14\n180–190\n54\n75\n101\n108\n14\n190–200\n55\n78\n104\n110\n15\n200–300\n68\n101\n136\n136\n23\n300–400\n83\n124\n165\n165\n34\n400–450\n89\n135\n178\n178\n39\n450–500\n96\n138\n191\n191\n45\n500–600\n108\n144\n216\n216\n57\n600–700\n119\n150\n238\n238\n70\n700–800\n130\n156\n260\n260\n83\n800–900\n140\n162\n280\n280\n97\n900–1000\n150\n168\n300\n300\n111\n1000–1100\n159\n168\n319\n319\n111\n1100–1200\n168\n—\n337\n—\n—\n1200–1300\n177\n—\n354\n—\n—\n1300–1400\n185\n—\n370\n—\n—\n1400–1500\n193\n—\n386\n—\n—\n1500–1600\n201\n—\n402\n—\n—\n1600–1700\n208\n—\n416\n—\n—\n1700–1800\n215\n—\n431\n—\n—\n1800–1900\n222\n—\n444\n—\n—\n1900–2000\n229\n—\n458\n—\n—\nTABLE 5\nHAZARD TYPE 1 EXPLOSIVE IN A METAL-BUILT UNMOUNDED STORE WITH A DETONATOR ANNEX ATTACHED\n1\n2\n3\n4\n5\n6\nQuantity of explosives (kilograms)\nLow density distance (metres)\nHigh density distance (metres)\nVulnerable building distance (metres)\nReference zone radius (metres)\nMaximum number of dwellings in reference zone\n0.1–25\n38\n53\n54\n74\n11\n25–50\n43\n53\n54\n86\n11\n50–75\n48\n60\n54\n96\n11\n75–100\n53\n77\n66\n106\n14\n100–150\n63\n110\n86\n127\n20\n150–200\n74\n143\n104\n147\n27\n200–300\n94\n209\n136\n188\n44\n300–400\n115\n275\n165\n229\n65\n400–450\n125\n308\n178\n250\n77\n450–500\n128\n309\n191\n257\n81\n500–600\n135\n311\n216\n270\n90\n600–700\n142\n312\n238\n283\n99\n700–800\n148\n314\n260\n297\n109\n800–900\n155\n316\n280\n310\n119\n900–1000\n162\n318\n300\n324\n129\n1000–1100\n169\n319\n319\n337\n140\n1100–1200\n175\n321\n337\n350\n152\n1200–1300\n182\n323\n354\n364\n163\n1300–1400\n189\n325\n370\n377\n176\n1400–1500\n195\n326\n386\n391\n188\n1500–1600\n202\n328\n402\n404\n202\n1600–1700\n209\n330\n416\n417\n215\n1700–1800\n215\n332\n431\n431\n229\n1800–1900\n222\n333\n444\n444\n244\n1900–2000\n229\n335\n458\n458\n259\nTABLE 6\nHAZARD TYPE 2 EXPLOSIVE, SOME OR ALL ITEMS BEING OF MORE THAN 0.7 KILOGRAMS NET MASS\n1\n2\n3\nQuantity of explosives (kilograms)\nLow density distance (metres)\nVulnerable building distance (metres)\n0.1–25\n45\n90\n25–50\n88\n176\n50–75\n108\n216\n75–100\n129\n238\n100–150\n148\n296\n150–200\n168\n336\n200–300\n191\n382\n300–400\n207\n414\n400–450\n213\n426\n450–500\n219\n438\n500–600\n226\n452\n600–700\n233\n466\n700–800\n240\n480\n800–900\n248\n496\n900–1000\n256\n512\n1000–1100\n259\n518\n1100–1200\n262\n524\n1200–1300\n266\n532\n1300–1400\n270\n540\n1400–1500\n274\n548\n1500–1600\n278\n556\n1600–1700\n282\n564\n1700–1800\n286\n572\n1800–1900\n288\n576\n1900–2000\n292\n592\nTABLE 7\nHAZARD TYPE 2 EXPLOSIVE, EVERY ITEM BEING OF 0.7 KILOGRAMS NET MASS OR LESS\n1\n2\n3\nQuantity of explosives (kilograms)\nLow density distance (metres)\nVulnerable building distance (metres)\n0.1–25\n37\n76\n25–50\n43\n86\n50–75\n47\n94\n75–100\n51\n102\n100–150\n56\n112\n150–200\n60\n120\n200–300\n66\n132\n300–400\n71\n142\n400–450\n73\n146\n450–500\n74\n148\n500–600\n76\n152\n600–700\n78\n158\n700–800\n81\n162\n800–900\n84\n164\n900–1000\n87\n174\n1000–1100\n88\n176\n1100–1200\n89\n178\n1200–1300\n90\n180\n1300–1400\n91\n182\n1400–1500\n92\n184\n1500–1600\n94\n188\n1600–1700\n95\n190\n1700–1800\n97\n194\n1800–1900\n99\n198\n1900–2000\n101\n202\nTABLE 8\nHAZARD TYPE 3 EXPLOSIVE\n1\n2\nQuantity of explosives (kilograms)\nLow density distance (metres)\n0.1–25\n—\n25–50\n23\n50–75\n25\n75–100\n29\n100–150\n33\n150–200\n37\n200–300\n42\n300–400\n47\n400–450\n47\n450–500\n50\n500–600\n51\n600–700\n53\n700–800\n54\n800–900\n55\n900–1000\n63\n1000–1100\n70\n1100–1200\n71\n1200–1300\n72\n1300–1400\n73\n1400–1500\n74\n1500–1600\n75\n1600–1700\n76\n1700–1800\n78\n1800–1900\n79\n1900–2000\n80\nTABLE 9\nHAZARD TYPE 4 EXPLOSIVE\n1\n2\nQuantity of explosives (kilograms)\nLow density distance (metres)\n0.1–250\n—\n250–300\n1\n300–340\n2\n340–370\n3\n370–400\n4\n400–450\n5\n450–500\n6\n500–550\n7\n550–600\n8\n600–650\n9\n650–700\n10\n700–750\n11\n750–800\n12\n800–900\n13\n900–950\n14\n950–1000\n15\n1000–1100\n16\n1100–1150\n17\n1150–1200\n18\n1200–1300\n19\n1300–1350\n20\n1350–1400\n21\n1400–1450\n22\n1450–1550\n23\n1550–1600\n24\n1600–1650\n25\n1650–1700\n26\n1700–1800\n27\n1800–1850\n28\n1850–1900\n29\n1900–2000\n30",
  "extent": "N.I.",
  "status": null,
  "version": "current",
  "annotations": [
    {
      "type": "I",
      "label": "I1",
      "text": "Sch. 1 para. 6 in operation at 1.12.2006, see reg. 1"
    }
  ],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/nisr/2006/425/schedule/1/paragraph/6",
    "retrieved_at": "2026-10-29T01:44:33.852375+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}