  "heading": "Prescribed limits of error",
  "text": "Table 1\nPrescribed limits of error ordinarily applicable on testing for quantities above the minimum delivery of the equipment\nQuantity indicated\nIn relation to passing as fit for use for trade, in excess or in deficiency\nDynamic viscosity ≤1000 mPa.s\nDynamic viscosity >1000 mPa.s\nIn relation to obliteration of the stamp\nDynamic viscosity ≤1000 mPa.s\nDynamic viscosity >1000 mPa.s\nLess than 0.1 L\n2 mL\n4 mL\n4 mL in excess\n2 mL in deficiency\n8 mL in excess\n4 mL in deficiency\nFrom 0.1 L to 0.2 L\n2% of the quantity indicated\n4% of the quantity indicated\n4% in excess\n2% in deficiency\n8 % in excess\n4% in deficiency\nFrom 0.2 L to 0.4 L\n4 mL\n8 mL\n8 mL in excess\n4 mL in deficiency\n16 mL in excess\n8 mL in deficiency\nFrom 0.4 L to 1 L\n1% of the quantity indicated\n2% of the quantity indicated\n2% in excess\n1% in deficiency\n4% in excess\n2% in deficiency\nFrom 1 L to 2 L\n10 mL\n20 mL\n20 mL in excess\n10 mL in deficiency\n40 mL in excess\n20 mL in deficiency\n2 L or more\n0.5% of the quantity indicated\n1% of the quantity indicated\n1% in excess\n0.5% in deficiency\n2% in excess\n1% in deficiency\nTable 2\nPrescribed limits of error ordinarily applicable on testing for quantities equivalent to the minimum delivery of the equipment only\nQuantity indicated\nIn relation to passing as fit for use for trade, in excess or in deficiency\nDynamic viscosity ≤1000 mPa.s\nDynamic viscosity >1000 mPa.s\nIn relation to obliteration of the stamp\nDynamic viscosity ≤1000 mPa.s\nDynamic viscosity >1000 mPa.s\nLess than 0.1 L\n4 mL\n8 mL\n8 mL in excess\n4 mL in deficiency\n16 mL in excess\n8 mL in deficiency\nFrom 0.1 L to 0.2 L\n4% of the quantity indicated\n8% of the quantity indicated\n8% in excess\n4% in deficiency\n16 % in excess\n8% in deficiency\nFrom 0.2 L to 0.4 L\n8 mL\n16 mL\n16 mL in excess\n8 mL in deficiency\n32 mL in excess\n16 mL in deficiency\nFrom 0.4 L to 1 L\n2% of the quantity indicated\n4% of the quantity indicated\n4% in excess\n2% in deficiency\n8% in excess\n4% in deficiency\nFrom 1 L to 2 L\n20 mL\n40 mL\n40 mL in excess\n20 mL in deficiency\n80 mL in excess\n40 mL in deficiency\n2 L or more\n1% of the quantity indicated\n2% of the quantity indicated\n2% in excess\n1% in deficiency\n4% in excess\n2% in deficiency",
  "extent": "E+W+S",
  "status": null,
  "version": "current",
  "annotations": [
    {
      "type": "I",
      "label": "I1",
      "text": "Sch. in force at 4.5.1995, see reg. 1(1)"
    }
  ],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/uksi/1995/1014/schedule",
    "retrieved_at": "2026-10-29T13:11:17.353011+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}