Regulation 5 Amendments to the Measuring Equipment (Intoxicating Liquor) Regulations 1983
After regulation 11 insert the following—
“11A.Subject to Regulation 11B, every item of measuring equipment shall be tested by an inspector or approved verifier in accordance with the methods set out in Regulation 12.
11B.(1)Where a group of items of fixed chamber measuring equipment of the same design, the same manufacture and designed to deliver the same nominal quantity is submitted for testing, and the conditions specified in paragraph (2) are satisfied with respect to the group, the testing may, at the request of the person submitting the equipment, be confined to a number of items of fixed chamber measuring equipment as determined and selected in accordance with paragraph (3).
(2)The conditions referred to in paragraph (1) are—
(a)the group is clearly identifiable and consists of items of fixed chamber measuring equipment produced in a single homogenous production run where the items are manufactured in the same place during a period or periods in which the conditions under which the items are manufactured do not alter; and
(b)the group is accompanied by records of the production process and of any subsequent action taken by the manufacturer which are adequate to show that the items in the group are likely to fall within the prescribed limits of error.
(3)The number of items of fixed chamber measuring equipment referred to in paragraph (1) shall be determined and the items shall be selected in accordance with the sampling procedures referred to in paragraph (4)(a) using samples which the inspector or the approved verifier considers to be representative.
(4)The sample of items of fixed chamber measuring equipment selected in accordance with paragraph (3) shall be tested –
(a)in accordance with the British Standard specification for sampling procedures for inspection by attributes BS6001:2006f1 or an International Standard which provides sampling procedures for inspection by attributes to an acceptable quality level equivalent to that contained in BS 6001:2006; and
(b)to determine whether the items fall within the prescribed limits of error,
and such test shall provide an acceptable quality level of not more than 1 per cent.
(5)If the sample of items satisfies the test in paragraph (4) (“a satisfactory sample”) then each of the other items of fixed chamber measuring equipment in the group shall be treated as falling within the prescribed limits of error but where there are items in the satisfactory sample which do not satisfy the test in paragraph (4) those items shall not be passed as fit for use for trade.”.
Annotations
Footnotes
- f1
-
ISBN No. 0 580 49315 6, published by the British Standards Institution on 31st October 2006.