OpenLegislation

Regulation 13 Lighting

Original text. Later amendments are not shown.

(1)

In passenger ships all parts of the crew accommodation, except galleys, pantries, laundries, drying rooms, lockers, private and semi-private bathrooms and store rooms, shall wherever reasonably practicable be adequately lit by natural light.

(2)

In ships other than passenger ships—

(a)

subject to paragraph (b) below, all parts of the crew accommodation except galleys, pantries, laundries, drying rooms, lockers, private and semi-private bathrooms and store rooms, shall be adequately lit by natural light; and

(b)

sanitary accommodation and passageways shall wherever reasonably practicable be adequately lit by natural light.

(3)

For the purposes of paragraphs (1) and (2), “adequately lit” means lit by natural light which is bright enough in day time in clear weather to enable a person with normal sight to read an ordinary newspaper in those parts of the room or other space which are available for free movement.

(4)

An electric lighting system shall be installed which is capable of supplying adequate light in all parts of the crew accommodation. Electric lights shall be so arranged as to give maximum benefit to the crew and shall include an electric reading lamp for each bed, fitted with a controlling switch at the head of the bed.

(5)

An efficient alternative lighting system or an alternative supply of electrical power to the system mentioned in paragraph (4) shall be available for use when required in the crew accommodation.

(6)

Any reading light provided in accordance with paragraph (4) shall—

(a)

if it is in a sleeping room, be fitted with a lamp capable of emitting at least 200 lumens; and

(b)

if it is in a hospital ward, be fitted with a lamp capable of emitting at least 400 lumens.

(7)

The electric lighting in any of the following spaces, that is to say, sleeping rooms, day rooms, recreation rooms, rooms for watching films and television, hobbies and games rooms, mess rooms, hospital wards, offices, studies, sanitary accommodation, laundries, drying rooms, dry provision store rooms, cold store rooms, galleys, passageways, companionways and covered deck recreation spaces, shall be treated as adequate for the purposes of this regulation if—

(a)

when the lamps, paintwork and other surface finishes are new, the illuminance in the horizontal plane when measured at the points specified in respect of that space in the Schedule to these Regulations is steady and is maintained, subject to a tolerance of 10 per cent, at the value prescribed in that Schedule in respect of those points; and

(b)

it complies with any other requirements specified in the said Schedule in respect of that space.