# The Measuring Instruments Regulations 2016, Paragraph 1.1: The flowrate range


The flowrate ran ge is subject to the following conditions:
(i) the flowrate range of a measuring system shall be within the flowrate range of each of its elements, in particular the meter.
(ii) meter and measuring system:
Table 1
Specific measuring system
Characteristic of liquid
Minimum ratio of Qmax: Qmin
Fuel dispensers
Not Liquefied gases
10: 1
Liquefied gases
5: 1
Measuring system
Cryogenic liquids
5: 1
Measuring systems on pipeline and systems for loading ships
All liquids
Suitable for use
All other measuring systems
All liquids
4: 1

---
Source: https://www.legislation.gov.uk/uksi/2016/1153/schedule/1F/paragraph/1.1 (the official version)