  "url": "https://openlegislation.uk/merchant-shipping-cargo-ship-construction-regulations-1997/regulation-50",
  "json_url": "https://openlegislation.uk/merchant-shipping-cargo-ship-construction-regulations-1997/regulation-50.json",
  "legislation": "uksi/1997/1509",
  "legislation_title": "The Merchant Shipping (Cargo Ship Construction) Regulations 1997",
  "legislation_url": "https://openlegislation.uk/merchant-shipping-cargo-ship-construction-regulations-1997",
  "path": "regulation/50",
  "kind": "regulation",
  "number": "50",
  "heading": "Location and construction of cables Requirements for ships constructed on or after 1st September 1984",
  "text": "(1) All electrical cables external to equipment shall be flame retardant and shall be installed so that their flame retarding or equivalent properties are not impaired. The Certifying Authority may permit installation of cables which do not comply with the foregoing for particular purposes, such as radio frequency cables, where compliance would be impracticable.\n(2) Cables shall be installed and supported in such a manner as to avoid chafing and other damage. All metal sheaths and metal armour of electric cables shall be electrically continuous and shall be earthed except that the Certifying Authority may permit such earthing to be omitted for particular purposes.\n(3) Cables serving emergency services shall not, so far as is practicable, be routed through galleys, laundries, machinery spaces of Category A and their casings or other high risk areas except insofar as it is necessary to provide emergency services in such areas. Cables connecting fire pumps to the emergency switchboard shall be of a fire resistant type where they pass through high fire risk areas.\n(4) Cables serving emergency services shall, where practicable, be installed in such a manner as to preclude them being rendered unserviceable by the effect of a fire in an adjacent space and subsequent heating of the dividing bulkhead.\n(5) The electrical, mechanical, flame retarding and, where applicable, fire resisting properties of the terminations and joints in any conductor shall be at least equivalent to those of the conductor.",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [
    {
      "type": "I",
      "label": "I1",
      "text": "Reg. 50 in force at 11.7.1997, see reg. 1(1)"
    }
  ],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/uksi/1997/1509/regulation/50",
    "retrieved_at": "2026-10-29T12:07:02.970396+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}