# The Merchant Shipping and Fishing Vessels (Health and Safety at Work) (Electromagnetic Fields) Regulations 2016, Chapter: Action levels – non-thermal effects

Extent: E+W+S+N.I.

Table AL5 - ALs for contact currents
Frequency of electromagnetic field in which an object is present
Contact current ALs (Ic)[mA]
up to 2.5 kHz
1.0
2.5 ≤ f < 100 kHz
0.4 f
100 ≤ f ≤ 10,000 kHz
40
NOTES
1 “f” is the frequency expressed in kHz.
2 The ALs are root mean square values.
3 The ALs represent the maximum steady state current created during a continuous contact with an object in an electromagnetic field.
Table AL6 – ALs for static magnetic fields
Potential indirect effect
Magnetic flux density ALs (B0)[mT]
Interference with active implanted medical devices
0.5
Attraction and projectile risk in the fringe field of high field strength sources (> 100 mT)
3
NOTE
The AL for interference with active implanted medical devices represents the maximum field value at any place where a worker may be working.

---
Source: https://www.legislation.gov.uk/uksi/2016/1026/schedule/part/3/chapter/1 (the official version)
Page: https://openlegislation.uk/merchant-shipping-and-fishing-vessels-health-and-safety-at-work-electromagnetic-fields-regulations-2016/schedule/part-3/chapter-1
Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives.